CLI Guide
name=value pair 1
cong=
name=value pair 2 Description
subnet=Subnet Sets a subnet mask if you have selected static as the IP
address source for the BMC LAN interface.
gateway=Gateway
Sets a gateway address if you have selected static as the IP
address source for the BMC LAN interface.
ipsource=static | dhcp | systemsoftware
static: Static if the IP address of the BMC LAN interface is
a xed, assigned IP address.
dhcp: DHCP if the source of the IP address of the BMC
LAN interface is the dynamic host conguration protocol.
systemsoftware: System software if the source of the IP
address of the BMC LAN interface is from the system
software.
NOTE: All commands may not be supported on the
system.
ipaddressv6=<IPv6 address>
prexlength= length
Validates the IPv6 address for conguration.
gatewayv6=<value> Validates the IPv6 gateway.
ipsourcev6=static | auto
static: IPv6 address source is set to static.
auto: IPv6 address source is set to auto.
altdnsserverv6 Validates the address of the alternate DNS server for
conguration.
dnssourcev6=static | auto
static: DNS source is set to static.
auto: DNS source is set to auto.
vlanenable=true | false
true: Enables the virtual LAN identication.
false: Disables the virtual LAN identication.
vlanid=number
number: Virtual LAN identication in the range of 1 to 4094.
vlanpriority=number
number: Priority of virtual LAN identication in the range of
0 to 7.
privilegelevel=administrator | operator |
user
administrator: Sets the maximum privilege level that is
accepted on a LAN channel, to Administrator.
operator: Sets the maximum privilege level that is accepted
on a LAN channel, to Operator.
user: Sets the maximum privilege level that is accepted on
a LAN channel, to User.
encryptkey=text conrmencryptkey=text text: Text used for encryption and conrmation of
encryption.
prefdnsserverv6=<value> Validates the preferred DNS server for conguration.
cong=serial
baudrate=9600 | 19200 | 38400 | 57600
| 115200
9600: Sets the connection speed to 9600 bits per second.
19200: Sets the connection speed to 19200 bits per
second.
38400: Sets the volatile and non-volatile connection speed
to 38400 bits per second.
57600: Sets the volatile and non-volatile connection speed
to 57600 bits per second.
115200: Sets the volatile and non-volatile connection speed
to 115200 bits per second.
owcontrol=none | rtscts
none: No control over the ow of communication through
the serial port.
rtscts: RTS is ready to send and CTS is clear to send.
80