CLI Guide

Omcong system platformevents or omcong servermodule
platformevents
Use the omcong system platformevents or omcong servermodule platformevents command to congure shutdown action, if any, taken
for a specic platform event. You can also enable or disable platform event lter alert generation.
CAUTION: If you set a platform event shutdown action to anything other than
none
or
power reduction
, the system is forcefully
shut down when the specied event occurs. This shutdown is initiated by rmware and is carried out without rst shutting down
the operating system or any of the applications running on your system.
The following table displays the valid parameters for the command.
NOTE: Alert settings are mutually exclusive and you can set one at a time only. The action settings are also mutually exclusive
and you can set one at a time only. However, alert and action settings are not mutually exclusive of each other.
Table 68. Parameters For Alert Action Command
Action Description
action=disable Disables the SNMP alert.
action=enable Enables the SNMP alert.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns o the electrical power to the system, pauses, turns on the power, and reboots the system.
action=powero Turns o the electrical power to the system.
action=powerreduction Reduces the processor speed until the power consumption comes down and reaches below the warning
threshold. If the system power consumption remains below the warning threshold, increase the processor
speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems earlier than 11th
generation of PowerEdge systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs BIOS checks, and reloads
the operating system.
Components and events of platform events
The following table lists the components and the events for which you can set platform events. Components are listed in alphabetical order,
except that warning events always precede failure events for a component.
Table 69. Valid Parameters Of
Omcong System Platformevents
Event Name Description
alertsenable=true | false
true: Enables generation of platform event lter alerts.
false: Disables generation of platform event lter alerts.
NOTE: This setting is independent of the individual platform event lter alert
settings. For a platform event lter to generate an alert, both the individual alert
and the global event alert are enabled.
event=batterywarn Sets action or enables or disables alert generation when a battery device detects that the
battery is pending a failure condition.
114 Omcong Managing Components Using The Instrumentation Service