CLI Guide

Omcong Rebuild Physical Disk
Table 120. omcong Rebuild Physical Disk
Description Rebuilds a failed physical disk. Rebuilding a disk may take several
hours. If you need to cancel the rebuild, use the Cancel Rebuild
task. For more information about Rebuild Physical Disk, see the Dell
EMC OpenManage Online Help.
Syntax
omconfig storage pdisk action=rebuild
controller=id pdisk=<PDISKID>, where id is the controller
ID. The <PDISKID> variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Rebuild physical disk 3 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=rebuild
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=rebuild
controller=1 pdisk=0:2:3
Omcong Cancel Rebuild Physical Disk
Table 121.
omcong Cancel Rebuild Physical Disk
Description
Cancels a rebuild that is in progress. If you cancel a rebuild, the
virtual disk remains in a degraded state. For more information about
Cancel Rebuild Physical Disk, see the Dell EMC OpenManage
Online Help.
Syntax
omconfig storage pdisk action=cancelrebuild
controller=id pdisk=<PDISKID>, where id is the controller
ID. The <PDISKID> variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Cancel the rebuild of physical disk 3 on connector 0 of controller 1.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=cancelrebuild
controller=1 pdisk=0:3
Omcong storage commands 151