Users Guide
• Power Reduction
Throttles the CPU.
CAUTION: If you select a Platform Event shutdown action other than None or Power Reduction, your system
shuts down forcefully when the specied event occurs. This shutdown is initiated by rmware and is done
without rst shutting down the operating system or any running applications.
NOTE: Power reduction is not supported on all systems. Power Supply Monitoring and Power Monitoring
features are available only for systems that have two or more redundant, hot-swappable power supplies installed.
These features are unavailable for permanently installed, non-redundant power supplies that lack power
management circuitry.
6. Select the Generate Alert check box for the alerts to be sent.
NOTE: To generate an alert, you must select both Generate Alert and the Enable Platform Events Alerts settings.
7. Click Apply.
8. Click Apply to Platform Events Page to go back to the Platform Event Filters window.
プラットフォームイベントアラート送信先の設定
プラットフォームイベントフィルタのウィンドウを使用して、プラットフォームイベント用のアラートが送信される宛先を選択します。お使いのシステムに
表示される送信先の数に応じて、各送信先アドレスに個別の IP アドレスを設定することができます。プラットフォームイベントアラートは、ユーザー
が設定する送信先 IP アドレスそれぞれに送信されます。
1. プラットフォームイベントフィルタのウィンドウで、宛先の設定 をクリックします。
2. 設定する宛先の番号をクリックします。
メモ: 特定のシステムで設定できる送信先の数は、異なる場合があります。
3. トラップ先を有効にする チェックボックスを選択します。
4. 宛先番号 をクリックして、その宛先の個々の IP アドレスを入力します。この IP アドレスは、プラットフォームイベントのアラートが送信される IP
アドレスです。
メモ: iDRAC7 固有のバージョンがある第 12 世代システムでは、プラットフォームイベント宛先を IPv4、IPv6、または FQDN とし
て設定することができます。
5. 管理ステーションと管理下システム間で送信されるメッセージの認証に使用するパスワードとして機能する値を コミュニティ文字列 フィールド
に入力します。コミュニティ文字列
(コミュニティ名とも呼ばれます)は、管理ステーションと管理下システム間におけるパケットごとに送信され
ます。
6. 適用 をクリックします。
7. プラットフォームイベントページに戻る をクリックすると、プラットフォームイベントフィルタ ウィンドウに戻ります。
54