CLI Guide

Table 66. Valid Parameters Of Events for Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=systempeakpower Sets actions when a power consumption probe detects peak power value.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.
event=powersupply Sets actions when a power supply probe detects a failure value.
event=powersupplywarn Sets actions when a power supply probe detects a warning value.
event=processorwarn Sets actions when a processor probe detects a warning value.
event=processorfail Sets actions when a processor probe detects a failure value.
event=redundegrad Sets actions when a redundant component becomes inoperative, resulting in less than full
redundancy for that component.
event=redunlost Sets actions when one or more redundant components become inoperative, resulting in a lost or
a "no redundant components working" condition for that component.
event=tempwarn Sets actions when a temperature probe detects a warning value.
event=tempfail Sets actions when a temperature probe detects a failure value.
event=voltwarn Sets actions when a voltage probe detects a warning value.
event=voltfail Sets actions when a voltage probe detects a failure value.
event=watchdogasr Sets actions that Server Administrator performs on the next system startup after a watchdog
Automatic System Recovery (ASR) is performed for a hung operating system.
event=removableashmediaprese
nt
Sets actions that Server Administrator performs when the system detects a removable ash
media.
event=removableashmediaremo
ved
Sets actions that Server Administrator performs when a removable ash media is removed.
event=removableashmediafail Sets actions that Server Administrator performs when a removable ash media fails.
event=storagesyswarn Sets actions when a storage system detects a warning value.
event=storagesysfail Sets actions when a storage system detects a failure value.
event=storagectrlwarn Sets actions when a storage controller detects a warning value.
event=storagectrlfail Sets actions when a storage controller detects a failure value.
event=pdiskwarn Sets actions when a physical disk detects a warning value.
98