CLI Guide

NOTE: To convert multiple non-RAID to RAID on a given
controller, use omcong storage controller
action=convertnonraidtoraid command. For more
information, see omcong Convert Multiple Non-RAID To
RAID.
Example to Convert non-RAID to RAID on physical disk 3 on connector 0 of
controller 1. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SAS controllers
omconfig storage pdisk action=nonraidtoraid
controller=1 pdisk=0:2:3
Omcong Set array disk cache
Table 130. Omcong Set array disk cache
Description Setting the disk cache policy on the given physical disk.
Syntax
omconfig storage pdisk action=setarraydiskcache controller=id
pdisk=<PDISKID>, where PDISKID=<connector:enclosureID:portID | connector:targetID>.
Example to Set the disk cache policy on the physical disk.
Example
omconfig storage pdisk action=setarraydiskcache controller=0 pdisk=0:2:3
Omcong virtual disk commands
The following table provides the omcong command syntax required to run virtual disk tasks.
CAUTION
: The
omcong storage vdisk action=deletevdisk controller=id vdisk=id
command deletes a virtual disk. Deleting a
virtual disk destroys all information including le systems and volumes residing on the virtual disk.
Table 131. Omcong Manage Virtual Disk Commands
Required Command Levels (1,
2, 3)
Optional name=value pairs
omcong storage vdisk action=checkconsistency controller=id vdisk=id
action=cancelcheckconsistency controller=id vdisk=id
action=pausecheckconsistency controller=id vdisk=id
action=resumecheckconsistency controller=id vdisk=id
action=checkconsistency controller=id vdisk=id
action=blink controller=id vdisk=id
action=unblink controller=id vdisk=id
action=initialize controller=id vdisk=id
action=fastinit controller=id vdisk=id [force=yes]
action=slowinit controller=id vdisk=id [force=yes]
156 Omcong storage commands