CLI Guide
When you issue the command and the system sets the values you specify, the following message is displayed:
Voltage probe warning threshold(s) set successfully.
Omcong Preferences
Use the omcong preferences command to set system preferences. Use the command line to specify the user levels to access Server
Administrator and to congure the Active Directory service.
Omcong Preferences Cdvformat
Use the omcong preferences cdvformat to specify the delimiters for separating data elds reported in the custom delimited format. The
valid values for delimiters are: exclamation, semicolon, at, hash, dollar, percent, caret, asterisk, tilde, question, colon, comma, and pipe.
The following example shows how to set the delimiter for separating data elds to asterisk:
omconfig preferences cdvformat delimiter=asterisk
Omcong Preferences Dirservice
Use the omcong preferences dirservice command to congure the Active Directory service. The <productname>oem.ini le is modied
to reect these changes. If the "adproductname" is not present in the <productname>oem.ini le then a <computername>-
<computername> refers to the name of the computer running Server Administrator and <productname> refers to the name of the
product dened in omprv32.ini. For Server Administrator, the product name is "omsa".
Therefore, for a computer named "myOmsa" running Server Administrator, the default name is "myOmsa–omsa". This is the name of Server
Administrator dened in Active Directory by using the snap-in tool. This name must match the name for the application object in Active
Directory in order to nd user privileges.
NOTE
: This command is applicable only on systems running the Windows operating system.
The following table displays the valid parameters for the command:
Table 59. Valid Parameters Of
Omcong Preferences Dirservice
name=value pair Description
prodname=<text> Species the product to which you want to apply the Active Directory conguration changes. prodname refers
to the name of the product dened in omprv32.ini. For Server Administrator, it is "omsa".
enable=<true | false>
true: Enables Active Directory service authentication support and the Active Directory Login option on the
login page.
false: Disables Active Directory service authentication support and the Active Directory Login option on the
login page. If the Active Directory Login option is not present, you can only login to the local machine accounts.
adprodname=<text> Species the name of the product as dened in the Active Directory service. This name links the product with
the Active Directory privilege data for user authentication.
Omcong Preferences Messages
Use the omcong preferences messages command to select the format of alert messages. The default format is traditional, which is
the legacy format.
Omcong
Managing Components Using The Instrumentation Service 95