CLI Guide
name=value pair 1 name=value pair 2 Description
NOTE: These options are applicable
only when a custom prole is
selected.
NOTE: Reboot the system for the power proles setup options to take eect.
Omcong Chassis Pwrmonitoring Or Omcong Mainsystem Pwrmonitoring
Use the omcong chassis pwrmonitoring or omcong mainsystem pwrmonitoring command to congure power consumption
information.
The following table displays the valid parameters for the command:
Table 53. Valid Parameters Of Omcong Chassis Pwrmonitoring Or Omcong Mainsystem Pwrmonitoring
name=value pair 1 name=value pair 2 Description
index=<n> NA Number of the probe or probe index (must
specify).
cong=probe warnthresh=settodefault Sets the minimum and maximum warning
thresholds values to default.
warnthresh=<n > Sets a value for the warning threshold.
unit=watt | btuphr
watt: Displays the unit in Watts.
btuphr: Displays the unit in BTU/hr.
cong=resetreading type=energy | peakpower
energy: Resets the system energy
reading.
peakpower: Resets the system peak
power.
NOTE: This command is applicable only on selected Dell 10G systems that support PMBus.
NOTE: Power monitoring requires license to congure the power budget information. If the appropriate license is not
installed or has expired, the system displays an error message. For more information, see
Dell License Manager
at
dell.com/openmanagemanuals.
Default warning thresholds
NOTE: Sensor managing capabilities vary across systems.
To set both the upper and lower power consumption probe warning threshold values to the recommended default value, type:
omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefault
or
omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum warning threshold value, you are also selecting the default
value for the maximum warning threshold value.
Specify A Value For Warning Thresholds
If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the probe you
are conguring and the warning threshold value. Congure the values to display either in BTU/hr or Watts. In the following example,
the probe that is being congured is probe 4:
omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt
or
omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325 unit=btuphr
77