CLI Guide

Omcong Reset Temperature Probe Thresholds
Table 202. omcong Reset Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default values.
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage enclosure action=resettempprobes controller=id
enclosure=<ENCLOSUREID> index=id, where id is the controller ID and the temperature probe
ID. The <ENCLOSUREID> variable species the enclosure.
In this syntax, n is a user-specied alphanumeric string.
Example to Reset the thresholds for temperature probe 3, residing in the enclosure attached to connector 2 on
controller 1, to the default values.
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=resettempprobes controller=1
enclosure=2 index=3
NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on
controller 1.
Omcong Set All Temperature Probe Thresholds
Table 203.
Omcong Set All Temperature Probe Thresholds
Description Sets the minimum and maximum warning temperature thresholds for all temperature probes in the
enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax
omconfig storage enclosure action=setalltempprobes controller=id
enclosure=<ENCLOSUREID> minwarn=n maxwarn=n, where id is the controller ID. The
<ENCLOSUREID> variable species the enclosure.
In this syntax, n is a user-specied alphanumeric string.
Example to Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on controller
1, to 10 and 40 degree Celsius.
Example for SAS controllers
omconfig storage enclosure action=setalltempprobes controller=1
enclosure=2:3 minwarn=10 maxwarn=40
188 Omcong storage commands