CLI Guide
Omcong Global Commands
The following table displays the omcong command syntax required to execute the global commands. When executed, these
commands apply to all controllers. These global commands also correspond to the global tasks provided by the Storage tree view
object’s Information/Conguration subtab.
Table 209. Omcong Global Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs
omcong storage globalinfo
action=enablests
action=disablests
action=globalrescan
action=setprotectionpolicies type=ghs or dhs
action=setremainingratedwriteendurancethreshold type=sassata | pcie threshold=<1-100>
Omcong Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0
or 50 degree Celsius. However, if you have implemented connector redundancy on the PV220S and PV221S enclosures you can
specify that only the enclosure and not the operating system and server are shut down when the enclosure reaches a critical
temperature of 0 or 50 degree Celsius. Specifying that only the enclosure is shut down during excessive temperatures is known as
Smart Thermal Shutdown. For more information about Smart Thermal Shutdown, see the
Dell EMC OpenManage Online Help.
Table 210. Omcong Global Enable Smart Thermal Shutdown
Description Enables smart thermal shutdown.
Syntax
omconfig storage globalinfo action=enablests
Example to Enable thermal shutdown. The omcong command syntax for enabling thermal shutdown does not
require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to determine whether smart
thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is
also displayed by the Server Administrator graphical user interface (GUI). To locate this
status, select the Storage object and the Information/Conguration tab.
Example
omconfig storage globalinfo action=enablests
Omcong Global Disable Smart Thermal Shutdown
If you have previously enabled smart thermal shutdown using the omcong command, you can disable smart thermal shutdown and
return the system to its default setting. When smart thermal shutdown is disabled, the operating system and the server shuts down
when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius.
Table 211. Omcong Global Disable Smart Thermal Shutdown
Description Disables smart thermal shutdown for all controllers.
Syntax
omconfig storage globalinfo action=disablests
Example to Disable thermal shutdown. The omcong command syntax for disabling thermal shutdown does not
require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to determine whether smart
thermal shutdown is currently enabled or disabled. The status of smart thermal shutdown is
also displayed in the GUI of Server Administrator. To locate this status, select the Storage
object and the Information/Conguration tab.
Example
omconfig storage globalinfo action=disablests
163