Release Notes

The Environment Variables pop-up screen is displayed.
4. Click OK and exit from the screen.
Issue description: Configure HTTPS Listener link page does not time out. (498330). If you click the Configure HTTPS listener link in the
Prerequisite page, the page does not time out.
Resolution: To resolve this issue, close and reopen the page.
Issue description: Browser secure site warning message. (134991). When launching the Server Administrator Installation Guide from the
Prerequisite checker, a Windows message is displayed indicating that the page is blocked due to enhanced security configuration.
Resolution: Add this site to the Trusted Sites list, or minimize the security settings. Versions Affected: 8.3.0 and earlier.
Issue description: MSI reference counts affected for Intel SNMP agent install. MSI reference counting takes effect if you install the Intel
SNMP agent using the Intel MSI. Installs the Intel SNMP agent again using the Server Administrator installer.
Resolution: The Intel SNMP agent is not uninstalled during installation of the MSI; Remove both installers from the system to remove the
agent.
Issue description: After applying OM 8.4 DUP, reboot message is displayed (195399)
Resolution: When upgrading to OMSA 8.3, ensure that inventory collector (invcol.exe) is not running. If you still upgrade to OMSA 8.3
when inventory collector is running, then the installer may prompt you to restart the system. However, restarting the system is not
mandatory as Server Administrator continues to work as expected without any functional limitation.
Issue description: Insufficient Privilege error message while uninstallation (241136) (241498)
Error message appears when an Active Directory user, member of Domain Admins , and Domain Users group uninstall Server
Administrator.
Resolution: To fix this issue, the user can open the command prompt as Administrator and run the command: msiexec /x
<msiname>.msi
Issue description: On a 13th generation of PowerEdge server if you run the Server Administrator 8.4 installer, the incorrect Software
RAID controller driver is being installed. (241203)
Resolution: To fix this issue, you can visit http://downloads.dell.com/ and install the correct Software RAID driver for your server.
Known Issues on Linux operating systems
Issue description: Server Administrator components get removed during an OS upgrade. (380137). During an OS upgrade, some of the
srvadmin packages may get removed.
Resolution: After an operating system upgrade, reinstall the Server Administrator since the srvadmin packages may not be applicable for
the upgraded operating system.
Example: After upgrading SLES 10 to SLES 11, Server Administrator must be reinstalled as the SLES 10
srvadmin packages may not work with SLES 11.
Versions Affected: 8.4.0 and earlier
Issue description: Existing connection service lost after SLES 11 upgrade. (388955). Server Administrator version 6.x for Linux does not
have a functional Connection Service web GUI after upgrading SUSE Linux Enterprise Server 11 using Service Pack 1. Also, the installed
WS-MAN service for OMSA does not function.
Resolution: To prevent it:
1. Before upgrading SLES 11 operating system, manually uninstall the open-source packages like OpenWSMAN, SFCB, SFCC and
LibCmpiCppImpl packages with
— nodeps option.
2. Upgrade the SLES11 operating system using Service Pack 1.
If the system is upgraded and is facing issues, then, reinstall the following Server Administrator packages from the install media:
rpm -Uhv srvadmin-iws-*.sles11.rpm --nodeps rpm -Uhv srvadmin-itunnelprocider-*.sles11.rpm –
nodeps
Versions Affected: 8.4.0 to 6.0
Issue description: On a system running supported Linux operating system (French), the System Administrator Shortcut is not available.
(124261)
Resolution: To connect to the local Server Administrator Web Server, open a web browser and then connect to the URL https://
localhost:1311 to access Server Administrator. (124261)
Dell EMC OpenManage Installation and Management Release Notes Version 9.0.2
3