Connectivity Guide
Syntax DellStatusRedundancy
Access Read-only
Table 68. System State AC Power Switch Status Details
Name
systemStateACPowerSwitchStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.34
Description Denes the individual status of all AC power switches in this chassis. The rst byte
returned represents the status of the rst AC power switch, the second byte returned
represents the status of the second AC power switch, and so on.
Syntax Octet String
Access Read-only
Table 69. System State AC Power Cord State Details
Name
systemStateACPowerCordStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35
Description Denes the individual state of all AC power cords for any AC power switches in this
chassis. The rst byte returned represents the state of the rst AC power cord, the second
byte returned represents the state of the second AC power cord, and so on.
Syntax Octet String
Access Read-only
Table 70. System State AC Power Cord Status Combined
Name
systemStateACPowerCordStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.36
Description Denes the overall status of all AC power cords for any AC power switches in this chassis.
Syntax DellStatus
Access Read-only
Table 71. System State AC Power Cord Status Details
Name
systemStateACPowerCordStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37
Description Denes the individual status of all AC power cords for any AC power switches in this
chassis. The rst byte returned represents the status of the rst AC power cord, the
second byte returned represents the status of the second AC power cord, and so on.
Syntax Octet String
Access Read-only
Table 72. System State Redundant Memory Unit State Details
Name
systemStateRedundantMemoryUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38
30