CLI Guide
Command
Level 1
Command Level 2 Command Level 3 User
Privilege
Required
Use
webserver A Starts or stops the Web server.
chassis or
mainsystem
biossetup A Congures the behavior of specic system components
controlled by the BIOS.
fans P, A
Congures fan probe warning thresholds to the default or a
specic value.
NOTE: You cannot change threshold values on
embedded server management (ESM3) and Dell
PowerEdge
x8xx
systems.
frontpanel A Congures the Power button, Non-Masking Interrupt (NMI)
button, encryption access, and LCD display of the system.
info P, A Allows you to set an initial value, or to edit the value of the
asset tag or chassis name.
leds P, A Species when to ash a chassis fault LED or chassis
identication LED, and allows you to clear the LED for the
system's hard drive.
memorymode A Enables or disables the spare bank, mirroring, raid, and
Double Device Data Correction (DDDC) memory modes, and
also specify which mode to use.
pwrmanagement P, A Allows you to choose between maximum power, economy,
and optimized performance of the system.
pwrmonitoring P, A Congures power consumption information and thresholds.
remoteaccess A Congures remote access information.
temps P, A
Sets warning threshold values to the default or a specic
value.
NOTE: You cannot change threshold values on ESM3
and PowerEdge
x8xx
systems.
volts P, A
Sets warning threshold values to the default or a specic
value.
NOTE: You cannot change threshold values on ESM3
and PowerEdge
x8xx
systems.
storage For more information, see Using The Storage Management
Service.
Help With The Omcong Command
The following table lists the usage of omcong commands.
53