CLI Guide
autoreplacememberonpredictivefailure= <enabled
| disabled> persistenthotspare=<enabled |
disabled> nrdiskcachepolicy=<enabled | disabled
|unchanged>
Example to
Example
Enable revertible hot spare and replace member operation.
omconfig storage controller action=
setchangecontrollerproperties
allowrevertiblehotspare
andreplacemember=enabled controller=1
Example to
Example
Allows to enable, disable, or not to change the Non-RAID Hard Disk
Drives. This is applicable only to Disk Cache Policy.
omconfig storage controller action=
setchangecontrollerproperties controller=1
nrdiskcachepolicy=enabled
Omcong Discard Preserved Cache
Table 173. Omcong Discard Preserved Cache
Description Discards the preserved cache on the controller.
NOTE: To check if the controller has a preserved cache, type omreport storage controller
controller=id. If the system displays Preserved Cache=yes, it indicates the presence of the
preserved cache.
Syntax
omconfig storage controller action= discardpreservedcache controller=id
force=enabled | disabled
If you set force=enabled, the cache is discarded irrespective of whether the controller detects a foreign or an oine
virtual disk.
Example to Discard the preserved cache.
Example
omconfig storage controller action= discardpreservedcache controller=1 force=enabled
CAUTION: Discarding the preserved cache can result in data loss. It is recommended that you run this
command using the force=disabled option.
NOTE: If a foreign conguration is detected, then the preceding command using force=disabled option
fails. To avoid data loss, import the foreign conguration and ush the preserved cache to disk. To discard
preserved cache forcefully, either clear the foreign conguration and run the proceeding command, or run
the proceeding command using force=enabled option.