Users Guide

The learn cycle recalibrates the battery-integrated circuit so that the controller can determine whether the battery can maintain the
controller cache for the prescribed period in the event of a power loss.
While the learn cycle is in progress, the battery may not be able to maintain the cache during a power loss. If the controller is using Write-
Back Cache policy, then the controller changes to Write-Through Cache policy until the learn cycle completes. The write-through cache
policy writes the data directly to the disk and reduces the risk of data loss in the cache during a power outage.
NOTE: If you have set the controller to Force Write-Back Cache policy, then the cache policy is not changed during the learn
cycle. When using Force Write-Back Cache policy, it is possible for data loss to occur if there is a power outage while the learn
cycle is in progress.
The controller rmware automatically initiates the learn cycle every 90 days. You can, however, delay the start time of the learn cycle for a
further seven days, after which the rmware automatically initiates the learn cycle.
NOTE: The learn cycle cannot be performed while the battery is charging. If either a user or the controller rmware initiates the
learn cycle while the battery is charging, then the battery learn state displays Requested. The learn cycle begins when the
battery is fully charged.
Related link
Initiating The Battery Delay Learn Cycle
Battery Transparent Learn Cycle
The PERC H710 and PERC H810 controllers support Transparent Learn Cycle (TLC), a periodic operation that calculates the charge that is
remaining in the battery to ensure that there is sucient energy. The operation runs automatically, and causes no impact to the system or
controller performance. The controller automatically performs TLC on the battery to calibrate and gauge its charge capacity once every 90
days. The operation can be performed manually, if required.
Initiating The Battery Delay Learn Cycle
Does my controller support this feature? See Supported Features.
The controller rmware automatically initiates the battery learn cycle every 90 days. Although you cannot stop the rmware from running
the learn cycle, you can delay the start time of the learn cycle for up to seven days.
Related link
Starting A Learn Cycle
RAID Controller Batteries
Delay The Battery Learn Cycle
1 Type a numerical value in the Days text box. The value must be within the 0–7 range. The value indicates the number of days for
which you want to delay the battery learn cycle. The learn cycle can be delayed for a maximum of seven days.
2 Type a numerical value in the Hours text box. The value must be within the 0–23 range. The value indicates the number of hours for
which you want to delay the battery learn cycle.
3 Click Apply Changes.
To exit and cancel your changes, click Go Back To Battery Information Page.
RAID Controller Batteries
117