CLI Guide
The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists each of the valid parameters as
displayed in the following table:
Table 29. Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
name=value pair Description
cong=additional Reports the current state of IPv4 and IPv6 addresses on iDRAC.
cong=advsol Reports advanced BMC/iDRAC or remote access information on a serial over local area network (LAN)
connection.
cong=nic Reports BMC/iDRAC or remote access information for the LAN.
cong=serial Reports serial port information for BMC or remote access.
cong=serialoverlan Reports BMC/iDRAC or remote access information on a serial over LAN connection.
cong=terminalmode Reports terminal mode settings for the serial port.
cong=user Reports information on BMC/iDRAC or remote access users.
Omreport Chassis Removableashmedia Or Omreport
Mainsystem Removableashmedia
Use the omreport chassis removableashmedia or omreport mainsystem removableashmedia to view the removable ash media details on
the system along with its health status. Type:
omreport chassis removableflashmedia
or
omreport mainsystem removableflashmedia
Server Administrator displays a summary of the system’s removable ash media information.
NOTE
: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.
Depending on the conguration of the system, you may notice the following output:
Table 30. Output status
Removable Flash Media Information
Health : Critical
Internal Dual SD Module Redundancy : Critical
Attribute : Redundancy
Value : Lost
Internal SD Modules Status
Status : OK
Connector Name : System Board SD Status 1
State : Present
Storage Size : 512 MB
Status : OK
Connector Name : System Board SD Status 2
omreport Viewing System Status Using The Instrumentation Service 39