Reference Guide

0 - Unknown
1 - Single
2 - Dual
4 - Quad
8 - Octal
16 - Hexa
SpeedAsString Indicates the accurate speed of
the physical memory, in string
format (with units).
string
Capacity Indicates the total capacity of
this physical memory, in bytes.
uint64
BankLabel A string identifying the
physically labeled bank where
the memory is located, for
example, "Bank 0" or "Bank A."
string
PositionInRow Species the position of the
physical memory in a “row.” For
example, if it takes two 8-bit
memory devices to form a 16-
bit row, then a value of 2
means that this memory is the
second device. 0 is an invalid
value for this property.
uint32
InterleavePosition Indicates the position of this
physical memory in an
interleave. 0 indicates
noninterleaved. 1 indicates the
rst position, 2 the second
position, and so on. For
example, in a 2:1 interleave, a
value of 1 indicates that the
memory is in the “even
position.
uint32
Manufacturer Indicates the manufacturer of
the physical memory.
string
SerialNumber Indicates the serial number of
the physical memory.
string
CIM_PhysicalConnector
The CIM_PhysicalConnector class listed in Physical Connector Properties includes physical elements such as plugs, jacks, or buses
that connect physical elements. Any object that can be used to connect and transmit signals or power between two or more physical
elements is a member of this class. For example, slots and D-shell connectors are types of physical connectors. See Connector Type
Values for a list of valid connector type values.
Table 11. CIM_PhysicalConnector Properties
Class Name: CIM_PhysicalConnector
Parent Class: CIM_PhysicalElement
Property Description Data Type
18