CLI Guide
Required Command Levels (1, 2,
3)
Optional name=value pairs
action=setpdiskpwrmanagement controller=id spindownuncongureddrives=<enabled/
disabled> spindownhotspares=<enabled/disabled> spindowncongureddrives=<enabled/
disabled> idlec=<enabled/disabled> spindowntimeinterval=<30 to 1440>(minutes)
spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval=<1 to 24>(hours)
NOTE: Specify spinupstarttime and spinuptimeinterval only when you set
spindowncongureddrives=enabled.
action=setcontrollermode controller=id mode=<raid | hba>
action=autocongureRAID0 controller=id
action=setpatrolreadmode controller=id mode=<manual | auto | disable>
action=startpatrolread controller=id
action=stoppatrolread controller=id
action=createcachecade controller=id pdisk=<PDISKID> [name=<string>]
action=enablelkm controller=id keyid=<keyid> passphrase=<passphrase string> [escrow=yes]
[lepath=<Absolute path to the escrow le>]
NOTE: If you set escrow=yes, specify the escrow le path.
action=switchtolkm controller=id keyid=<keyid> passphrase=<passphrase string>
[escrow=yes] [lepath=<Absolute path to the escrow le>]
NOTE: If you set escrow=yes, specify the escrow le path.
action=rekeylkm controller=id
action=convertraidtononraid controller=id pdisk=<PDISKID>
action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Omcong Rescan Controller
Table 152. Omcong Rescan Controller
Description Rescans a controller. For more information, see the Dell EMC OpenManage Online Help .
Syntax omconfig storage controller action=rescan controller=id, where id is the
controller ID as reported by the omreport storage controller command.
Example to Rescan controller 1.
Example
omconfig storage controller action=rescan controller=1
NOTE: The rescan controller is not supported on non-RAID SCSI and SAS controllers.
Reboot the system to make the conguration changes visible on non-RAID SCSI
controllers.
Omcong Enable Controller Alarm
Table 153. Omcong Enable Controller Alarm
Description Enables the controller alarm. For more information, see the Dell EMC OpenManage Online Help .
Syntax omconfig storage controller action=enablealarm controller=id, where id is
the controller ID as reported by the omreport storage controller command.
Example to Enable the alarm on controller 1.
145