CLI Guide
Event Name Description
event=processorfail Sets action or enables or disables alert generation when a processor probe detects that
the processor has failed.
event=processorabsent Sets action or enables or disables alert generation when a processor probe detects that
the processor is absent.
event=redundegrad Sets action or enables or disables alert generation when the system fans and/or power
supplies become inoperative, resulting in less than full redundancy for that component.
event=redunlost Sets action or enables or disables alert generation when the system fans and/or power
supplies become inoperative, resulting in a lost or a no redundant components working
condition for that component.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.
event=tempwarn Sets action or enables or disables alert generation when a temperature probe detects
that the temperature is approaching the maximum high or low limits.
event=removableashmediapresent Sets actions that Server Administrator performs when the system detects a removable
ash media.
event=removableashmediawarn Sets actions that Server Administrator performs when a removable ash media warning
is displayed.
event=removableashmediafail Sets actions that Server Administrator performs when a removable ash media fails.
event=tempfail Sets action or enables or disables alert generation when a temperature probe detects
that the temperature is either too high or low for proper operation.
event=voltfail Sets action or enables or disables alert generation when a voltage probe detects that the
voltage is too low for proper operation.
event=intdualsdcardcritical Sets actions that Server Administrator performs when an internal dual SD card critical
event occurs.
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card warning is
displayed.
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not
available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual
SD card is lost.
event=watchdogasr Enables or disables alert generation congured by the ASR when the system has hung or
is not responding.
Omcong system snmptraptest or omcong servermodule snmptraptest
Use the omcong system snmptraptest or omcong servermodule snmptraptest command to send the snmp test trap to the
destination address if Server Administrator SNMP component is congured in the conguration le.
The following table displays the valid parameters for the command:
Table 70. Parameters For Alert Action Command
Action Description
dest=<ipv4 address |
ipv6 address | fqdn>
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMware ESXi.
102