CLI Guide
name=value pair 1 name=value pair 2 Description
NOTE: The OS logging lter
command is applicable when the OS
logging lter component is installed.
attribute=archiveesmlog setting=Enable|Disable
Enabling the command allows you to create
an automatic backup of ESM Logs. After the
backup is created, ESM logs of the Server
Administrator and the SEL entries of
iDRAC/BMC are cleared. The process is
repeated whenever the logs are full.
The backup les are:
Windows: <Install_root>\omsa\log
\omsellog.xml
Linux and ESXi: <Install_root>/var/log/
openmanage/omsellog.xml
NOTE: This command is applicable
only on 10th and 11th generation of
PowerEdge servers. On Dell’s 12th
generation of PowerEdge servers and
later, iDRAC provides capability of
automatic clear of log entries and le
backup. Only latest version of the
backup XML le is available in the
mentioned locations.
attribute=logallsensors setting=Enable|Disable Enabling the command allows you to log all
unmonitored ESM sensor events in to Alert
log, OS log, and generates the SNMP traps.
An example command set only to remove the critical severities is as follows:
omconfig preferences logging attribute=oslogfilter logcrit=false
An example command set to enable the automatic backup of ESM logs.
omconfig preferences logging attribute=archiveesmlog setting=Enable
An example command set to enable the Log All ESM Sensor Events.
omconfig preferences logging attribute=logallsensors setting=Enable
Omcong preferences webserver
Use the omcong preferences webserver command to set the encryption levels of the Server Administrator web server, congure the URL
launch point in the Server Administrator web server environment, and to set the JRE version for the Server Administrator.
The following table displays the name=value pairs you can use with this command:
Omcong
Managing Components Using The Instrumentation Service 97