Users Guide

Virtual Disk Specication PERC S140
Maximum Stripe Size 64 K
Maximum Number of Virtual Disks per Physical Disk 8
Maximum Number of Physical Disks that Can Be
Concatenated
NA
Maximum Number of Physical Disks in a RAID 0 8
Maximum Physical Disks in a RAID 1 2
Maximum Number of Physical Disks in a RAID 5 8
Maximum Number of Physical Disks in a RAID 10 4
Minimum Number of Physical Disks that Can Be
Concatenated
NA
Minimum Number of Physical Disks in a RAID 0 2
Minimum Number of Physical Disks in a RAID 1 2
Minimum Number of Physical Disks in a RAID 5 3
Minimum Number of Physical Disks in a RAID 10 4
NOTE: When creating virtual disks using software RAID controllers, the information related to the member physical disks
of the virtual disk is enumerated or displayed on Storage Management after a short delay. This delay in displaying the
information does not cause any functional limitation. If you are creating partial virtual disks, it is recommended that you
provide Storage Management adequate time between each partial virtual disk creation process.
RAID Levels Supported By The PERC S140 Controller
Table 50. RAID Levels Supported by the PERC S140 Controller
RAID Level PERC S140
RAID 0 Yes
RAID 1 Yes
RAID 5 Yes
RAID 10 Yes
RAID 50 No
RAID 6 No
RAID 60 No
Supported Features On The Non-RAID Controllers
This section identies the controller-supported features and whether an enclosure can be attached to the controller.
Controller Tasks
Battery Tasks
Connector Tasks
Physical Disk Tasks
Virtual Disk Tasks
169