Use the omreport chassis or omreport mainsystem commands to view details for the entire chassis or for a particular component. Type:
omreport chassis
or
omreport mainsystem
Server Administrator displays a general status for the main system chassis or main system components.
Table 11. General status
Health
Main System Chassis
SEVERITY : COMPONENT
Ok : Fans
Critical : Intrusion
Ok : Memory
Ok : Power Supplies
Ok : Temperatures
Ok : Voltages
Chassis management
On servers with Dell PowerEdge FX2 series chassis, when Chassis Management at Server Mode is set to Monitor or Manage and
Monitor in CMC, OMSA displays Chassis Management at Server Mode as Enabled and displays the Fans, Power Supplies, and
Temperature sensor details. The sensor details are read-only. When Chassis Management at Server Mode is set to None in CMC, OMSA
displays Chassis Management at Server Mode as Disabled and displays only the server temperature sensors (not chassis temperature
sensors).
Related Links
omreport chassis fans or omreport mainsystem fans
omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
omreport chassis temps or omreport mainsystem temps
Omreport chassis acswitch or omreport mainsystem acswitch
Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that are
congured in a failover arrangement. Type:
omreport chassis acswitch
or
omreport mainsystem acswitch
omreport Viewing System Status Using The Instrumentation Service