CLI Guide
Chassis management
On servers with Dell PowerEdge FX2 series chassis, when Chassis Management at Server Mode is set to Monitor or Manage and
Monitor in CMC, OMSA displays Chassis Management at Server Mode as Enabled and displays the Fans, Power Supplies, and
Temperature sensor details. The sensor details are read-only. When Chassis Management at Server Mode is set to None in CMC,
OMSA displays Chassis Management at Server Mode as Disabled and displays only the server temperature sensors (not chassis
temperature sensors).
Related Links
• omreport chassis fans or omreport mainsystem fans
• omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
• omreport chassis temps or omreport mainsystem temps
Omreport chassis acswitch or omreport mainsystem acswitch
Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that
are congured in a failover arrangement. Type:
omreport chassis acswitch
or
omreport mainsystem acswitch
Server Administrator displays the following output:
Table 12. Server administrator output
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required for
full redundancy
: 2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1, upon redundancy restoration,
return to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active
Server Administrator reports values for the Redundancy Status and Redundancy Mode elds.
Omreport Chassis Batteries Or Omreport Mainsystem Batteries
Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties. Type:
omreport chassis batteries
22