CLI Guide

The following table displays the valid parameters for the command.
Table 75. Valid Parameters Of System Shutdown
name=value pair Description
action=reboot Shuts down the operating system and initiates system startup, performing BIOS checks and reloading the
operating system.
action=powero Turns o the electrical power to the system.
action=powercycle Turns o the electrical power to the system, pauses, turns on the power, and reboots the system. Power
cycling is useful when you want to reinitialize system components such as hard drives.
osrst=true | false
true: Closes the le system and exits the operating system before turning o the server.
false: Does not close the le system or shuts down the operating system before turning o the server.
NOTE: This command osrst=false is not available on 13G and later systems. By default, on 13G and
later systems, the operating system shuts down before turning o the server during a remote
shutdown.
Example Shutdown Commands
To set the shutdown action to reboot, type:
omconfig system shutdown action=reboot
or
omconfig servermodule shutdown action=reboot
To bypass operating system shutdown before the system is powered o, type:
omconfig system shutdown action=reboot osfirst=false
or
omconfig servermodule shutdown action=reboot osfirst=false
NOTE
: The parameter osrst=false is not available on 13G and later systems. By default, on 13G and later systems, the operating
system shuts down before turning o the server during a remote shutdown.
Omcong System Thrmshutdown Or Omcong Servermodule
Thrmshutdown
Use the omcong system thrmshutdown or omcong servermodule thrmshutdown command to congure a thermal shutdown action. You
can congure the system for a thermal shutdown when a temperature probe detects a temperature probe warning or failure event.
The following table displays the valid parameters for the command:
Table 76. Valid Parameters Of Thermal Shutdown
name=value pair Description
severity=disabled | warning | failure
disabled: Disable thermal shutdown. An administrator must intervene.
120 Omcong Managing Components Using The Instrumentation Service