CLI Guide
Event Name Description
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card warning is
displayed.
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not
available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual SD
card is lost.
event=watchdogasr Enables or disables alert generation congured by the ASR when the system has hung or is
not responding.
Omcong system snmptraptest or omcong servermodule
snmptraptest
Use the omcong system snmptraptest or omcong servermodule snmptraptest command to send the snmp test trap to the destination
address if Server Administrator SNMP component is congured in the conguration le.
The following table displays the valid parameters for the command:
Table 70. Parameters For Alert Action Command
Action Description
dest=<ipv4 address | ipv6
address | fqdn>
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMware ESXi.
Omcong System Events Or Omcong Servermodule Events
Use the omcong system events or omcong servermodule events command to enable and disable SNMP traps for the components on
your system.
NOTE
: Not all event types are present on the system.
There are four parameters in the name=value pair component of the omcong system events command:
• Source
• Type
• Severity
• Index
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event notication for
the system’s components.
omconfig system events source=snmptraps
116
Omcong Managing Components Using The Instrumentation Service