The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists each of the valid parameters as
displayed in the following table:
Table 29. Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
name=value pair Description
cong=additional Reports the current state of IPv4 and IPv6 addresses on iDRAC.
cong=advsol Reports advanced BMC/iDRAC or remote access information on a serial over local area network (LAN)
connection.
cong=nic Reports BMC/iDRAC or remote access information for the LAN.
cong=serial Reports serial port information for BMC or remote access.
cong=serialoverlan Reports BMC/iDRAC or remote access information on a serial over LAN connection.
cong=terminalmode Reports terminal mode settings for the serial port.
cong=user Reports information on BMC/iDRAC or remote access users.
Omreport Chassis Removableashmedia Or Omreport
Mainsystem Removableashmedia
Use the omreport chassis removableashmedia or omreport mainsystem removableashmedia to view the removable ash media details on
the system along with its health status. Type:
omreport chassis removableflashmedia
or
omreport mainsystem removableflashmedia
Server Administrator displays a summary of the system’s removable ash media information.
NOTE
: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.
Depending on the conguration of the system, you may notice the following output:
Table 30. Output status
Removable Flash Media Information
Health : Critical
Internal Dual SD Module Redundancy : Critical
Attribute : Redundancy
Value : Lost
Internal SD Modules Status
Status : OK
Connector Name : System Board SD Status 1
State : Present
Storage Size : 512 MB
Status : OK
Connector Name : System Board SD Status 2
omreport Viewing System Status Using The Instrumentation Service 39