Users Guide
To Launch The Set Temperature Probe Wizard
To launch the Set Temperature Probe wizard:
1. In the Server Administrator window, under the system tree, expand Storage to display the controller objects.
2. Expand a controller object.
3. Expand the enclosure object.
4. Select the Temperatures object.
5. Click Set Temperature Probe.
Temperature Probe Properties And Tasks
Does my enclosure support this feature? See Supported Features. Use this window to view information about the enclosure’s
temperature probes.
Table 24. Temperature Probe Properties
Property Denition
Status These icons represent the severity or health of the storage
component.
— Normal/OK
— Warning/Non-critical
— Critical/Failure/Error
For more information, see Storage Component Severity.
NOTE: On some enclosures, Storage Management may
experience a short delay before displaying the current
enclosure temperature and temperature probe status.
For more information, see Storage Management May
Delay Before Updating Temperature Probe Status.
Name Displays the name of the temperature probe.
State Displays the status of the temperature probe.
• Ready — The temperature probe is functioning normally.
• Degraded — The temperature probe has encountered a
failure and is operating in a degraded state.
• Failed — The temperature probe has encountered a failure
and is no longer functioning. Storage Management is unable
to communicate with the enclosure using SES commands.
The Failed state is displayed when the enclosure does not
respond to a status query from Storage Management for
any reason. For example, disconnecting the cable causes a
Failed state.
• Minimum Warning Threshold Exceeded — The
temperature of the enclosure has dropped below the
minimum warning threshold.
• Maximum Warning Threshold Exceeded — The
temperature of the enclosure has exceeded above the
maximum warning threshold.
• Missing — The temperature probe is not present in the
enclosure.
• Inactive — The temperature probe is present in the
enclosure, but the EMM that it monitors is not installed.
Reading Displays the current temperature of the enclosure as reported
by the temperature probe.
Warning Threshold The Minimum and Maximum properties indicate the
temperatures currently set for the Warning threshold.
90