CLI Guide

NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server
Administrator displays the USC version.
Depending on the system’s conguration, you may notice the following output:
Table 15. System conguration output
Index : 0
Chassis Name : Main System Chassis
Host Name : WIN-27C02UQFV6L
iDRAC7 Version : 1.00
Chassis Model : PowerEdge R720
Chassis Lock : Present
Chassis Service Tag : 7654321
Express Service Code : 15608862073
Chassis Asset Tag : c
Omreport Chassis Intrusion
Use the omreport chassis intrusion command to nd out whether the cover of the system is open or not. Server Administrator
tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component, or to perform unauthorized
maintenance on the system. Type:
omreport chassis intrusion
A message that resembles the following is displayed:
Table 16. Output
Intrusion Information
Health : Ok
Index : 0
Status : OK
Probe Name : Intrusion
State : Chassis is closed
Omreport Chassis Leds Or Omreport Mainsystem Leds
Use the omreport chassis leds or omreport mainsystem leds command to nd out whether clear hard drive fault is supported and
what severity level lights up the LED. Type:
omreport chassis leds index=n
or
omreport mainsystem leds index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of LED information for
chassis 0. If you specify the index, Server Administrator displays a summary for a specic chassis.
The following is an example output:
Table 17. Output
Main System Chassis
Flash chassis identify LED state : Off
Flash chassis identify LED timeout value : 300
26