Dell EMC OpenManage SNMP Reference Guide Version 9.0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction..................................................................................................................... 7 Supported SNMP Versions................................................................................................................................................. 7 Managed Object Used in This Document............................................................................................................................
Thermal Group Tables................................................................................................................................................ 116 Thermal Group Variable Values..................................................................................................................................125 Remote Flash BIOS Group..............................................................................................................................................
Array Disk Channel Connection Table........................................................................................................................361 Fan Table..................................................................................................................................................................363 Fan Connection Table...............................................................................................................................................
Common Data Types...................................................................................................................................................... 428 Variables with Data Types of State Capabilities and State Capabilities Unique................................................................428 Dell Status Data Types................................................................................................................................................... 429 Dell Date............
1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell EMC OpenManage. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to SNMP Reference Guide, explains the SNMP Reference Guide design.
MIB Name Agent / Hardware Supported Purpose of the MIB dcs3rmt.mib Dell Remote Access controller 5 (DRAC 5) Provides information about remote access components monitored by the Server Administrator Remote Access Service. rac_host.mib Remote access out-of-band agent Provides information about the components monitored by the remote access out-of-band software agent. DELL-RAC-MIB.
Section Topics MIB Group Numbers 9 Thermal Group — defines variables for temperature probes and cooling devices 700 10 User Security Group — defines variables for creating and modifying user accounts 800 11 Remote Flash BIOS Group — defines variables for updating the system’s BIOS remotely 900 12 Port Group — defines variables for major port types such as keyboard, monitor, small computer system interface (SCSI), Universal Serial Bus (USB), and parallel and serial ports 1000 13 Device Group
Table 4.
Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at dell.com/support/manuals.
Table 8. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 9. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 10. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables.
For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms. Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard.
ENTERPRISES(1 ) DELL (674) SNMPv2(6) In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
2 Server Administrator Group The Server Administrator group comprises of the following sections: • Instrumentation MIB Version Group • Systems Management Software Group • System State Group • Chassis Information Group • Operating System Group • System Resource Group • Power Group • Thermal Group • Remote Flash BIOS Group • Port Group • Device Group • Slot Group • Memory Group • BIOS Setup Control Group • Local Response Agent Group • Cost of Ownership Group • Cluster Group •
Access Read-only Management Information Base Minor Version Number Table 15. Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes.
Table 17. Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name. Syntax DellString Access Read-only Table 18. Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1.3.6.1.4.1.674.10892.1.100.2 Description Defines the version number of the systems management software. Syntax DellString Access Read-only Table 19.
Access Read-only Table 23. Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelName Object ID 1.3.6.1.4.1.674.10892.1.100.7 Description Defines the update level of the system management software. Syntax DellString Access Read-only Table 24. Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software.
Syntax SMSSNMPAgentFeatureFlags (Systems Management Software SNMP Agent Feature Flags) Access Read-only Table 29. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software.
System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table.
• systemStateCoolingDeviceStatusDetails • systemStateTemperatureStatusDetails • systemStateMemoryDeviceStatusDetails • systemStateChassisIntrusionStatusDetails • systemStateACPowerCordStatusDetails • systemStatePowerUnitStatusList • systemStateCoolingUnitStatusList • systemStateACPowerSwitchStatusList • systemStateRedundantMemoryUnitStatusList • systemStateProcessorDeviceStatusList • systemStateBatteryStatusList • systemStateSDCardUnitStatusList • systemStateSDCardDeviceStatusList
Description Defines the global system status of all chassis being monitored by this instrumentation instance. Syntax DellStatus Access Read-only Table 37. System State Chassis State Name systemStateChassisState Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.3 Description Defines the system state of this chassis. Syntax DellStateSettings Access Read-only Table 38. System State Chassis Status Name systemStateChassisStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Description Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific power unit. The first byte returned represents the status of the first power unit, the second byte returned represents the status of the second power unit, and so on. The bytes have the same definition type as DellStatusRedundancy. Syntax Octet String Access Read-only Table 42.
returned represents the status of the second voltage probe, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String Access Read-only Table 46. System State Voltage Status Combined Name systemStateVoltageStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.12 Description Defines the status of all voltage probes in this chassis. Syntax DellStatus Access Read-only Table 47.
Description Defines the status of all amperage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific amperage probe. The first byte returned represents the status of the first amperage probe, the second byte returned represents the status of the second amperage probe, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 51.
returned represents the state of the second cooling device, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String Access Read-only Table 55. System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21 Description This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined status value.
Access Read-only Table 59. System State Temperature Status Details Name systemStateTemperatureStatusDetailsly Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25 Description Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. Syntax Octet String Access Read-only Table 60.
Table 63. System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
Syntax DellStatusRedundancy Access Read-only Table 68. System State AC Power Switch Status Details Name systemStateACPowerSwitchStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.34 Description Defines the individual status of all AC power switches in this chassis. The first byte returned represents the status of the first AC power switch, the second byte returned represents the status of the second AC power switch, and so on. Syntax Octet String Access Read-only Table 69.
Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String Access Read-only Table 73.
Description Lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 78. System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 82. System State Redundant Memory Unit Status Combined Name systemStateRedundantMemoryUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48 Description Defines the combined status of all redundant memory units of this chassis. Syntax DellStatus Access Read-only Table 83. System State Redundant Memory Unit Status List Name systemStateRedundantMemoryUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 87. System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 88.
Syntax Octet String Access Read-only Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
Access Read-only Table 95. Chassis State Capabilities Name chassisStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.2 Description Defines the capabilities of the chassis. Syntax DellStateCapabilities Access Read-only Table 96. Chassis State Settings Name chassisStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.3 Description Defines the state settings for the chassis. Syntax DellStateSettings Access Read-only Table 97.
Syntax DellString Access Read-only Table 101. Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Table 102. Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Table 103.
Syntax DellUnsigned16BitRange Access Read-only Table 107. Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.14 Description Defines the chassis class of this chassis. Syntax DellChassisSystemClass (See Chassis Type) Access Read-only Table 108. Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Table 109.
Syntax DellString Access Read-only Table 113. Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-only Table 114. Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Syntax DellLEDControlSettings (See Front-Panel LED Control Settings) Access Read-only Table 119. Chassis Hard-Drive (HD) Fault Clear Control Capabilities Name chassisHDFaultClearControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.26 Description Specifies whether the chassis allows reset of the chassis hard-drive fault LED. Syntax DellHDFaultLEDControlCapabilities (See Hard-Drive Fault LED Control Capabilities ) Access Read-only Table 120.
Syntax DellHostControlCapabilities (See Host Control Capabilities) Access Read-only Table 125. Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Host Control Settings) Access Read-only Table 126. Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.
Description Specifies whether Simple Network Management Protocol (SNMP) Set type commands are allowed by Server Administrator. This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP master agent. Syntax DellBoolean Access Read-only Table 131. Chassis Power Button Control Capabilities Unique Name chassisPowerButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.38 Description Defines the capabilities of the power button control function.
Table 136. Chassis Reseller System ID Name chassisResellerSystemID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43 Description Defines the chassis reseller system ID. Syntax DellUnsigned16BitRange Access Read-only Table 137. Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function.
Access Read-only Table 142. Chassis Express Service Code Name Name chassisExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.49 Description Defines the express service code of the chassis. Syntax DellString Access Read-only Table 143. Chassis Node ID Name chassisNodeIDName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.50 Description Defines the NodeID of the chassis.
Access Read-only Table 147. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 148. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 149. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Access Not accessible Index postLogchassisIndex , postLogRecordIndex Table 152. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 153. POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log.
Access Read-only Table 157. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format) Access Read-only Event Log Table Table 158. Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40 Description Defines the Event Log Table. Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Table 159.
Access Read-only Table 162. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Table 163. Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4 Description Defines the state settings for the object that is writing the event log.
Table 167. Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Table 168. System BIOS Table Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table.
Access Read-only Table 172. System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object. Syntax DellStateCapabilities Access Read-only Table 173. System BIOS State Settings Name systemBIOSStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4 Description Defines the state of the system BIOS of this object. Syntax DellStateSettings Access Read-only Table 174.
Table 177. System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8 Description Defines the version name of the system BIOS. Syntax DellString Access Read-only Table 178. System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9 Description Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only Table 179.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Syntax Bit 3 - BIOS Characteristics Not Supported Bit 4 - ISA is supported Bit 5 - MCA is supported Bit 6 - EISA is supported Bit 7 - PCI is supported Bit 8 - PC Card (PCMCIA) is supported Bit 9 - Plug and Play is supported Bit 10 - APM is supported Bit 11 - BIOS is Upgradeable (Flash) Bit 12 - BIOS shadowing is allowed Bit 13 - VL-VESA is supported Bit 14 - ESCD support is available Bit 15 - Boot from CD is supported Bit 16 - Selectab
• • • • Bit 4 - LS-120 boot is supported Bit 5 - ATAPI ZIP Drive boot is supported Bit 6 - 1394 boot is supported Bit 7 - Smart Battery supported Syntax DellUnsigned8BitRange Access Read-only Table 183. System BIOS Characteristics Ext 2 Name systemBIOSCharacteristicsExt2 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14 Description Defines additional characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Syntax DellObjectRange Access Read-only Table 187. Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2 Description Defines the index (one-based) of the firmware in this chassis. Syntax DellObjectRange Access Read-only Table 188. Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Table 189.
Syntax DellFirmwareType Access Read-only Table 193. Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Table 194. Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9 Description Defines the bitmap of supported methods for firmware update. Syntax DellUnsigned16BitRange Access Read-only Table 195.
Table 198. Intrusion Table Entry Name intrusionTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.70.1 Description Defines the Intrusion Table entry. Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex , intrusionIndex Table 199. Intrusion Chassis Index Name intrusionchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 200.
Syntax DellStatus Access Read-only Table 204. Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Table 205. Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Table 206.
, baseBoardIndex Table 209. Baseboard Chassis Index Name baseBoardchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 210. Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board. Syntax DellObjectRange Access Read-only Table 211.
Syntax DellBaseBoardFeatureFlags Access Read-only Table 215. Baseboard Type Name baseBoardType Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7 Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Table 216. Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Table 217.
Syntax DellString Access Read-only Table 221. Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Table 222. Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14 Description Defines the baseboard PPID. Syntax DellString Access Read-only Table 223.
Table 226. Chassis Type Variable Name : DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis type is not one of the following: unknown(2) The chassis type is unknown. desktop(3) The chassis type is a desktop. lowProfileDesktop(4 The chassis type is a low-profile desktop. ) pizzaBox(5) The chassis type is a pizza box. miniTower(6) The chassis type is a minitower. tower(7) The chassis type is a tower. portable(8) The chassis type is a portable.
failure(4) The status of the chassis connection is failure. Table 228. Fan Control Capabilities Variable Name : DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable(2) The fan can be set to low speed. highSpeedCapable(4) The fan can be set to high speed. lowOrhighSpeedCapab The fan can be set to low or high speed. le(6) Table 229.
Table 232. Hard-Drive Fault LED Control Settings Variable Name : DellHDFaultLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any fault settings capabilities. unknown(1) The hard-drive fault LEDs’ state is unknown. enabled(2) The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The hard-drive fault LEDs’ state is not ready.
identifyChassisAndE The chassis identification control’s LEDs may be returned nable (10) to normal (a binary 0 value), or identify chassis and enabled (a binary 1 value). Table 235. Host Control Capabilities Variable Name : DellHostControlCapabilities NOTE: An operator can manually enable these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualRebootCapabl e(1) The operator can reboot capable host. manualPowerOFFCapab The operator can power off capable host.
Possible Data Values Meaning of Data Value manualReboot(1) The operator can reboot the host. manualPowerOFF(2) The operator can power off the host. manualPowerCycle(4) Power cycle the host. manualOperatingSyst The operator can shut down the operating system on the emShutdown(8) host. manualOperatingSyst The operator can shut down the operating system on the emShutdownThe host then power cycle machine. nPowerCycle(12) Table 237.
automaticPowerOffEn Automatic power off is enabled for this host. abled(8) Table 239. Watchdog Timer Capabilities Variable Name : DellWatchDogTimerCapabilities Data Type: Integer Possible Data Values Meaning of Data Value type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 240.
Data Type: Integer Possible Data Values Meaning of Data Value none(0) No properties. energySmart(1) The system is an Energy Smart System. Table 244. NMI Button Control Settings Variable Name : DellNMIButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no settings capabilities. unknown(1) The NMI button settings are unknown. enabled(2) The NMI button state is enabled. disabled(4) The NMI button state is disabled. Table 245.
workstationClass(3) The chassis system class is a workstation. serverClass(4) The chassis system class is a server. desktopClass(5) The chassis system class is a desktop. portableClass(6) The chassis system class is a portable. netPCClass(7) The chassis system class is a Net PC. storageClass(8) The chassis system class is storage. Table 247.
iDRAC8(22) The firmware type is Integrated Dell Remote Access Controller 8. Table 248. Baseboard Feature Flags Variable Name : DellBaseBoardFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value NOTE: These values are bit fields, so combination values are possible. no features(0) This baseboard has no feature flags. boardIsHostingBoar d(1) This baseboard is a hosting board. boardRequiresDaught This baseboard requires at least one daughter board or erBoard (2) auxiliary card.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 252. Operating System Memory State Capabilities Name operatingSystemMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.2 Description Defines the capabilities of the operating system memory. Syntax DellStateCapabilities Access Read-only Table 253. Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
Table 257. Operating System Memory Total Page File Size Name operatingSystemMemoryTotalPageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.7 Description Defines the total page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 258. Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes.
System Resource Group Tables The following MIB tables define objects for the System Resource Group: • System Resource Map Table • System Resource Owner Table • System Resource Input/Output (I/O) Port Table • System Resource Memory Table • System Resource Interrupt Table • System Resource Direct Memory Access (DMA) Table System Resource Map Table Table 262. System Resource Map Table Name systemResourceMapTable Object ID 1.3.6.1.4.1.674.10892.1.500.
Table 266. System Resource Map State Capabilities Name systemResourceMapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.3 Description Defines the capabilities of this system map. Syntax DellStateCapabilities Access Read-only Table 267. System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4 Description Defines the state and allows the setting of this system map. Syntax DellStateSettings Access Read-only Table 268.
Access Not accessible Index systemResourceOwnerchassisIndex , systemResourceOwnerIndex Table 272. System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 273. System Resource Owner Index Name systemResourceOwnerIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
Table 277. System Resource Owner Interface Type Name systemResourceOwnerInterfaceType Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.6 Description Defines the interface type for this system resource owner. Syntax DellResourceOwnerInterfaceType (Resource Owner Interface Type) Access Read-only Table 278. System Resource Map Index Reference Name systemResourceMapIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
Index systemResourceIOPortchassisIndex , systemResourceIOPortIndex Table 283. System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 284. System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.
Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 289. System Resource I/O Port Share Disposition Name systemResourceIOPortShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7 Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 290.
, systemResourceMemoryIndex Table 294. System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 295. System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis.
Syntax DellObjectRange Access Read-only Table 300. System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 301. System Resource Memory Starting Address Name systemResourceMemoryStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
Description Defines the System Resource Interrupt Table entry. Syntax SystemResourceInterruptTableEntry Access Not accessible Index systemResourceInterruptchassisIndex , systemResourceInterruptIndex Table 306. System Resource Interrupt Chassis Index Name systemResourceInterruptchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Not accessible Table 307.
Table 311. System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 312. System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
Access Not accessible Table 317. System Resource DMA Table Entry Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60.1 Description Defines the System Resource DMA Table entry. Syntax SystemResourceDMATableEntry Access Not accessible Index systemResourceDMAchassisIndex , systemResourceDMAIndex Table 318. System Resource DMA Chassis Index Name systemResourceDMAchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.
Table 322. System Resource DMA Status Name systemResourceDMAStatus Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.5 Description Defines the status of this system resource DMA. Syntax DellStatus Access Read-only Table 323. System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 324.
System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 328. System Resource Map Type Variable Name: DellSystemResourceMapType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The system resource map type is not one of the following: unknown(2) The system resource map type is unknown (not known or not monitored). typeOne(3) The system resource map is type 1 (one). Table 329.
memoryIsWriteOnly(2) The resource memory is write-only. memoryIsPreFetchable(4) The resource memory is prefetchable. memoryIsCombinedWritable(8 ) The resource memory is read-write. memoryIsF24(16) The resource memory is F24. Table 332. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive( 1) The interrupt type is level sensitive. interruptIsLatched(2) The interrupt type is latched. Table 333.
dmaTransferWidthIs16Bits(4 ) The DMA transfer width is 16 bits. dmaTransferWidthIs32Bits(5 ) The DMA transfer width is 32 bits. dmaTransferWidthIs64Bits(6 ) The DMA transfer width is 64 bits. dmaTransferWidthIs128Bits( 7) The DMA transfer width is 128 bits. Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes.
Table 338. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 339. Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Table 340.
Access Read-only Table 344. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Table 345. Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8 Description Defines the status of the power unit in this chassis. Syntax DellStatus Access Read-only Power Supply Table Table 346.
Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 350. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique) Access Read-only Table 351. Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.
Description Defines the location name of the power supply. Syntax DellString Access Read-only Table 356. Power Supply Maximum Input Voltage Name powerSupplyMaximumInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9 Description This attribute defines the maximum input voltage of the power supply (in Volts). Syntax DellSigned32BitRange Access Read-only Table 357. Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.
Table 361. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Table 362. Power Supply FQDD Name powerSupplyFQDD Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.15 Description Fully qualified device descriptor (FQDD) of the power supply. Syntax FQDDString Access Read-only Table 363.
Access Read-only Table 367. Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Table 368. Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe. Syntax DellStateCapabilities Access Read-only Table 369.
Syntax DellVoltageType Access Read-only Table 373. Voltage Probe Location Name Name voltageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.8 Description Defines the location of the voltage probe in this chassis. Syntax DellString Access Read-only Table 374. Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.9 Description Defines the value of the voltage probe’s upper nonrecoverable threshold.
Syntax DellSigned32BitRange Access Read-only Table 379. Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.14 Description Defines the value of the voltage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 380. Voltage Probe Capabilities Name voltageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
, amperageProbeIndex Table 384. Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 385. Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.2 Description Defines the index of amperage probes in this chassis. Syntax DellObjectRange Access Read-only Table 386.
Description Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amperes.
Table 394. Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11 Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 395. Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Syntax DellAmperageDiscreteReading (Amperage Probe Discrete Reading) Access Read-only AC Power Switch Table Table 400. AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible Table 401. AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry.
Table 405. AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch. Syntax DellACPowerSwitchSettings Access Read-only Table 406. AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5 Description Defines the redundancy status of this AC power switch. Syntax DellStatusRedundancy Access Read-only Table 407.
AC Power Cord Table Table 411. AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table. Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible Table 412. AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.1 Description Defines the AC Power Cord Table entry.
Table 416. AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord. Syntax DellACPowerCordStateSettings Access Read-only Table 417. AC Power Cord Status Name aCPowerCordStatus Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5 Description Defines the status of this AC power cord. Syntax DellStatus Access Read-only Table 418.
Index batteryChassisIndex, batteryIndex Table 422. Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1 Description Defines the index (one-based) of the chassis that contains the battery. Syntax DellObjectRange Access Read-only Table 423. Battery Index Name batteryIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2 Description Defines the index (one-based) of the battery. Syntax DellObjectRange Access Read-only Table 424.
Access Read-only Table 428. Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery. Syntax DellString Access Read-only Power Usage Table Table 429. Power Usage Table Name powerUsageTable Object ID 1.3.6.1.4.1.674.10892.1.600.60 Description Defines the Power Usage Table. Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Table 430.
Description Defines the state capabilities of the power usage information. Syntax DellStateCapabilities Access Read-only Table 434. Power Usage State Settings Name powerUsageStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.4 Description Defines the state settings of the power usage information. Syntax DellStateSettings Access Read-only Table 435. Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 439. Power Usage Peak Watts Name powerUsagePeakWatts Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.9 Description Defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Table 440. Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Description Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. Syntax DellDateName Access Read-only Table 445. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Table 446.
Table 450. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Table 451. Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Syntax DellObjectRange Access Read-only Table 456. Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Table 457. Power Profile Setting Name powerProfileSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.4 Description Defines the power profile setting. Syntax DellPowerProfileType Access Read-only Table 458.
Table 461. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.8 Description Defines the custom memory power and performance management setting for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Table 462. Power Profile Custom Fan Management Capabilities Name powerProfileCustomFanManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.
onLine(2) The power supply’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The power supply’s state is not ready. fanFailure(8) The power supply fan has failed. onlineAndFanFailure(10) The power supply is online and indicating that its fan is not working. powerSupplyIsON(16) The power supply is indicating that it is on. powerSupplyIsOk(32) The power supply is indicating that it is OK.
presenceDetected(1) The power supply’s presence is detected. psFailureDetected(2) The power supply failure is detected. predictiveFailure(4) The power supply sensor detects predictive failure psACLost(8) The power supply’s AC power is lost. acLostOrOutOfRange(16) The power supply’s AC power is lost or out of range. acOutOfRangeButPresent(32) The power supply’s AC power is present, but it is out of range. configurationError(64) The power supply sensor detects a configuration error. Table 468.
voltageProbeTypeIsDiscrete(16) The voltage probe type is a voltage probe with discrete reading. Table 470. Voltage Probe Discrete Reading Variable Name: DellVoltageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value voltageIsGood(1) The voltage probe discrete reading is good. voltageIsBad(2) The voltage probe discrete reading is bad. Table 471.
amperageProbeTypeIsSystemWatts(26) The amperage probe type is system probe with reading in Watts. Table 472. Amperage Probe Discrete Reading Variable Name: DellAmperageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value amperageIsGood(1) The amperage probe discrete reading is good. amperageIsBad(2) The amperage probe discrete reading is bad. Table 473.
Table 476. AC Power Cord State Capabilities Variable Name: DellACPowerCordStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s capabilities are unknown. onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 477.
Table 480. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 481. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance. osControl(2) Power profile type is OS control.
maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. . mhz1067(4) Memory power and performance is 1067 MHz. mhz800(8) Memory power and performance is 800 MHz. minPower(16) Memory power and performance management type is Minimum Power. Table 484.
Syntax TableEntry Access Not accessible Index coolingUnitchassisIndex , coolingUnitIndex Table 487. Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Table 488. Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units.
Table 492. Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy. Syntax DellObjectRange Access Read-only Table 493. Cooling Unit Name Name coolingUnitName Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.7 Description Defines the cooling unit name in this chassis. Syntax DellString Access Read-only Table 494.
Table 497. Cooling Device Chassis Index Name coolingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 498. Cooling Device Index Name coolingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.2 Description Defines the index of cooling devices in this chassis. Syntax DellObjectRange Access Read-only Table 499.
cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 503. Cooling Device Type Name coolingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7 Description Defines the cooling device type. Syntax DellCoolingDeviceType (Cooling Device Type) Access Read-only Table 504. Cooling Device Location Name Name coolingDeviceLocationName Object ID 1.3.6.1.4.1.674.
Description Defines the user-assigned value of the fan’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 509. Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Table 510.
Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the discrete reading for the cooling device.
Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only Table 520. Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-only Table 521. Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Table 525. Temperature Probe Upper Nonrecoverable Threshold Name temperatureProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9 Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 526. Temperature Probe Upper Critical Threshold Name temperatureProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Table 531. Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Table 532. Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16 Description Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete.
coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads InRPM(3) The cooling device subtype is a fan that reads in RPMs. coolingDeviceSubTypeIsAFanReadsONor OFF(4) The cooling device subtype is a fan that reads 0 (off) or 1 (on). coolingDeviceSubTypeIsAPowerSupply FanThatReadsinRPM(5) The cooling device subtype is a power supply fan that reads in RPMs.
Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Table 538. Remote Flash BIOS Table Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.900.10 Description Defines the Remote Flash BIOS Table. Syntax RemoteFlashBIOSTableEntry Access Not accessible Table 539. Remote Flash BIOS Table Entry Name remoteFlashBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.900.10.1 Description Defines the Remote Flash BIOS Table entry.
Table 543. Remote Flash BIOS State Settings Unique Name remoteFlashBIOSStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.4 Description Defines the state and settings of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateSettingsUnique (Remote Flash BIOS State Settings) Access Read-only Table 544. Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.
Table 548. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown. enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The remote flash BIOS can be set to indicate not ready. cancelCapable(8) Flash of BIOS can be canceled.
completionCodeIsNo12VoltSet(11) 12 volts (V) could not be set. completionCodeIsNo12VoltRemoval(12) 12 V could not be removed. completionCodeIsFlashMemoryFailed (13) A flash memory failure occurred. completionCodeIsGeneralFailure(14) A general failure occurred. completionCodeIsDataMiscompare(15) A data miscompare error occurred. completionCodeIsNoImageFound(16) The flash BIOS image could not be found in memory. completionCodeIsNoUpdatePerformed (17) No update operation has been performed.
, pointingPortIndex Table 553. Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 554. Pointing Port Index Name pointingPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2 Description Defines the index of the pointing ports in this chassis. Syntax DellObjectRange Access Read-only Table 555.
Table 558. Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6 Description Defines the security settings of the pointing port. Syntax DellPortSecurityState Access Read-only Table 559. Pointing Port Connector Type Name pointingPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.7 Description Defines the connector type of the pointing port.
Description Defines the Keyboard Port Table entry. Syntax KeyboardPortTableEntry Access Not accessible Index keyboardPortchassisIndex , keyboardPortIndex Table 564. Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 565. Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.
Syntax DellStatus Access Read-only Table 569. Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port. Syntax DellPortSecurityState Access Read-only Table 570. Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.7 Description Defines the connector type of the keyboard port.
Table 574. Processor Port Table Entry Name processorPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1 Description Defines the Processor Port Table entry. Syntax ProcessorPortTableEntry Access Not accessible Index processorPortchassisIndex , processorPortIndex Table 575. Processor Port Chassis Index Name processorPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.1 Description Defines the index (one-based) of this chassis.
Table 579. Processor Port Status Name processorPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.5 Description Defines the status of the processor port. Syntax DellStatus Access Read-only Table 580. Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Table 581.
Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Table 585. Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry. Syntax MemoryDevicePortTableEntry Access Not accessible Index memoryDevicePortchassisIndex , memoryDevicePortIndex Table 586.
Syntax DellStateSettings Access Read-only Table 590. Memory Device Port Status Name memoryDevicePortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.5 Description Defines the status of the memory device port. Syntax DellStatus Access Read-only Table 591. Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6 Description Defines the security settings of the memory device port.
Table 595. Memory Device Port Physical Memory Array Index Reference Name memoryDevicePortPhysicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.10 Description Defines the index to the associated physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 596. Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.
Access Read-only Table 600. Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Table 601. Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Table 602.
Table 605. Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Monitor Port Connector Types) Access Read-only Table 606. Monitor Port Name Name monitorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.8 Description Defines the name of the monitor port. Syntax DellString Access Read-only Table 607.
Table 610. SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1 Description Defines the index (one-based) of this chassis Syntax DellObjectRange Access Read-only Table 611. SCSI Port Index Name sCSIPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.2 Description Defines the index of the SCSI ports in this chassis. Syntax DellObjectRange Access Read-only Table 612. SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.
Syntax DellPortSecurityState Access Read-only Table 616. SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See SCSI Port Connector Types) Access Read-only Table 617. SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port. Syntax DellString Access Read-only Table 618.
, parallelPortIndex Table 621. Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 622. Parallel Port Index Name parallelPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.2 Description Defines the index of the parallel ports in this chassis. Syntax DellObjectRange Access Read-only Table 623.
Table 626. Parallel Port Security State Name DellPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.6 Description Defines the security state of the parallel port. Syntax DellStatus Access Read-only Table 627. Parallel Port Connector Type Name parallelPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.7 Description Defines the connector type of the parallel port. Syntax DellParallelPortConnectorType Access Read-only Table 628.
Syntax DellUnsigned64BitRange Access Read-only Table 632. Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Table 633. Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port.
Syntax DellObjectRange Access Read-only Table 637. Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis. Syntax DellObjectRange Access Read-only Table 638. Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3 Description Defines the capabilities of the serial port. Syntax DellStateCapabilities Access Read-only Table 639.
Table 642. Serial Port Connector Type Name serialPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.7 Description Defines connector type of the serial port. Syntax DellSerialPortConnectorType Access Read-only Table 643. Serial Port Name Name serialPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8 Description Defines the name of the serial port. Syntax DellString Access Read-only Table 644. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.
Syntax DellUnsigned8BitRange Access Read-only Universal Serial Bus (USB) Port Table Table 648. Universal Serial Bus (USB) Port Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible Table 649. USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry.
Access Read-only Table 653. USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-only Table 654. USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5 Description Defines the state of the USB port. Syntax DellStatus Access Read-only Table 655. USB Port Security State Name uSBPortSecurityState Object ID 1.3.6.1.4.1.
Table 658. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type :Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown. connectorPortTypeIsSerial(3) The pointing port connector type is serial. connectorPortTypeIsPS2(4) The pointing port connector type is a Personal System/2 (PS/2).
Table 660. Processor Port Connector Types Variable Name : DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown. connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board.
connectorPortTypeIsSODIMM(13) The memory device port connector type is a small outline, dual in-line memory module (SODIMM). connectorPortTypeIsSRIMM(14) The memory device port connector type is a SRIMM. Table 662.
• SD Card Unit Table • SD Card Device Table Pointing Device Table Table 664. Pointing Device Table Name pointingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.10 Description Defines the Pointing Device Table. This group of objects references the Pointing Port Index (Pointing Port Index). Syntax SEQUENCE OF PointingDeviceTableEntry Access Not accessible Table 665. Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.
Table 669. Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device. Syntax DellStateSettings Access Read-only Table 670. Pointing Device Status Name pointingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.5 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only Table 671.
Access Not accessible Table 675. Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1 Description Defines the Keyboard Device Table entry. Syntax KeyboardDeviceTableEntry Access Not accessible Index keyboardDevicechassisIndex , keyboardDeviceIndex Table 676. Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis.
Table 680. Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Table 681. Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Table 682.
Index processorDevicechassisIndex , processorDeviceIndex Table 686. Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 687. Processor Device Index Name processorDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2 Description Defines the index of the processor device in this chassis.
Description Defines the index to the associated processor port in this chassis. Syntax DellObjectRange Access Read-only Table 692. Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Processor Device Type) Access Read-only Table 693. Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Table 697. Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 698. Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Access Read-only Table 703. Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 704. Processor Device Thread Count Name processorDeviceThreadCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.19 Description Defines the number of processor threads detected for the processor device.
Bit Position Meaning if Set Bit 3 Hyper-Threading (HT) supported Syntax DellUnsigned16BitRange Access Read-only Table 707. Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Processor Device Status Table Table 711. Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.32 Description Defines the Processor Device Status Table. Syntax SEQUENCE OF ProcessorDeviceStatusTableEntry Access Not accessible Table 712. Processor Device Status Table Entry Name processorDeviceStatusTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1 Description Defines the Processor Device Status Table Entry.
Table 716. Processor Device Status State Settings Name processorDeviceStatusStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.4 Description Defines the state settings of the processor device status probe. Syntax DellStateSettings Access Read-only Table 717. Processor Device Status Name processorDeviceStatusStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.5 Description Defines the status of the processor device status probe.
Access Not accessible Table 722. Cache Device Table Entry Name cacheDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1 Description Defines the Cache Device Table entry. Syntax CacheDeviceTableEntry Access Not accessible Index cacheDevicechassisIndex , cacheDeviceIndex Table 723. Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis.
Table 727. Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device. Syntax DellStatus Access Read-only Table 728. Cache Device Processor Device Index Reference Name cacheDeviceprocessorDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.6 Description Defines the index number of the processor device with which this cache device is associated.
Access Read-only Table 733. Cache Device Level Name cacheDeviceLevel Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.11 Description Defines the level of the cache device. Syntax DellCacheDeviceLevel (See Cache Device Level) Access Read-only Table 734. Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown.
Description Defines if the cache device is socketed. Syntax DellBoolean Access Read-only Table 739. Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device. Syntax DellCacheDeviceECCType (See Cache Device ECC Type) Access Read-only Table 740. Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.
Table 744. Memory Device Table Entry Name memoryDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1 Description Defines the Memory Device Table entry. Syntax MemoryDeviceTableEntry Access Not accessible Index memoryDevicechassisIndex , memoryDeviceIndex Table 745. Memory Device Chassis Index Name memoryDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 746.
Syntax DellStatus Access Read-only Table 750. Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Table 751. Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device.
Table 755. Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Memory Device Type Details) Access Read-only Table 756. Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12 Description Defines the form factor of the memory device.
Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Table 761. Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Table 762.
Table 765. Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.21 Description Defines the manufacturer of the memory device. Syntax DellString Access Read-only Table 766. Memory Device Part Number Name Name memoryDevicePartNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22 Description Defines the manufacturer's part number for the memory device. Syntax DellString Access Read-only Table 767.
Value Meaning deviceRankIsUn known(1) Rank is unknown deviceRankIsSi ngle(2) Rank is Single deviceRankIsDu al(4) Rank is Dual deviceRankIsQu ad(8) Rank is Quad deviceRankIsOc tal(16) Rank is Octal deviceRankIsHe xa(32) Rank is Hexa Syntax DellMemoryDeviceRank Access Read-only Table 771. Memory Device Extended Size NOTE: This attribute replaces the memoryDeviceSize. Name memoryDeviceExtendedSize Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Description Defines the Memory Device Mapped Address Table. Syntax SEQUENCE OF MemoryDeviceMappedAddressTableEntry Access Not accessible Table 775. Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry. Syntax MemoryDeviceMappedAddressTableEntry Access Not accessible Index memoryDeviceMappedAddresschassisIndex , memoryDeviceMappedAddressIndex Table 776.
Access Read-only Table 780. Memory Device Mapped Address Status Name memoryDeviceMappedAddressStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.5 Description Defines the status of the memory device mapped address. Syntax DellStatus Access Read-only Table 781. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address.
Description Defines the physical starting address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Table 786. Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11 Description Defines the physical ending address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Generic Device Table Table 787.
Access Read-only Table 791. Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3 Description Defines the capabilities of the generic device. Syntax DellStateCapabilities Access Read-only Table 792. Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-only Table 793.
Access Read-only PCI Device Table Table 797. PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible Table 798. PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1 Description Defines the PCI Device Table entry.
Table 802. PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4 Description Defines the state of the PCI device. Syntax DellStateSettings Access Read-only Table 803. PCI Device Status Name pCIDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.5 Description Defines the status of the PCI device. Syntax DellStatus Access Read-only Table 804. PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.
Table 808. PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10 Description Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 809. PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault.
Table 813. PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.2 Description Defines the index (one-based) of the PCI device configuration in this chassis. Syntax DellObjectRange Access Read-only Table 814. PCI Device Configuration Space State Capabilities Name pCIDeviceConfigurationSpaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.3 Description Defines the capabilities of the PCI device configuration.
Table 819. PCI Device Configuration Space Device Number Name pCIDeviceConfigurationSpaceDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.8 Description Defines the device number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only Table 820. PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis.
Description Defines the index (one-based) of the chassis that contains the network device. Syntax DellObjectRange Access Read-only Table 825. Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device. Syntax DellObjectRange Access Read-only Table 826. Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Description Defines the name of the vendor of the network device. Syntax DellString Access Read-only Table 831. Network Device Service Name Name networkDeviceServiceName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.8 Description Defines the service name of the network device. Syntax DellString Access Read-only Table 832. Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Table 837. Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device. Syntax IpAddress Access Read-only Table 838.
Table 842. Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 843. Network Device IRQ Name networkDeviceIRQ Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.20 Description Defines the interrupt request number of the network device. Syntax DellUnsigned32BitRange Access Read-only Table 844.
Table 848. Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (See Network Device RDMA Capability Flags) Access Read-only Table 849. Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
3 - Unknown Syntax DellNetworkDeviceNParEPEnabled Access Read-only Managed System Services Device Table Table 854. Managed System Services Device Table Name Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Table 855. Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.
Access Read-only Table 859. Managed System Services Device Type Name managedSystemServicesDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4 Description Defines the type of the managed system services device. Syntax DellManagedSystemServicesDeviceType (See Managed System Services Device Type) Access Read-only Table 860. Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
Table 864. SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only Table 865. SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.2 Description Defines the index (one-based) of the SD Card unit. Syntax DellObjectRange Access Read-only Table 866.
Access Read-only Table 870. SD Card Unit Name Name sdCardUnitName Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7 Description Defines the name of the SD Card unit. Syntax DellString Access Read-only Table 871. SD Card Unit Status Name sdCardUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8 Description Defines the status of the SD Card unit. Syntax DellStatus Access Read-only SD Card Device Table Table 872. SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.
Table 875. SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only Table 876. SD Card Device Status Name sdCardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3 Description Defines the status of the SD Card device. Syntax DellStatus Access Read-only Table 877. SD Card Device Type Name sdCardDeviceType Object ID 1.3.6.1.4.1.674.10892.
Table 881. SD Card Device Card Present Name sdCardDeviceCardPresent Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.8 Description Defines whether the SD Card is present for the SD Card device. Syntax DellBoolean Access Read-only Table 882. SD Card Device Card State Name sdCardDeviceCardState Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.9 Description Defines the state of the SD Card. Syntax DellSDCardDeviceCardState Access Read-only Table 883.
Access Read-only Device Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 887. Pointing Device Type Variable Name: DellPointingDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2 ) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse. deviceTypeIsATrackBal l(4) Device type is a track ball.
processorDisabled(2 56) The processor is disabled terminatorPresent(5 12) The terminator is Present processorThrottled( 1024) The processor is throttled Table 890. Processor Device Type Variable Name:DellProcessorDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1 ) The processor device type is not one of the following values: deviceTypeIsUnknow n(2) The processor device type is unknown.
processorUpgradeIsB ySlotA(11) Upgrade is by Slot A. processorUpgradeIsB ySlotM(12) Upgrade is by Slot M. processorUpgradeIsB yScoket423(13) Upgrade is by Socket 423. processorUpgradeIsB ySocketA(14) Upgrade is by Socket A (Socket 462). processorUpgradeIsB ySocket478(15) Upgrade is by Socket 478. processorUpgradeIsB ySocket754(16) Upgrade is by Socket 754. processorUpgradeIsB ySocket940(17) Upgrade is by Socket 940. processorUpgradeIsB ySocket939(18) Upgrade is by Socket 939.
deviceFamilyIS8087( 7) The processor family is 8087. deviceFamilyIs8028 7(8) The processor family is 80287. deviceFamilyIs8038 7(9) The processor family is 80387. deviceFamilyIs8048 7(10) The processor family is 80487. deviceFamilyIsPenti um(11) The processor family is Intel Pentium. deviceFamilyIsPenti umPro(12) The processor family is Pentium Pro. deviceFamilyIsPenti um2(13) The processor family is Pentium II. deviceFamilyIsPenti umMMX(14) The processor family is Pentium MMX.
deviceFamilyIsK6-2P lus(31) The processor family is K6-2+. deviceFamilyIsPower PC(32) The processor family is Power PC. deviceFamilyIsPower PC601(33) The processor family is Power PC 601. deviceFamilyIsPower PC603(34) The processor family is Power PC 603. deviceFamilyIsPower PC603Plus (35) The processor family is Power PC 603+. deviceFamilyIsPower PC604(36) The processor family is Power PC 604. deviceFamilyIsPower PC620(37) The processor family is Power PC 620.
deviceFamilyIsAMDAt hlonIIDualM obileM(58) The processor family is AMD Athlon II Dual-Core Mobile M Processor Family. deviceFamilyIsAMDOp teron6100 (59) The processor family is AMD Opteron 6100 Series Processor. deviceFamilyIsAMDOp teron4100 (60) The processor family is AMD Opteron 4100 Series Processor. deviceFamilyIsAMDOp teron6200 (61) The processor family is AMD Opteron 6200 Series Processor. deviceFamilyIsAMDOp teron4200 (62) The processor family is AMD Opteron 4200 Series Processor.
deviceFamilyIs6801 0(99) The processor family is 68010. deviceFamilyIs6802 0(100) The processor family is 68020. deviceFamilyIs6803 0(101) The processor family is 68030. deviceFamilyIsHobbi t(112) The processor family is Hobbit. deviceFamilyIsCruso e5000(120) The processor family is Crusoe 5000. deviceFamilyIsCruso e3000(121) The processor family is Crusoe 3000. deviceFamilyIsEffic eon8000 (122) The processor family is Efficeon 8000. deviceFamilyIsWeite k(128) The processor family is Weitek.
deviceFamilyIsAMDAt hlonX2DualC ore(143) The processor family is AMD Athlon X2 Dual-Core. deviceFamilyIsPARISC(144) The processor family is PA-RISC. deviceFamilyIsPARISC8500(145) The processor family is PA-RISC 8500. deviceFamilyIsPARISC8000(146) The processor family is PA-RISC 8000. deviceFamilyIsPARIS C7300LC( 147) The processor family is PA-RISC 7300LC. deviceFamilyIsPARISC7200(148) The processor family is PA-RISC 7200.
deviceFamilyIsDualC oreIntelXeon7200(17 2) The processor family is Dual-Core Intel Xeon processor 7200 Series. deviceFamilyIsQuadC oreIntelXeon7300(17 3) The processor family is Quad-Core Intel Xeon processor 7300 Series. deviceFamilyIsQuadC oreIntelXeon7400(17 4) The processor family is Quad-Core Intel Xeon processor 7400 Series. deviceFamilyIsMulti CoreIntelXeon7400(1 75) The processor family is Multi-Core Intel Xeon processor 7400 Series. deviceFamilyIsM1(17 6) The processor family is M1.
deviceFamilyIsIntel Core2DuoMob ile(196) The processor family is Intel Core2 Duo mobile processor. deviceFamilyIsIntel Core2SoloMo bile(197) The processor family is Intel Core2 Solo mobile processor. deviceFamilyIsIntel Corei7(198) The processor family is Intel Core i7 processor. deviceFamilyIsDualC oreIntelCel eron(199) The processor family is Dual-Core Intel Celeron Processor. deviceFamilyIsIBM39 0(200) The processor family is IBM390. deviceFamilyIsG4(20 1) The processor family is G4.
deviceFamilyIsDualC oreIntelXeo n7xxx(221) The processor family is Dual-Core Intel Xeon processor 7xxx Series. deviceFamilyIsQuadC oreIntelXeo n7xxx(222) The processor family is Quad-Core Intel Xeon processor 7xxx Series. deviceFamilyIsMulti CoreIntelXe on7xxx(223) The processor family is Multi-Core Intel Xeon processor 7xxx Series. deviceFamilyIsMulti CoreIntelXe on3400(224) The processor family is Multi-Core Intel Xeon processor 3400 Series.
deviceTypeIsOther(1 ) System cache type is not one of the following: deviceTypeIsUnknow n(2) System cache type is unknown. deviceTypeIsInstruc tion(3) System cache type is instruction. deviceTypeIsData(4) System cache type is data. deviceTypeIsUnifie d(5) System cache type is both instruction and data. Table 894.
other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 897. Cache Device ECC Type Variable Name:DellPointingDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1 ) Device type is not one of the following: deviceTypeIsUnknow n(2) Device type is unknown.
deviceAssociativity IsSixteenWaySetAsso ciative(8) Device is sixteen-way set associative. deviceAssociativity Is12WaySetAssociati ve(9) Device is 12-way Set-Associative. deviceAssociativity Is24WaySetAssociati ve(10) Device is 24-way Set-Associative. deviceAssociativity Is32WaySetAssociati ve(11) Device is 32-way Set-Associative. deviceAssociativity Is48WaySetAssociati ve(12) Device is 48-way Set-Associative. deviceAssociativity Is64WaySetAssociati ve(13) Device is 64-way Set-Associative.
deviceSRAMTypeIsAsy nchronous(7) Device SRAM type is asynchronous. Table 901. Memory Device Type Form Factor Variable Name:DellMemoryDeviceFormFactor Data Type:Integer Possible Data Values Meaning of Data Value deviceFormFactorIsO ther(1) Device form factor is not one of the following: deviceFormFactorIsU nknown(2) Device form factor is unknown. deviceFormFactorIsS IMM(3) Device form factor is SIMM. deviceFormFactorIsS IP(4) Device form factor is SIP.
deviceTypeIsEDRAM(4 ) Device type is EDRAM. deviceTypeIsVRAM(5) Device type is VRAM. deviceTypeIsSRAM(6) Device type is SRAM. deviceTypeIsRAM(7) Device type is RAM. deviceTypeIsROM(8) Device type is ROM. deviceTypeIsFLASH(9 ) Device type is FLASH. deviceTypeIsEEPROM( 10) Device type is EEPROM. deviceTypeIsFEPROM( 11) Device type is FEPROM. deviceTypeIsEPROM(1 2) Device type is EPROM. deviceTypeIsCDRAM(1 3) Device type is CDRAM. deviceTypeIs3DRAM(1 4) Device type is 3DRAM.
deviceTypeDetailIsS taticColum n(16) The detailed device type is static column. deviceTypeDetailIsP seudoStati c(32) The detailed device type is pseudo-static. deviceTypeDetailIsR AMBUS(64) The detailed device type is RAMBUS. deviceTypeDetailIsS ynchronous (128) The detailed device type is synchronous. deviceTypeDetailIsC MOS(256) The detailed device type is CMOS. deviceTypeDetailIsE DO(512) The detailed device type is EDO.
Possible Data Values Meaning of Data Value (0) Memory device has no faults. eccSingleBitCorrectionWa Memory device has exceeded the Correctable Memory rningRate(1) Event warning rate. eccSingleBitCorrectionFa Memory device has exceeded the Correctable Memory ilureRate(2) Event failure rate. eccMultiBitFault(4) Memory device has encountered an Uncorrectable Memory Event. eccSingleBitCorrectionLo Correctable Memory Event logging for memory device ggingDisabled (8) has been disabled.
hardwareNotReady(13 ) Hardware is not ready. Table 907. Network Device Teaming Flags Variable Name:DellNetworkDeviceTeamingFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value undefined(0) Teaming flags are undefined. noTeam(1) Device is not part of any team. teamingEnabled(2) Teaming is enabled. adapterFaultToleran ceMode(4) Adapter fault tolerance teaming mode.
driverNotRespondin g(16) Querying for RDMA capability is supported but driver did not respond to query. Table 910. Network Device iSCSI Capability Flags Variable Name:DellNetworkDeviceiSCSICapabilityFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for iSCSI capability is not supported. unknown(1) Querying for iSCSI capability is supported but query returned an error.
Possible Data Values Meaning of Data Value baseDevice(0) Device type is base device. optionalDevice(1) Device type is optional device. Table 914. SD Card Device Type Variable Name:DellSDCardDeviceType Data Type:Integer Possible Data Values Meaning of Data Value other(1) Device type is other. unknown(2) Device type is unknown. hypervisor(3) Device type is Hypervisor. vFlash(4) Device type is Virtual Flash (vFlash.) Table 915.
active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode. Table 918. SD Card Device Card Licensed Variable Name:DellSDCardDeviceCardLicensed Data Type:Integer Possible Data Values Meaning of Data Value unlicensed(0) SD card is not licensed by system vendor. licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready.
Index systemSlotchassisIndex , systemSlotIndex Table 921. System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 922. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 923.
Table 926. System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only Table 927. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType (System Slot Type) Access Read-only Table 928.
Description Defines the system slot category. Syntax DellUnsigned32BitRange Access Read-only Table 932. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth (Hot-Plug Bus Width) Access Read-only Table 933. System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent. systemSlotHotPlugCanSignal AdapterPresent(32) Adapter (card) present in slot (may not be powered) can be detected. systemSlotHotPlugCanSignal PowerButtonPressed(64) The system slot power button can be pressed to signal a toggle of the power state. canSupportAllHotPlugCapabi lities(126) The system slot can support all hot-plug capabilities.
systemSlotProvides5Volts(128) The system slot provides a 5-V supply. systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V supply. systemSlotIsShared(512) The slot’s opening is shared with another slot. systemSlotSupportsCard16(1024) The system slot supports PC Card-16. systemSlotSupportsCardBus(2048) The system slot supports CardBus. systemSlotSupportsZoomVideo(4096) The system slot supports zoom video.
systemSlotIsAGP(15) The system slot is an Advanced Graphics Port (AGP). systemSlotIsAGP2X(16) The system slot is an AGP 2x card. systemSlotIsAGP4X(17) The system slot is an AGP 4x card. systemSlotIsPC98C20(18) The system slot is a PC-98/C20. systemSlotIsPC98C24(19) The system slot is a PC-98/C24. systemSlotIsPC98E(20) The system slot type is PC-98/E. systemSlotIsPC98LocalBus(21) The system slot type is a PC-98 local bus. systemSlotIsPC98Card(22) The system slot type is a PC-98 card.
systemSlotLengthIsUnknown(2) The system slot length is unknown. systemSlotLengthIsShort(3) The system slot length is short. systemSlotLengthIsLong(4) The system slot length is long. Table 940. System Slot Category Variable Name: DellSystemSlotCategory Data Type: Integer Possible Data Values Meaning of Data Value systemSlotCategoryIsOther(1) The system slot category is not one of following: systemSlotCategoryIsUnknown(2) The system slot category is unknown.
Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
Index physicalMemoryArraychassisIndex , physicalMemoryArrayIndex Table 944. Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 945. Physical Memory Array Index Name physicalMemoryArrayIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Table 949. Physical Memory Array Use Name physicalMemoryArrayUse Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.6 Description Defines the use of the physical memory array. Syntax DellPhysicalMemoryArrayUse (See Physical Memory Array ECC Type Definitions) Access Read-only Table 950. Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array.
Table 954. Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 955. Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.16 Description This attribute defines the maximum size in Bytes of the physical memory array. Syntax DellUnsigned64BitRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses. The following object sets up the Physical Memory Array Mapped Table: Table 960. Physical Memory Array Mapped Table Name physicalMemoryArrayMappedTable Object ID 1.3.6.1.4.1.674.10892.1.1300.
Table 964. Physical Memory Array Mapped State Capabilities Name physicalMemoryArrayMappedStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.3 Description Defines the capabilities of the memory array mapped address. Syntax DellStateCapabilities Access Read-only Table 965. Physical Memory Array Mapped State Settings Name physicalMemoryArrayMappedStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.4 Description Defines the state of the memory array mapped address.
Syntax DellUnsigned64BitRange Access Read-only Table 970. Physical Memory Array Mapped Partition Width Name physicalMemoryArrayMappedPartitionWidth Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9 Description Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown.
Table 974. Physical Memory Configuration Index Name physicalMemoryConfigIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.2 Description Defines the index (one-based) of the physical memory configuration. Syntax DellObjectRange Access Read-only Table 975. Physical Memory Configuration State Capabilities Name physicalMemoryConfigStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.3 Description Defines the state capabilities of the physical memory configuration.
Syntax DellPhysicalMemoryConfigRedundantSettings Access Read-only Table 980. Physical Memory Configuration MOM Capabilities Name physicalMemoryConfigMOMCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.8 Description Defines the Memory Operating Mode capabilities of the physical memory. Syntax DellPhysicalMemoryConfigMOMCapabilities Access Read-only Table 981. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
Syntax DellObjectRange Access Read-only Table 985. Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Table 986. Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging.
Table 990. Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex , redundantMemoryUnitIndex Table 991. Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
Table 995. Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit. Syntax DellStatusRedundancy Access Read-only Table 996. Redundant Memory Unit Name Name redundantMemoryUnitName Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.6 Description Defines the name of the redundant memory unit. Syntax DellString Access Read-only Table 997.
, physicalMemoryCardIndex Table 1000. Physical Memory Card Chassis Index Name physicalMemoryCardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1001. Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card.
Table 1005. Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Table 1006. Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card. 2,147,483,647 indicates an unknown number of sockets.
memoryArrayUseIsSystemMemory(3) The memory array is system memory. memoryArrayUseIsVideoMemory(4) The memory array is video memory. memoryArrayUseIsFLASHMemory(5) The memory array is FLASH memory. memoryArrayUseIsNonVolatileRAMMemory(6) The memory array is nonvolatile RAM. memoryArrayUseIsCacheMemory(7) The memory array is cache memory. memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card.
Table 1012. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object not ready. redundantMemoryIsActive(8) Redundant memory is active (in use). enabledAndRedundantMemoryIsActive(10) Redundant memory is enabled and in use.
Table 1015. Physical Memory Logging Capabilities Variable Name: DellPhysicalMemoryLoggingCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging capabilities. unknown Capabilities(1) Logging capabilities are unknown. The logging capabilities are: enableCapable(2) Logging enable/disable using Simple Network Management Protocol (SNMP) is supported. Table 1016.
Description Defines the set of single devices in a chassis controlled by the BIOS. Syntax BiosSetUpControlTableEntry Access Not accessible Table 1018. BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex Table 1019.
Access Read-only Table 1023. BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5 Description Defines the setup BIOS name of the pointing device. Syntax DellString Access Read-only Table 1024. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock.
Table 1028. BIOS Setup Control Processor Serial Number Control Capabilities Name bSUCprocessorSerialNumberControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.10 Description Defines if the processor serial number can be returned. Syntax DellStateCapabilities Access Read-only Table 1029. BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Syntax DellSpeakerControlSettingsUnique (See Speaker Control Settings Unique) Access Read-only Table 1034. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 1035. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Read-only Table 1039. BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only Table 1040. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.22 Description Defines the capabilities of the boot sequence.
Table 1044. BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 1045. BIOS Setup Control Administrator Password Control Settings Unique Name bSUCadministratorPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.
Description Defines the capabilities of user password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 1050. BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32 Description Defines the control settings for user password control. Syntax DellBIOSPasswordControlSettingsUnique (See BIOS Password Control Settings ) Access Read-Only Table 1051.
Access Read-only Table 1055. BIOS Setup Control TPM Security Control Setting Name bSUCtpmSecurityControlSetting Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.37 Description Defines the BIOS setup control setting of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlSetting Access Read-only Table 1056. BIOS Setup Control TPM Security Control Status Name bSUCtpmSecurityControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Table 1060. SCSI Control Chassis Index Name sCSIControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1061. SCSI Control Index Name sCSIControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.2 Description Defines the index (one-based) of the SCSI controller in this chassis. Syntax DellObjectRange Access Read-only Table 1062.
Parallel Port Control Table Table 1066. Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table. Syntax ParallelPortControlTableEntry Access Not accessible Table 1067. Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry.
Table 1071. Parallel Port Control Settings Unique Name parallelPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.4 Description Defines the state of the parallel port. Syntax DellParallelPortControlSettingsUnique (See Parallel Port Control Settings) Access Read-only Table 1072. Parallel Port Control Status Name parallelPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.5 Description Defines the status of the parallel port.
Access Not accessible Table 1077. Serial Port Control Table Entry Name serialPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1 Description Defines the Serial Port Control Table entry. Syntax SerialPortControlTableEntry Access Not accessible Index serialPortControlchassisIndex , serialPortControlIndex Table 1078. Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.
Table 1082. Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Table 1083. Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port.
Table 1087. USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis. Syntax DellObjectRange Access Read-only Table 1088. USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3 Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only Table 1089. USB Control Settings Name usbControlSettings Object ID 1.3.6.
Access Not accessible Table 1093. IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1094. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis.
Table 1098. IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1099. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Table 1100. Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.
Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Table 1104. Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.3 Description Defines the capabilities of the diskette controller. Syntax DellDisketteControlCapabilitiesUnique Access Read-only Table 1105. Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.
Table 1109. Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex , networkInterfaceControlIndex Table 1110. Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
Description Defines the status of the NIC. Syntax DellStatus Access Read-only Table 1115. Network Interface Control Name Name networkInterfaceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.6 Description Defines the setup BIOS name of the NIC. Syntax DellString Access Read-only BIOS Setting Table These MIB objects enable you to track the BIOS settings for your system. NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems. Table 1116.
Description Defines the index (one based) of the BIOS setting. Syntax DellObjectRange Access Read-only Table 1120. BIOS Setting Name Name biosSettingName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.3 Description Defines the name of the BIOS setting. Syntax DisplayString Access Read-only Table 1121. BIOS Setting Display Name Name biosSettingDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.4 Description Defines the display name of the BIOS setting.
Description Defines the default value of the BIOS setting. Syntax DisplayString Access Read-only Table 1126. BIOS Setting Possible Values Name biosSettingPossibleValues Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.9 Description Defines the possible values of the BIOS setting. Syntax DisplayString Access Read-only Table 1127. BIOS Setting Display Order Name biosSettingDisplayOrder Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.
mediumCapable(8) Setup BIOS can set the speaker volume to medium. highCapable(16) Setup BIOS can set the speaker volume to high. allVolumeCapable(30) Setup BIOS can set the speaker volume to any of the three settings. Table 1131. Speaker Control Settings Unique Variable Name: DellSpeakerControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control state is unknown. enabled(2) Speaker control is enabled. low(4) Speaker control volume is low.
Table 1134. Boot Sequence Control Capabilities Unique Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence capabilities are unknown. bootFromDisketteFirstCapable (2) Setup BIOS can boot from a diskette first. bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first.
passwordControlEnabled(2) Setup BIOS has password changes enabled. passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 1138. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled.
lpt3Capable(16) Setup BIOS can support parallel port 3. lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3. allParallelPortCapable(30) Setup BIOS can support any of the three parallel ports. Table 1142. Parallel Port Control Settings Variable Name: DellParallelPortControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port state is unknown. enabled(2) Setup BIOS has enabled the parallel port.
com3Capable(16) Setup BIOS can support serial port 3. enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3. com4Capable(32) Setup BIOS can support serial port 4. enableAndCom4Capable(34) Setup BIOS is capable of enabling serial port 4. autoConfigCapable(64) Setup BIOS is capable of autoconfiguring all serial ports. com1OrCom3CapableAndAuto ConfigCapable(86) Setup BIOS has enabled autoconfiguration of COM1 and COM3 serial ports.
Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown. disketteControlAutoConfigEnabled OrEnabled(2) Diskette control is set as autoconfigurable or enabled. Table 1148. Network Interface Control Capabilities Variable Name: DellNetworkInterfaceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Unknown setup BIOS network interface capabilities. enableCapable(2) Setup BIOS is capable of enabling the network interface.
LRA Group Tables The following management information base (MIB) tables define LRA variable attributes: • LRA Global Settings Table • LRA Action Table LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator. Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilitiesUnique.
Table 1155. LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings are disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only Table 1156. LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.
Access Not accessible Table 1160. LRA Action Table Entry Name lRAActionTableTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1 Description Defines the LRA Action Table entry. Syntax LRAActionTableTableEntry Access Not accessible Index lRAActionTablechassisIndex , lRAActionTableActionNumberIndex Table 1161. LRA Action Table Chassis Index Name lRAActionTablechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.1 Description Defines the index (one-based) of this chassis.
• 1704 — battery failure action definition Syntax DellUnsigned16BitRange Access Read-only Table 1163. LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the execute application value is set, provides the following user-assignable LRA information: • • Name of the user application executable path File name to execute Syntax DisplayString (SIZE (0..256) Access Read-only Table 1164.
Table 1166. LRA Thermal Shutdown Capabilities Unique Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LRA has no thermal shutdown capabilities. Unknown capabilities(1) The LRA’s thermal shutdown capabilities are unknown. enableCapable(2) The LRA can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
• Cost of Ownership Table • COO Service Contract Table • COO Cost Event Log Table • COO Warranty Table • COO Lease Information Table • COO Schedule Number Table • COO Options Table • COO Maintenance Table • COO Repair Table • COO Support Information Table • COO Trouble Ticket Table Cost of Ownership Table The following MIB object sets up the Cost of Ownership Table. Table 1168. Cost of Ownership Name cooTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Access Read-only Table 1172. COO Acquisition Purchase Cost Name cooAquisitionPurchaseCost Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.3 Description Defines the purchase cost of the system. Syntax DellUnsigned32BitRange Access Read-only Table 1173. COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-only Table 1174.
Table 1177. COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-only Table 1178. COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.9 Description Specifies whether the purchase of this system was expensed.
Syntax DellDateName Access Read-only Table 1183. COO Extended Warranty End Date Name Name cooExtendedWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.14 Description Defines the extended warranty end date for this system. Syntax DellDateName Access Read-only Table 1184. COO Extended Warranty Cost Name cooExtendedWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.15 Description Defines the extended warranty cost date for this system.
Table 1188. COO Hazardous Waste Code Name Name cooHazardousWasteCodeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.19 Description Defines the hazardous waste code for this system. Syntax DellCostofOwnershipString Access Read-only Table 1189. COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1190.
Syntax DellCostofOwnershipString Access Read-only Table 1194. COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.25 Description Defines the name of the person who can sign the authorization for service. Syntax DellCostofOwnershipString Access Read-only Table 1195. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
Table 1199. COO Box System Name Name cooBoxSystemName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.30 Description Defines the name of the system. Syntax DellCostofOwnershipString Access Read-only Table 1200. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-only Table 1201.
Syntax DellUnsigned32BitRange Access Read-only Table 1205. COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-only Table 1206. COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
Access Not accessible Table 1210. COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1 Description Defines the COO Service Contract Table entry. Syntax CooServiceContractTableEntry Access Not accessible Index cooServiceContractchassisIndex , cooServiceContractIndex Table 1211. COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.
Access Read-only Table 1215. COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5 Description Defines the name of the service contract type for this system. Syntax DellCostofOwnershipString Access Read-only Table 1216. COO Service Contract Vendor Name Name cooServiceContractVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.6 Description Defines the name of the service contract provider for this system.
Syntax DellObjectRange Access Read-only Table 1220. COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.2 Description Defines the index (one-based) of the cost event log. Syntax DellObjectRange Access Read-only Table 1221. COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only Table 1222.
Table 1225. COO Warranty Table Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible Table 1226. COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1 Description Defines the COO Warranty Table entry. Syntax CooWarrantyTableEntry Access Not accessible Index cooWarrantychassisIndex , cooWarrantyIndex Table 1227.
Table 1230. COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty. Syntax DellUnsigned32BitRange Access Read-only Table 1231. COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.5 Description Defines the warranty duration type for the system. Syntax DellCOODayMonthDurationType Access Read-only Table 1232.
Table 1235. COO Lease Information Table Entry Name cooLeaseInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1 Description Defines the COO Lease Information Table entry. Syntax CooLeaseInformationTableEntry Access Not accessible Index cooLeaseInformationchassisIndex , cooLeaseInformationIndex Table 1236. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.
Table 1240. COO Lease Information Buyout Amount Name cooLeaseInformationBuyOutAmount Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.5 Description Defines the balance purchase price for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1241. COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system.
Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible Table 1246. COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry. Syntax CooScheduleNumberTableEntry Access Not accessible Index cooScheduleNumberchassisIndex , cooScheduleNumberIndex Table 1247.
Syntax DellUnsigned32BitRange Access Read-only Table 1251. COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5 Description Describes the schedule number information. Syntax DellCostofOwnershipString Access Read-only COO Options Table Table 1252. COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.70 Description Defines the COO Options Table.
Syntax DellObjectRange Access Read-only Table 1256. COO Options State Name cooOptionsState Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3 Description Defines the option information state for this system. Syntax DellStateSettings Access Read-only Table 1257. COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system.
, cooMaintenanceIndex Table 1261. COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1262. COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information. Syntax DellObjectRange Access Read-only Table 1263.
Table 1266. COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name. Syntax DellStateSettings Access Read-only Table 1267. COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.7 Description Defines the maintenance agreement restrictions. Syntax DellCostofOwnershipString Access Read-only COO Repair Table Table 1268.
Table 1271. COO Repair Index Name cooRepairIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.2 Description Defines the index (one-based) of the repair information for this system. Syntax DellObjectRange Access Read-only Table 1272. COO Repair State Name cooRepairState Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.3 Description Defines the state of the repair information for this system. Syntax DellStateSettings Access Read-only Table 1273.
Description Defines the COO Support Information Table entry. Syntax cooSupportInformationTableEntry Access Not accessible Index cooSupportInformationchassisIndex , cooSupportInformationIndex Table 1277. COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1278.
Syntax DellUnsigned32BitRange Access Read-only Table 1282. COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided. Syntax DellCostofOwnershipString Access Read-only Table 1283. COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1287. COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1288. COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
other(1) The ownership code is not one of following: unknown(2) The ownership code is unknown. owned(3) The ownership code is owned. leased(4) The ownership code is leased. rented(5) The ownership code is rented. offOfLease(6) The ownership code is off of lease. transfer(7) The ownership code is transfer. Table 1292. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown.
Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster, capabilities of the cluster, type of cluster, and name of the cluster. Cluster Table The following table defines the attributes of the cluster. Table 1295. Cluster Table Name clusterTable Object ID 1.3.6.1.4.1.674.10892.1.1800.10 Description Defines the Cluster Table. Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Table 1296. Cluster Table Entry Name clusterTableEntry Object ID 1.3.6.
Syntax DellStateCapabilities Access Read-only Table 1300. Cluster State Settings Name clusterStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.4 Description Defines the state settings of the cluster. Syntax DellStateSettings Access Read-only Table 1301. Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Table 1302. Cluster Type Name clusterType Object ID 1.3.6.
Data Type:Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityC The cluster type is a high-availability cluster. luster(2) Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds.
Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1309. BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.2 Description Defines the index (one-based) of the BMC. Syntax DellObjectRange Access Read-only Table 1310. BMC State Capabilities Name bmcStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.3 Description Defines the state capabilities of the BMC.
Description Defines the description of the BMC. Syntax DisplayString Access Read-only Table 1315. BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only Table 1316. BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
Table 1320. BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.13 Description Defines the IPv6 URL for the BMC. The URL is not present on all systems. Syntax DisplayString Access Read-only Table 1321. BMC Blade Form Factor Name bmcBladeFormFactorName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.14 Description Defines Blade Form Factor Syntax DellBladeFormFactorType Access Read-only Baseboard Management Controller Serial Interface Table 1322.
Table 1325. BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only Table 1326. BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.3 Description Defines the index (one-based) of the BMC serial interface. Syntax DellObjectRange Access Read-only Table 1327.
Table 1331. BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8 Description Defines the connection mode capabilities of the BMC serial interface. Syntax DellBMCSerialConnectionModeCapabilities Access Read-only Table 1332. BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
Index bmcLANInterfaceChassisIndex , bmcLANInterfaceBMCIndex , bmcLANInterfaceIndex Table 1337. BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1338. BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.
Table 1342. BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface. Syntax DellStatus Access Read-only Table 1343. BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface. Syntax DellUnsigned8BitRange Access Read-only Table 1344.
Table 1348. BMC LAN Interface MAC Address Name bmcLANInterfaceMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.12 Description Defines the MAC address of the BMC LAN interface. Syntax DellMACAddress Access Read-only Table 1349. BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13 Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..
modemBasic(1) Modem Basic mode is enabled. modemPPP(2) Modem PPP mode is enabled. modemTerminal(4) Modem Terminal mode is enabled. directBasic(8) Direct Basic mode is enabled. directPPP(16) Direct PPP mode is enabled. directTerminal(32) Direct Terminal mode is enabled. Table 1352. BMC Serial Flow Control Type Variable Name:DellBMCSerialFlowControlType Data Type:Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used.
iDRAC(8) Controller type is iDRAC. iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular). iDRAC6BMC(13) Controller type is Integrated Dell Remote Access Controller 6 (BMC mode). iDRAC7(16) Controller type is Integrated Dell Remote Access Controller 7. iDRAC7Modular(17) Controller type is Integrated Dell Remote Access Controller 7 (Modular).
Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group. Table 1357. Field Replaceable Unit Table Name fruTable Object ID 1.3.6.1.4.1.674.10892.1.2000.10 Description Defines the Field Replaceable Unit table. Syntax SEQUENCE OF FruTableEntry Access Not accessible Table 1358. FRU Table Entry Name fruTableEntry Object ID 1.3.6.1.4.1.
Table 1362. FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.4 Description Defines the state of the FRU information. Some information for the FRU may not be available if the state is other than ok(1). Syntax DellFRUInformationState Access Read-only Table 1363. FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..
Access Read-only Table 1368. FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only Table 1369. FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.11 Description Defines the asset tag of the FRU. Syntax DisplayString (SIZE (0..
3 Storage Management Group The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Table 1373. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1374. Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only Table 1375.
Table 1378. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Table 1379. Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
Table 1383. Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.4 Description Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent. Syntax Integer Access Read-only Table 1384. Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active.
Table 1388. Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1389. Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.10 Description This entry is obsolete. Refer to 0001 softwareVersion. Syntax DisplayString Access Read-only Table 1390. Agent MIB Version Name agentMibVersion Object ID 1.3.6.1.4.1.674.10893.1.
NOTE: This global status should be used by applications other than HP OpenView. HP OpenView should refer to the globalStatus in the root level object group. Syntax DellStatus Access Read-only Table 1393. Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description The previous global status of the system managed by the Storage Management software.
• Fan Connection Table — describes the connection between each fan on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • Power Supply Table — describes available properties for each power supply on the managed system. • Power Supply Connection Table — describes the connection between each power supply on the managed system and its enclosure.
Table 1398. Controller Name Name controllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.2 Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: PERC 3/QC 1. Syntax DisplayString Access Read-only Table 1399. Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name.
Access Read-only Table 1402. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1403. Controller Rebuild Rate In Percent Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1407. Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 Description Identifies the number of physical devices on the controller channel including both disks and the controller. Syntax Integer Access Read-only Table 1408. Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller.
Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB is the total size of the memory. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Table 1413. Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.17 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Access Read-only Table 1418. Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1419. Controller C0 Channel Name controllerC0Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.23 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1420.
Table 1423. Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1424. Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1425.
Syntax Integer Access Read-only Table 1429. Controller Node World Wide Name Name controllerNodeWWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.33 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1430. Controller C0 Port 1 World Wide Name Name controllerC0Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.34 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1434. Controller Component Status Name controllerComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.38 Description Indicates the status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1435.
Access Read-only Table 1438. Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.42 Description Indicates the PCI slot number or embedded number for controllers on the motherboard Syntax DisplayString Access Read-only Table 1439. Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 Description Identifies if the controller is in cluster mode.
Access Read-only Table 1443. Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description The number of channels on the controller. Syntax Integer Access Read-only Table 1444. Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-only Table 1445.
Table 1448. Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode. Possible values: 1: Automatic (enabled) 2: Manual (enabled) 3: Disabled Syntax Integer Access Read-only Table 1449. Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Description The state of the patrol read.
Table 1453. Controller Encryption Capable Name controllerEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.57 Description Indicates encryption capability of the controller. Value: 1 - Capable, 99 - Not Applicable Syntax Integer Access Read-only Table 1454. Controller Encryption Key Persent Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller.
Table 1458. Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Value: 30 to 1440 NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Table 1459. Controller Encryption Mode Name controllerEncryptionMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Access Read-only Table 1463. Controller Configured Drives SpinUp Time Name controllerConfiguredDrivesSpinUpTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 Description Indicates configured drives spin up start time. Value: 1:00 AM to 12:59 PM, 9999 Undetermined Syntax DisplayString Access Read-only Table 1464. Controller Configured Drives SpinUp TimeInterval Name controllerConfiguredDrivesSpinUpTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1467. Controller Current Mode Name controllerCurrentMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.71 Description Indicates the current controller mode. Syntax DisplayString Access Read-only Table 1468. Front Chassis Slot Name frontChassisSlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.72 Description Shows the physical slot on the chassis for stash. Syntax Integer Access Read-only Table 1469. Controller Instance Name controllerInstance Object ID 1.3.6.1.4.1.674.10893.1.
Table 1472. Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry. Syntax ChannelEntry Access Not accessible Index channelNumber Table 1473. Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 Description Identifies the instance number of the channel entry. Syntax Integer Access Read-only Table 1474. Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1477. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel.
Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1481. Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel. Syntax DisplayString Access Read-only Table 1482. Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.
The following object sets up the Enclosure Table. Table 1484. Enclosure Table Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Table 1485. Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry. Syntax EnclosureEntry Access Not accessible Index enclosureNumber Table 1486.
Table 1489. Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.4 Description The current condition of the enclosure (which includes any devices connected to it.) Possible values: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Table 1490. Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management.
Access Read-only Table 1494. Enclosure Asset Tag Name enclosureAssetTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 Description Customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Table 1495. Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Customer definable asset name of the enclosure. Syntax DisplayString Access Read-only Table 1496.
Table 1499. Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1500. Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.15 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1501. Enclosure Type Name enclosureType Object ID 1.3.
1: Joined 2: Split Bus 3: Clustered 4: Unified Syntax Integer Access Read-only Table 1504. Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected. Syntax Integer Access Read-only Table 1505. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Table 1508. Enclosure Roll-Up Status Name enclosureRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.23 Description Identifies the severity of the enclosure state. This is the combined status of the enclosure and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1509. Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Access Read-only Table 1512. Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Table 1513. Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Table 1514. Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.
Table 1517. Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.32 Description Shows the total number of physical slots in a storage enclosure; it includes total count of occupied and empty slots. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Table 1518. Enclosure Empty Slot Count Name enclosureEmptySlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Syntax ArrayDiskEntry Access Not accessible Index arrayDiskNumber Table 1522. Array Disk Number Name arrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1 Description Identifies the instance number of the array disk entry. Syntax Integer Access Read-only Table 1523. Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management.
22: Replacing - Indicates copyback operation is in progress. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 34: Predictive Failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached readonly state.
Syntax DisplayString Access Read-only Table 1530. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Table 1531. Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected.
Access Read-only Table 1535. Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.14 Description The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte. This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk. Syntax Integer Access Read-only Table 1536.
Access Read-only Table 1540. Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.19 Description Identifies the amount in megabytes of the free space on the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Table 1541. Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
5: Not a spare 99: Not applicable Syntax Integer Access Read-only Table 1544. Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.23 Description Severity of the array disk state. This is the combined status of the array disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1545.
Table 1547. Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk. Syntax DisplayString Access Read-only Table 1548. Array Disk Part Number Name arrayDiskPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 Description Indicates the part number of the disk. Syntax DisplayString Access Read-only Table 1549. Array Disk SAS Address Name arrayDiskSASAddress Object ID 1.3.6.1.4.1.
Description Indicates whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert Syntax Integer Access Read-only Table 1553. Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.32 Description Indicates the day of the week (1=Sunday through 7=Saturday) on which this disk was manufactured.
Table 1557. Array Disk Dell Certified Name arrayDiskDellCertified Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.36 Description Indicates if array disk is certified by Dell. Value: 1 - Certified, 0 - Not Certified, 99 Unknown Syntax Integer Access Read-only Table 1558. Array Disk Alta Vendor Id Name arrayDiskAltaVendorId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.37 Description Provides vendor information for Alta interposer. Syntax Octet String Access Read-only Table 1559.
Description Indicates if the physical disk has encryption enabled. Value: 1 - Yes, 0 - No, 99 - Not Applicable Syntax Integer Access Read-only Table 1563. Array Disk Power State Name arrayDiskPowerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.42 Description Indicates power state of a physical drive. Value: 0 - Spun up, 1- Spun down, 255 Transition, 99 - Not Applicable Syntax Integer Access Read-only Table 1564. Array Disk Drive Write Cache Name arrayDiskDriveWriteCache Object ID 1.
Syntax INTEGER Access Read-only Table 1568. Array Disk Device Life Status Name arrayDiskDeviceLifeStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.47 Description Provides PCIe SSD device life status. Possible Values: -1: Not Available / Not Applicable 1: Drive Health Good 2: Approaching Warranty Coverage Expiry 3: Warranty Coverage Expired 4: Approaching Read Only 5: Read Only Syntax INTEGER Access Read-only Table 1569. Array Disk Read Only Name arrayDiskReadOnly Object ID 1.3.6.1.4.1.
Access Read-only Table 1572. Array Disk PI Capable Name arrayDiskPICapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.51 Description Provides the information regarding T10 PI capability of array disk. Possible Values: 0 : T10 PI incapable or 1 : T10 PI capable Syntax INTEGER Access Read-only Table 1573. Array Disk Max Link Width Name arrayDiskMaxLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.52 Description Provides the information regarding Max Link Width of array disk.
Description Displays the current disk write cache policy of the array disk. Possible Values: Enabled - Disabled - Default Syntax DisplayString Access Read-only Table 1577. Array Disk ISE Capable Name arraydiskISECapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.56 Description A boolean value decepting if the disk is Instant Secure Erase Capable or not.
Access Read-only Table 1581. Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.2 Description Identifies the name of the array disk in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1582. Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Table 1586. Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.7 Description Identifies the instance number in the controller, table of the controller to which this array disk is connected. Syntax Integer Access Read-only Array Disk Channel Connection Table This table describes the connections between array disks, their channel, and their associated controller.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Channel Connection Table. Table 1587. Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Table 1588.
Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table. Table 1596. Fan Table Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Table 1597. Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Table 1598.
Access Read-only Table 1601. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1602. Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management.
Table 1605. Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1606. Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.9 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.
Table 1610. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1611. Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components.
Table 1614. Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Fan Connection Table. Table 1615.
Access Read-only Table 1619. Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.3 Description Identifies the instance number of the fan in the fanTable in the connection. Syntax Integer Access Read-only Table 1620. Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this fan belongs.
Access Not accessible Index powerSupplyNumber Table 1624. Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry. Syntax Integer Access Read-only Table 1625. Power Supply Name Name powerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.2 Description Identifies the power supply's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1626.
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1629. Power Supply 1 Part Number Name powerSupply1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.6 Description Identifies the part number of the power supply of the enclosure. Syntax DisplayString Access Read-only Table 1630. Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.
3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1633. Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10 Description Durable unique ID for this power supply. Syntax DisplayString Access Read-only Table 1634. Power Supply Revision Name powerSupplyRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.11 Description Indicates the revision number of the power supply in the enclosure.
Table 1637. Power Supply Connection Number Name powerSupplyConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1 Description Identifies the instance number of the power supply connection entry. Syntax Integer Access Read-only Table 1638. Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in this connection as represented in Storage Management.
Table 1642. Power Supply Connection Firmware Version Name powerSupplyConnectionFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.6 Description Displays power supply connection firmware version. NOTE: Available firmware version 1.04 and later. Syntax DisplayString Access Read-only Temperature Probe Table This table describes available properties for each temperature probe on the managed system. The following object sets up the Temperature Probe Table. Table 1643.
Table 1646. Temperature Probe Name Name temperatureProbeName Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.2 Description Identifies the temperature probe's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1647. Temperature Probe Vendor Name temperatureProbeVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 Description Identifies the temperature probe's (re)seller's name. Syntax DisplayString Access Read-only Table 1648.
Syntax DisplayString Access Read-only Table 1651. Temperature Probe Minimum Warning Name temperatureProbeMinWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.7 Description Identifies the minimum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Table 1652. Temperature Probe Minimum Critical Name temperatureProbeMinCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
Table 1656. Temperature Probe Roll-Up Status Name temperatureProbeRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.12 Description Severity of the temperature probe state. This is the combined status of the temperature probe and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1657. Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.
Table 1659. Temperature Probe Connection Table Name temperatureConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.12 Description Defines the temperature probe connection table. Syntax SEQUENCE OF TemperatureConnectionEntry Access Not accessible Table 1660. Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry.
Table 1664. Temperature Probe Connection Enclosure Name Name temperatureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this temperature probe belongs. Syntax DisplayString Access Read-only Table 1665. Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
Access Read-only Table 1669. Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1670. Enclosure Management Module Vendor Name enclosureManagementModuleVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.3 Description Identifies the enclosure management module's (re)seller's name.
Table 1673. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only Table 1674. Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module.
5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1678. Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 Description The status of the enclosure management module itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1679.
Syntax SEQUENCE OF EnclosureManagementModuleConnectionEntry Access Not accessible Table 1682. Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry. Syntax EnclosureManagementModuleConnectionEntry Access Not accessible Index enclosureManagementModuleConnectionNumber Table 1683.
Access Read-only Table 1687. Enclosure Management Module Connection Enclosure Number Name enclosureManagementModuleConnectionEnclosure Number Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs. Syntax Integer Access Read-only Battery Table This table describes available properties for each controller battery on the managed system.
Syntax DisplayString Access Read-only Table 1692. Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Table 1693. Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.4 Description Identifies the current state of battery.
Table 1695. Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.6 Description The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1696. Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete. Syntax Integer Access Read-only Table 1700. Battery Next Learn Time Name batteryNextLearnTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11 Description Indicates the time (in hours) the next learn cycle must be executed Syntax Integer Access Read-only Table 1701.
Table 1704. Battery Learn Mode Name batteryLearnMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.15 Description Indicates current learn mode of the battery. Possible values: 1: Auto 2: Warn 4: Autowarn 8: Unknown Syntax Integer Access Read-only Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the controller Table.
Table 1708. Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1709. Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
Syntax SEQUENCE OF TapeDriveEntry Access Not accessible Table 1713. Tape Drive Entry Name tapeDriveEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1 Description An entry in the Tape Library table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax TapeDriveEntry Access Not accessible Table 1714. Tape Drive Number Name tapeDriveNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.1 Description Instance number of this tape drive entry.
Table 1718. Tape Drive Nexus ID Name tapeDriveNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.5 Description Durable unique ID for this tape drive Syntax DisplayString Access Read-only Table 1719. Tape Drive Bus Type Name tapeDriveBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6 Description The bus type of the tape drive. Possible values: 8. SAS Syntax INTEGER Access Read-only Table 1720. Tape Drive SAS Address Name tapeDriveSASAddress Object ID 1.3.6.1.4.1.674.10893.1.
Syntax SEQUENCE OF NvmeAdapterEntry Access Not accessible Table 1723. NVME Adapter Entry Name nvmeAdapterEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1 Description An entry in the NvmeAdapter table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax NvmeAdapterEntry Access Not accessible Table 1724. NVME Adapter Number Name nvmeAdapterNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.
Table 1728. NVME Adapter Device Name Name nvmeAdapterDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.5 Description The device name of the NVMe Adapter as it is represented in OMSA and also the operating system. Syntax DisplayString Access Read-only Table 1729. NVME Adapter Vendor Name nvmeAdapterVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.6 Description NVMe Adapter manufacturer. Syntax DisplayString Access Read-only Table 1730.
Description NVMe Adapter driver version. Syntax DisplayString Access Read-only Table 1734. NVME Adapter PCI Bus Number Name nvmeAdapterPCIBusNo Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.11 Description The PCI Bus number of the NVMe adapter. Syntax INTEGER Access Read-only Table 1735. NVME Adapter PCI Device Number Name nvmeAdapterPCIDeviceNum Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.12 Description The PCI device number of the NVMe Adapter.
Table 1739. NVME Adapter Media Type Name nvmeAdapterMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.16 Description NVMe Adapter media type. Possible Values: 1: unknown 2: ssd Syntax INTEGER Access Read-only Table 1740. NVME Adapter Length In Mega Bytes Name nvmeAdapterLengthInMegaBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.17 Description Size in megabytes of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1741.
Table 1744. NVME Adapter Negotiated Speed Name nvmeAdapterNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.21 Description The negotiated speed of the NVMe adapter in GT/s. Syntax DisplayString Access Read-only Table 1745. NVME Adapter Capable Speed Name nvmeAdapterCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.22 Description The maximum rated speed of the NVMe adapter in GT/s. Syntax INTEGER Access Read-only Table 1746.
Description The maximum bus width of NVME Adapter. Syntax INTEGER Access Read-only Table 1750. NVME Adapter Negotiated Link Width Name nvmeAdapterNegotiatedLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.27 Description The negotiated bus width of NVMe Adapter. Syntax INTEGER Access Read-only Table 1751. NVME Adapter Sub Vendor Name nvmeAdapterSubVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.28 Description Sub vendor of the NVMe Adapter device.
Table 1753. Virtual Disk Table Name virtualDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1 Description Defines the virtual disk table. Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Table 1754. Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Table 1755. Virtual Disk Number Name virtualDiskNumber Object ID 1.
Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable. 6: Degraded - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online.
Syntax INTEGER Access Read-only Table 1762. Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1763. Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete.
5: LSI No Read Ahead 9: Not Applicable Syntax INTEGER Access Read-only Table 1766. Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax INTEGER Access Read-only Table 1767. Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.
Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1771. Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 Description Unique ID for the virtual disk. Syntax INTEGER Access Read-only Table 1772. Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete.
3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1775. Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Table 1776. Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Access Read-only Table 1779. Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 Description Indicates if this virtual disk is configured as CacheCade. Value: 1 - Yes, 0 - No, 99 - Undetermined Syntax INTEGER Access Read-only Table 1780. Virtual Disk Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26 Description Indicates disk cache policy of the logical device.
Table 1783. Virtual Disk Partition Entry Name virtualDiskPartitionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1 Description An entry in the Virtual Disk Partition table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax VirtualDiskPartitionEntry Access Not—Accessible Table 1784. Virtual Disk Partition Number Name virtualDiskPartitionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.
Table 1788. Virtual Disk Partition Nexus ID Name virtualDiskPartitionNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.6 Description Durable unique ID for this partition. This comprises the controllerID, virtualDisk ID and hash mapped WWN number of this partition. Syntax DisplayString Access Read-only Array Disk Logical Connection Table This table describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk.
Access Read-only Table 1793. Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.3 Description Identifies the instance number of the array disk in this logical connection. Syntax Integer Access Read-only Table 1794. Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Storage Management Event Group The Storage Management Event Group defines the properties that are sent with SNMP traps. Table 1798. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management event message number. Syntax Integer Access Read-only Table 1799. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert.
Table 1803. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1804. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1805. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.
Syntax DisplayString Access Read-only Table 1809. Chassis Service Tag Event Name chassisServiceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.12 Description Chassis Service Tag of object causing the alert if applicable.
4 Change Management Group The Change Management Group lets you monitor information about the devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM package must be installed for Dell EMC OpenManage Server Administrator to respond to SNMP queries in this group. See the Dell EMC Server Administrator Installation Guide for more information.
Table 1813. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1814. Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Table 1815. Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.1 Description Defines the unique index for this device.
Table 1819. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Table 1820. Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Table 1821. Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Access Read-only Table 1824. Application Index Name aplicationIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.1 Description Defines the unique index for this application. Syntax Unsigned16BitRange Access Read-only Table 1825. Application Device Index Name applicationDeviceIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.2 Description Defines a cross-index to the device table for the application. Syntax Unsigned16BitRange Access Read-only Table 1826.
Access Read-only Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Inventory Collector Product Information The following objects describe the fields for the Inventory Collector.
5 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Table 1832. Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.3 Description Describes the alert. Syntax DisplayString Table 1833. Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.
Syntax DisplayString Table 1838. Service Tag Variable Name alertServiceTag Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9 Description Specifies the system service tag of the system generating the alert. Syntax DisplayString Table 1839. Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.4.5000.10.10 Description Specifies the chassis service tag of the system generating the alert.
Description Line Item Explanation Date and time of action: Fri May 30 23:55:44 2003. Description: Specifies the description of the event that occurred, for example: Description: Chipset Err: Critical Event sensor, front panel NMI / diagnostic interrupt was asserted.
Description Line Item Explanation SD card device type: Specifies the type of SD card device, for example: SD card device type: Hypervisor SD card state: Specifies the state of the SD card, for example: SD card state: Present, Failed Sensor location: Specifies the location of the sensor in the specified chassis, for example: Sensor location: CPU1 Temperature sensor value (in degrees Celsius): Specifies the temperature in deg
TrapID Description Severity 65799 Over-Temperature warning (Upper noncritical, going high) Minor 65927 Over-Temperature warning Cleared Information 65801 Over-Temperature Problem (Upper Critical Critical - going high) 65929 Over-Temperature Problem Cleared Information 131328 Under-Voltage Warning (Lower Non Critical - going low) Warning 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical going low) Critical 131458 Under-Voltage Problem Cleare
TrapID Description Severity 487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Information 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Information 487175 CPU Presence (Processor Presence detected) Information 487303 CPU Not Present (Processor Not Present) Critical 487170 CPU BIST (Built In Self Test) Failure Critical 487298 CPU BIST (Built In Self Test) Failur
TrapID Description Severity 2322177 ASR (Automatic System Recovery) Reset Occurred Critical 2322178 ASR (Automatic System Recovery) Power Critical Down Occurred 2322179 ASR (Automatic System Recovery) Power Critical Cycle Occurred 422
6 Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Warning/Non-critical alert may indicate that a component (such as a temperature probe in an enclosure) has crossed a warning threshold. Critical/Failure/Error A component has either failed or failure is imminent. This alert indicates a serious problem such as data loss or a loss of function. For example, a Critical/Failure/Error alert may indicate that an array disk has failed. SNMP Support for Storage Management Alerts By default, Storage Management installs SNMP trap forwarding support.
Description Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Table 1845. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Table 1846. Object Name Event Name objectNameEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Table 1850. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable. Syntax DellStatus Access Read-only The following table shows the new enhanced mode varbinds which would be available in the EEMI where the user can get both Traditional and Enhanced varbinds : Table 1851. Enhanced Message ID Event Name enhancedMessageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Descriptions and Corrective Actions section. For more information on the MIB and its structure, as well as a change history of the SNMP traps, see the Introduction section. For more information on configuring SNMP, see Support for Storage Management Alerts .
7 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
enableAndNotReadyCapable (6) Enable and not ready capable. Table 1857. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown. enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The object is not ready.
Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant. degraded(4) The object’s redundancy has been degraded. lost(5) The object’s redundancy has been lost. notRedundant(6) Redundancy does not apply or it is not redundant. Table 1861.
8 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
1.3.6.1.4.1.674.10892.1.200.10.1.28.1 = '\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03' 1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.300.