Users Guide
Property Denition
The bus conguration switch when toggled on a 220S or 221S enclosure,
the enclosure should be turned o. For more information, see Changing The
Mode On 220S And 221S Enclosures.
Older 200S enclosures with a version 1.8 kernel that only have one EMM
may display Split Bus mode and not Joined Bus mode. Joined Bus or
Clustered modes may display when applicable in these circumstances.
Firmware Version Displays the version of the enclosure rmware.
NOTE: For systems supporting multiple backplanes, the rmware
version appears as upstream and downstream versions.
Service Tag Displays the enclosure Service Tag. The enclosure is identied by a unique
Service Tag number. This information is used to route support calls to the
appropriate personnel.
Express Service Code The enclosure is identied by a unique Express Service Code number. This
information is used to route support calls to the appropriate personnel.
Asset Tag Displays the asset tag information for the enclosure. You can change this
property using the Setting Asset Data task.
Asset Name Displays the name assigned to the enclosure. You can change this property
using the Setting Asset Data task.
Backplane Part Number Displays the part number of the enclosure backplane.
SAS Address Displays the SAS address of the SAS backplane.
Split Bus Part Number Displays the part number of the enclosure split bus module. A split bus is
indicated by a single triangle symbol on the back of the enclosure.
Enclosure Part Number Displays the part number of the enclosure.
Enclosure Alarm Displays whether the alarm on the enclosure is enabled or disabled.
Enclosure And Backplane Tasks
To execute a drop-down menu enclosure task:
1. In the Server Administrator window, under the system tree, expand Storage dashboard to display the controller objects.
2. Expand a controller object.
3. Select the Enclosure object.
4. Click Information/Conguration on the storage Properties screen.
5. Select a task from the Enclosure Tasks drop-down menu.
6. Click Execute.
Enclosure — Available Tasks
The drop-down menu enclosure tasks are:
• Enabling The Enclosure Alarm
• Disabling The Enclosure Alarm
• Setting Asset Data
• Blinking The LED On The Enclosure
• Setting The Temperature Probe Values
Enabling The Enclosure Alarm
Does my enclosure support this feature? See Supported Features.
Select the Enable Alarm task to enable the enclosure alarm. When enabled, the alarm turns on when any of the following events
occur:
94