CLI Guide
– Remote access IP address
– Ambient temperature of the system
– Remote access IPv4 address
– Remote access IPv6 address
• Specify and congure the LCD line number
• View the encryption state report of the LCD
• Congure LCD to indicate an active remote session when the Kernel-based Virtual Machine (KVM) is available
NOTE: You can congure the Power and NMI buttons only if they are present on the system.
The following table displays the valid parameters for the command:
Table 48. Valid Parameters Of Omcong Chassis Frontpanel Or Omcong Mainsystem Frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=<index> NA Species the LCD line number.
cong=none | default | custom NA
• none: Sets the LCD text to none.
• default: Sets the LCD text to default.
• custom: Sets the LCD text to custom.
text=<custom text> NA Sets the custom text for LCD when
cong=custom.
nmibutton=enable | disable NA
• enable: Enables the NMI button on the
system.
• disable: Disables the NMI button on the
system.
powerbutton=enable | disable NA
• true: Enables the Power button on the
system.
• false: Disables the Power button on the
system.
cong=sysname NA Sets the name of the system.
cong=syspower NA Sets the system power information.
cong=servicetag NA Sets the system service tag information.
cong=remoteaccessipv4 NA Sets the remote access IPv4 information.
cong=remoteaccessipv6 NA Sets the remote access IPv6 information.
cong=remoteaccessmac NA Sets the remote access MAC address.
cong=ipv4idrac Sets IPv4 DRAC information.
cong=ipv6idrac Sets IPv6 DRAC information.
cong=macidrac NA Sets the DRAC’s MAC address.
cong=ambienttemp NA Sets the system temperature in centigrade.
security=modify NA Allows you to modify the LCD text.
security=view NA Provides read-only access to the LCD text.
security=disabled NA Provides limited access to the LCD text.
Omcong Managing Components Using The Instrumentation Service 79