Users Guide
For SAS Controllers
For SAS controllers, you must:
1 Check the alert log for an alert verifying that the system has identied the new disk. You may receive alert 2052 or 2294. For
information on alert messages, see the Server Administrator Messages Reference Guide.
2
Refresh the display by clicking Refresh ( ) or by changing pages.
NOTE: Clicking the Refresh button in the right pane refreshes only the right pane. To view the new physical disk in the left
pane tree view, click the system name displayed at the top of the left pane, or click View > Refresh on the browser.
The new physical disk or physical device is displayed in the tree view after refreshing the display. If the new disk is not displayed,
restart the computer.
Related Information
• If you are replacing a disk that is part of a virtual disk, see Replacing The Disk.
• If you want to include the new disk in a virtual disk, see Virtual Disk Considerations For Controllers
• For more information, see RAID Controller Technology: SATA and SAS
Replacing A Physical Disk Receiving SMART Alerts
Self Monitoring, Analysis and Reporting Technology (SMART) alerts are messages predicting that a disk may fail soon. If a physical disk is
receiving SMART alerts replace the disk. Use the following procedures to replace a disk receiving SMART alerts:
Disk Is Part Of A Redundant Virtual Disk
CAUTION
: To avoid potential data loss, perform a check consistency before removing a physical disk that is receiving SMART
alerts. The check consistency veries that all data is accessible within the redundant virtual disk and uses the redundancy to
repair any bad blocks that may be present. In some circumstances, failure to perform a check consistency can result in data loss.
This may occur, for example, if the physical disk receiving SMART alerts has bad disk blocks and you do not perform a check
consistency before removing the disk.
1 Select the redundant virtual disk that includes the physical disk that is receiving SMART alerts and perform the Check Consistency
task. For more information, see Performing A Check Consistency
2 Select the disk that is receiving SMART alerts and execute the Oine task.
3 Manually remove the disk.
4 Insert a new disk. Make sure that the new disk is the same size or greater in size than the disk you are replacing. On some controllers,
you may not be able to use the additional disk space if you insert a disk with a greater disk space than the one you are replacing. For
more information on disk space considerations, see Virtual Disk Considerations For Controllers.
5 To assign the READY disk to be a hot spare. After you complete this procedure, a rebuild is automatically initiated because the virtual
disk is redundant.
Disk Is Not Part Of A Redundant Virtual Disk
1 Back up data from the virtual disk.
2 Delete the virtual disk.
3 Replace the disk that is receiving SMART alerts.
4 Create a new virtual disk. Make sure that the new virtual disk is the same size or greater in size than the original virtual disk. For
controller-specic information on creating virtual disks, see Virtual Disk Considerations For Controllers.
94