CLI Guide

Omcong Reset All Temperature Probe Thresholds
Table 204. Omcong Reset All Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default value for all
temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax
omconfig storage enclosure action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>, where id is the controller ID. The <ENCLOSUREID> variable species
the enclosure.
In this syntax, n is a user-specied alphanumeric string.
Example to Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1.
Example for SAS controllers
omconfig storage enclosure action= resetalltempprobes controller=1
enclosure=2:3
Omcong Blink
Table 205.
omcong Blink
Description Blinks the light-emitting diodes (LEDs) on the enclosure.
Syntax
omconfig storage enclosure action=blink controller=id
enclosure=<ENCLOSUREID>, where id is the controller ID. The <ENCLOSUREID> variable species
the enclosure.
Example to Blink the LEDs for enclosure 3 attached to connector 2 on controller 1.
Example for SAS controllers
omconfig storage enclosure action=blink controller=1 enclosure=2:3
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=blink controller=1 enclosure=2
Omcong Battery Commands
The following table displays the omcong command syntax required to execute battery tasks.
Table 206.
Omcong Battery Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs
omcong storage battery action=startlearn controller=id battery=id
action=delaylearn controller=id battery=id days=d hours=h
Omcong storage commands 189