Release Notes

resolve this issue, you must restart the server after using the Auto Congure RAID0 operation to ensure that all the physical
disks in Ready state are created with RAID 0 volumes.
BITS268181: When a user creates a virtual disk using the GUI, physical disks are not listed under Dedicated Hot spare (DHS). So,
the user will not be able to assign DHS while creating a virtual disk.
Workaround: After creating the virtual disk, the user can assign DHS using the Assign/Unassign Dedicated Hot spare virtual disk
operation.
JIT-16919 (BITS270856): On Precision 7910 running a client operating system (for example, Windows 8.1 x64), the PERC 9.3
driver version is displayed as outdated and a yellow bang is shown on such hardware congurations. This issue does not cause
any functionality limitation.
BITS271311: If you create RAID 50 or 60 conguration with 22 or 26 physical disks using the CLI, the operation is unsuccessful.
This issue is observed on all the operating systems and is limited to only RAID 50 or 60 conguration with 22 or 26 physical disks.
Workaround: To resolve this issue, you can create RAID 50 or 60 conguration using the OMSS GUI.
JIT-16740: OMSS storage connector information for HBA330 Adaptor is incorrect. If connector A and B is connected to a
corresponding backplane SAS-A & B port, OMSS is displaying all the physical disks under Connector-1 and none under
Connector-0. This issue does not cause any functionality limitation.
JIT-4248: Inconsistent behavior while enumerating physical disks connected to MD3060e enclosure. MD3060e enclosure is
unsupported by OMSS hence no need to show any drives exposed via 12 Gbps HBA.
JIT-31342: Virtual disk creation on Software RAID S130 controller with multiple Dedicated Hot Spare (DHS) assigned displays an
error message. Assigning DHS is unsuccessful only when the user selects more than one DHS during virtual disk creation. There
are no other issues observed during virtual disk creation.
Workaround: After the virtual disk is created, you can assign multiple DHS to the virtual disk by selecting the Assign Dedicated
Hot Spare task from the Available Tasks drop-down menu of the virtual disk.
JIT-43557: In Split Mode, Slot occupancy report displays inaccurate empty slots when there are no drives connected to the
backplane. The report shows the message empty slots interchanged between controller.
This issue occurs for the server with no drives attached to the backplane in split mode only. Slot occupancy report works ne as
expected for servers with a minimum of one drive.
JIT-50416: OMSS freezes if LVM group name starts with nvme. This issue is occurs only on Linux platforms.
Workaround: Rename the LVM group with the command: vgrename /dev/nvme//dev/
anything_that_does_not_start_with_the_letters_NVME!.
JIT-55404: The LED blink and unblink operations are not working with SATA SSDs on C6420.
JIT-54541: OMSS is not displaying the physical disks which is connected to HBA330(Adapter and Mini) controller on C6400 and
C6420.
JIT-47971: After deleting one of the virtual disks, few of the virtual disk tasks are missing from the available virtual disk.
Work Around: If we execute any of the virtual disk tasks in available virtual disk, the missing tasks will be displayed.
JIT-49823: When BIOS NVMe setting is in non-RAID mode, OMSS displays the NVMe drives connected to S140 controller.
Installation Prerequisites
Storage Management does not display controllers and their features on systems that do not meet the driver and rmware
requirements. At Storage Management runtime, you can determine whether the system meets the rmware requirement or not, by
checking the application log les for notications on outdated rmware. At runtime, On SCSI controllers, Storage Management
displays the rmware version at runtime while on SAS controllers it displays the rmware and driver versions.
Installation Procedure
For complete installation instructions, see the Server Administrator version 8.5 Installation Guide.