CLI Guide
• Power Consumption Status
• Probe Name
• Reading
• Warning Threshold
• Failure Threshold
• Amperage: Location and Reading
• Power Tracking Statistics
• Energy Consumption
• Measurement Start Time
• Measurement Finish Time
• Reading
• System Peak Power
• System Peak Amperage
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge
10G system onwards that support PMBus and that have hot-swappable power supplies and not systems that have a xed, non-
redundant power supply installed.
NOTE: Power monitoring requires license to report the details. If the appropriate license is not installed or has expired, the
system does not display the power consumption details of the system. For more information, see the
Dell License Manager
at
Guide dell.com/openmanagemanuals.
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels
has changed. So, you may have to change the user scripts as applicable.
An example output reporting power statistics in Watts is as follows:
Table 28. Power statistics in watts
Power Consumption Information
Power Consumption
Index : 1
Status : Ok
Probe Name : System Board Pwr Consumption
Reading : 539W
Warning Threshold : 994W
Failure Threshold : 1400 W
Amperage
PS1 Current 1 : 1.2 A
Power Headroom
System Instantaneous Headroom : 300 W
System Peak Headroom : 340 W
Power Tracking Statistics
Statistic : Energy consumption
Measurement Start Time : Thu May 28 11:03:20 2011
Measurement Finish Time : Fri May 28 11:05:46 2011
Reading : 5.9 KWH
Statistics : System Peak Power
omreport Viewing System Status Using The Instrumentation Service 37