CLI Guide
Table 68. Parameters For Alert Action Command
Action Description
action=disable Disables the SNMP alert.
action=enable Enables the SNMP alert.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns o the electrical power to the system, pauses, turns on the power, and reboots the system.
action=powero Turns o the electrical power to the system.
action=powerreduction Reduces the processor speed until the power consumption comes down and reaches below the
warning threshold. If the system power consumption remains below the warning threshold, increase the
processor speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems earlier than 11th
generation of PowerEdge systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs BIOS checks, and
reloads the operating system.
Components and events of platform events
The following table lists the components and the events for which you can set platform events. Components are listed in
alphabetical order, except that warning events always precede failure events for a component.
Table 69. Valid Parameters Of Omcong System Platformevents
Event Name Description
alertsenable=true | false
true: Enables generation of platform event lter alerts.
false: Disables generation of platform event lter alerts.
NOTE: This setting is independent of the individual platform event lter alert
settings. For a platform event lter to generate an alert, both the individual alert
and the global event alert are enabled.
event=batterywarn Sets action or enables or disables alert generation when a battery device detects that the
battery is pending a failure condition.
event=batteryfail Sets action or enables or disables alert generation when a battery device detects that the
battery has failed.
event=discretevolt Sets action or enables or disables alert generation when a discrete voltage probe detects
that the voltage is too low for proper operation.
event=fanfail Sets action or enables or disables alert generation when a fan probe detects that the fan
is running too slow or not at all.
event=hardwarelogfail Enables or disables alert generation when a hardware log detects a failure value.
event=intrusion Sets action or enables or disables alert generation when a chassis is opened.
event=powerwarn Sets action or enables or disables alert generation when a power device probe detects
that the power supply, voltage regulator module, or DC to DC converter is pending a
failure condition.
event=powerabsent Sets action or enables or disables alert generation when a processor probe detects that
the power supply is absent.
event=powerfail Sets action or enables or disables alert generation when a power device probe detects
that the power supply, voltage regulator module, or DC to DC converter has failed.
event=processorwarn Sets action or enables or disables alert generation when a processor probe detects that
the processor is running at less than peak performance or speed.
101