Users Guide
• 在确认新密码字段中重新键入新密码。
5. 指定以下用户权限:
• 选择最大 LAN 用户权限级别限制。
• 选择准予的最大串行端口用户权限。
6. 为 DRAC/iDRAC 用户权限指定用户组。
7. 单击应用更改以保存更改。
8. 单击返回至远程访问用户窗口以返回至远程访问用户窗口。
注: 当安装了 DRAC 时,有六个附加的用户项可配置。这造成共 16 个用户。BMC/iDRAC 和 RAC 用户使用相同的用
户名和密码规则。当安装了
DRAC/iDRAC6 时,所有 16 个用户项都分配给 DRAC。
Setting Platform Event Filter Alerts
To congure the most relevant BMC features, such as Platform Event Filter (PEF) parameters and alert destinations using Server
Administrator Instrumentation Service:
1. Click the System object.
2. Click the Alert Management tab.
3. Click Platform Events.
The Platform Events window allows you to take individual action on specic platform events. You can select those events for
which you want to take shutdown actions and generate alerts for selected actions. You can also send alerts to specic IP
address destinations of your choice.
NOTE: You must be logged in with Administrator privileges to congure the BMC PEF Alerts.
NOTE: The Enable Platform Event Filters Alerts setting disables or enables PEF alert generation. It is independent of
the individual platform event alert settings.
NOTE: System Power Probe Warning and System Power Probe Failure are not supported on the PowerEdge
systems without PMBus support although Server Administrator allows you to congure them.
4. Choose the platform event for which you want to take shutdown actions or generate alerts for selected actions and click Set
Platform Events.
The Set Platform Events window allows you to specify the actions to be taken if the system is to be shut down in response to
a platform event.
5. Select one of the following actions:
• None
• Reboot System
Shuts down the operating system and initiates system startup, performing BIOS checks and reloading the operating system.
• Power O System
Turns o the electrical power to the system.
• Power Cycle System
Turns the electrical power to the system o, pauses, turns the power on, and reboots the system. Power cycling is useful
when you want to reinitialize system components such as hard drives.
• Power Reduction
Throttles the CPU.
CAUTION: If you select a Platform Event shutdown action other than None or Power Reduction, your system
shuts down forcefully when the specied event occurs. This shutdown is initiated by rmware and is done
without rst shutting down the operating system or any running applications.
NOTE: Power reduction is not supported on all systems. Power Supply Monitoring and Power Monitoring
features are available only for systems that have two or more redundant, hot-swappable power supplies installed.
These features are unavailable for permanently installed, non-redundant power supplies that lack power
management circuitry.
50