Connectivity Guide
Syntax DisplayString
Table 1838. Service Tag
Variable Name
alertServiceTag
Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9
Description Species the system service tag of the system generating the alert.
Syntax DisplayString
Table 1839. Chassis Service Tag
Variable Name
alertChassisServiceTag
Object ID 1.3.6.1.4.1.674.10892.4.5000.10.10
Description Species the chassis service tag of the system generating the alert.
Syntax DisplayString
Understanding The Trap Description
The following table lists in alphabetical order each line item that may appear in the trap description.
Table 1840. Trap Description
Description Line Item Explanation
Action performed was:
<Action>
Species the automatic server recovery action that was performed, for example:
Action performed was: Power cycle
Action requested was:
<Action>
Species the user initiated host control action that was requested, for example:
Action requested was: Reboot, shutdown OS first
Additional details:
<Additional details for
the events>
Species possible additional details about the specied device, for example:
Additional details:
Memory device: DIMM_1A Serial number: 11111111
Memory device: DIMM_1B Serial number: 22222222
<Additional power supply
status information>
Species any additional power supply information pertaining to the event, for example:
Power supply input AC is off, Power supply POK (power OK)
signal is not normal, Power supply is turned off
Battery sensor status:
<status>
Species the status reported by the battery sensor, for example:
Battery sensor status: Predictive failure
Chassis intrusion state:
<Intrusion state>
Species the chassis intrusion state (open or closed), for example:
Chassis intrusion state: Open
Chassis location: <Name of
chassis>
Species the name of the chassis that generated the message, for example:
Chassis location: Main System Chassis
Configuration error type:
<type of configuration
error>
Species the type of conguration error that occurred, for example:
Configuration error type: Revision mismatch
Current sensor value (in
Amps): <Reading>
Species the current sensor value in amps, for example:
Current sensor value: 7.853
Date and time of action:
<Date and time>
Species the date and time that an automatic server recovery action was performed, for
example:
417