SNMP Reference Guide for iDRAC and Chassis Management Controller
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction................................................................................................................................. 5 What is new in this release................................................................................................................................................... 5 Supported SNMP Versions..................................................................................................................................................
System Information Group........................................................................................................................................... 46 Status Group.................................................................................................................................................................. 49 Systems Details Group..................................................................................................................................................
1 Introduction This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC and Chassis Management Controller. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
Table 2. Managed Object Used in This Document MIB Name Agent / Hardware Supported Purpose of the MIB 10892.mib Server Administrator Provides the information about the systems monitored by Server Administrator instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.mib Server Administrator Provides the information about the system Field Replaceable Unit (FRU) to SNMP management applications. dcstorag.
Table 3. Server Administrator Remote Access MIB Sections in This Guide Topic MIB Group Numbers Remote Access Group — provides information about remote access hardware that may be present in your system and defines variables for administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations 1700 Dell Remote Access Controller Out-of-Band MIB The Dell Remote Access Controller Out-of-Band MIB (filename DELL-RAC-MIB.
Status refers to the health of an object or how the object is functioning. For example, the status of a temperature probe that is measuring acceptable temperatures would be reported as normal. When the probe begins reading temperatures that exceed limits set by the user, it reports a critical status. Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects.
Syntax DellObjectRange Access Read-only Table 9. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 10. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis.
2 Chassis Management Controller Group Table 11. Chassis Management Controller Group Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting.
Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only Table 16. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 17. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis.
Table 22. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 23. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only Table 24. DRsProductSystemSlot Name drsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Syntax DellString Access Read-only Table 29. DRsProductChassisRackSlot Name drsProductChassisRackSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.18 Description Defines the rack slot locator of the chassis. Syntax DellString Access Read-only Table 30. DRsProductChassisModel Name drsProductChassisModel Object ID 1.3.6.1.4.1.674.10892.2.1.1.19 Description Defines the model of the chassis. Syntax DellString Access Read-only Table 31.
Table 35. DRsiKVMFirmwareVersion Name drsiKVMFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.2 Description Defines the firmware version of the iKVM. Syntax DellString Access Read-only Table 36. DRsFirmwareVersion2 Name drsFirmwareVersion2 Object ID 1.3.6.1.4.1.674.10892.2.1.2.3 Description Defines the firmware version of chassis management controller 2.
Table 41. DRsRedCurrStatus Name drsRedCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.4 Description Defines the redundancy status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 42. DRsPowerCurrStatus Name drsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 43.
Description Defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. Syntax DellTemperatureReading Access Read-only Table 48. DRsCMCAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only Table 49.
Access Read-only Table 54. DRsPowerPrevStatus Name drsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 55. DRsFanPrevStatus Name drsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 56.
Object ID 1.3.6.1.4.1.674.10892.2.3.3.2 Description Defines the timestamp of the most recent IOM status change. Syntax TimeTicks Access Read-only Table 61. DRsKVMChangeTime Name drsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only Table 62. DRsRedChangeTime Name drsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.
Table 67. DRsCMCChangeTime Name drsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change. Syntax TimeTicks Access Read-only Chassis Power The following MIB tables provide power information for the chassis being monitored by the chassis management controller. Table 68. DRsCMC Power Table Name drsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table.
Syntax DellCMCPowerIndexRange Access Read-only Table 73. DRsPotentialPower Name drsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2 Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only Table 74. DRsIdlePower Name drsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Table 79. DRsWattsPeakUsage Name drsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in watts) since last reset. Syntax DellPowerReading Access Read-only Table 80. DRsWattsPeakTime Name drsWattsPeakTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9 Description Defines the timestamp of the most recent chassis peak power usage. Syntax DellTimestamp Access Read-only Table 81. DRsWattsMinUsage Name drsWattsMinUsage Object ID 1.3.6.1.4.
Description Defines the instantaneous chassis current usage (in watts). Syntax DellPowerReading Access Read-only CMC PSU Information The following MIB tables provide information on the chassis power supply units. Table 86. DRsPSUChassisIndex Name drsPSUChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only Table 87. DRsPSUIndex Name drsPSUIndex Object ID 1.3.6.1.4.1.674.
Syntax DellPowerReading Access Read-only Table 92. DRsPSUWattsReading Name drsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU wattage reading. Syntax DellPowerReading Access Read-only Chassis Servers The following MIB tables provide server information for the chassis being monitored by the chassis management controller. Table 93. DRsCMCServerTable Name drsCMCServerTable Object ID 1.3.6.1.4.1.674.10892.2.5.
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.3 Description Defines the Service Tag of the CMC server. Syntax DellString Access Read-only Table 98. DRsServerSlotName Name drsServerSlotName Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.4 Description Defines the slot name of the CMC server. Syntax DellString Access Read-only Table 99. DRsServerSlotNumber Name drsServerSlotNumber Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.5 Description Defines the chassis slot number of the CMC server.
Access Read-only Table 104. DRsServerStorageMode Name drsServerStorageMode Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.10 Description This attribute defines the Storage Mode of the storage sled. Syntax DellCMCServerStorageMode Access Read-only Table 105. DRsServerIntrusionState Name drsServerIntrusionState Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.11 Description This attribute defines the Intrusion State of the CMC server if supported by the server.
Syntax DellStatus Access Read-only Table 110. DrsCASSChangeTime Name drsCASSChangeTime Object ID 1.3.6.1.4.1.674.10892.2.20.10.4 Description Defines the time stamp of the most recent change of the alerting subsystem. Syntax TimeTicks Access Read-only Table 111. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 112.
Syntax DellStatus Access Read-only Table 116. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 117. DRsAlertSystem Name drsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert.
Access Read-only Table 122. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
3 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 123. RAC Traps TrapID Name Description Severity Category Cause Supporte d by RAC Platform 0 CodeStart SNMP agent is initializing itself Information Status RAC power on or reset. All 1 Authentication Failure Request received with an invalid community name Critical Error SNMP request with an invalid community name. All 1001 alertDrscTest TrapEvent The RAC generated a test trap event in response to a user request Information Status A test SNMP trap generated by a RAC.
Table 124.
TrapID Description Severity 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy has returned to Normal Information 2715392 Battery Low (Predictive Failure) Warning 2715520 Battery Low (Predictive Failure) Cleared Information 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Information 487169 CPU Thermal Trip (Over Temperature Shutdown) Critical 487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Inform
TrapID Description Severity 1076996 System Event Log (SEL) Full (Logging Disabled) Critical 2322176 ASR (Automatic System Recovery) Timer Expired Critical 2322177 ASR (Automatic System Recovery) Reset Occurred Critical 2322178 ASR (Automatic System Recovery) Power Down Occurred Critical 2322179 ASR (Automatic System Recovery) Power Cycle Occurred Critical PowerEdge M1000e CMC Traps This section describes the traps that are generated by the SNMP agent of the PowerEdge M1000e CMC.
TrapID Description Category SubCategory Severity 2179 Current sensor reading is within range. Status Events Amperage Informational Current sensor has detected a warning value. Status Events Amperage Minor Current sensor has detected a failure value. Error Events Amperage Critical Description Category SubCategory Severity Battery state has returned to normal; or battery presence had been detected. Status Events Battery Informational Battery is low.
TrapID Description Category SubCategory Severity 2331 Hardware configuration information. Status Events Hardware Configuration Informational Hardware configuration warning. Status Events Hardware Configuration Minor Hardware configuration failure or critical event. Error Events Hardware Configuration Critical Description Category SubCategory Severity IO Virtualization information. Status Events IO Virtualization Informational IO Virtualization warning.
TrapID Description Category SubCategory Severity 2185 Power supply has detected a failure. Error Events Power Supply Critical Description Category SubCategory Severity Power supply is absent. Error Events Power Supply Critical Description Category SubCategory Severity Power usage information. Status Events Power Usage Informational Power usage warning. Status Events Power Usage Minor Power usage failure.
Table 141. Software Configuration Traps TrapID Description Category SubCategory Severity Status Events Software Configuration Informational Software configuration warning. Status Events Software Configuration Minor Software configuration failure. Error Events Software Configuration Critical Description Category SubCategory Severity Temperature sensor value is within range. Status Events Temperature Informational Temperature sensor has detected a warning value.
TrapID Description Category Subcategory Severity 4273 Storage battery failure. Error Events Battery Critical Description Category Subcategory Severity Storage controller information. Error Events Controller Informational Storage controller warning. Error Events Controller Minor Storage controller failure. Error Events Controller Critical Description Category Subcategory Severity Storage enclosure information. Error Events Enclosure Informational Storage enclosure warning.
TrapID Description Category Subcategory Severity Storage power supply failure. Error Events Power Supply Critical Description Category Subcategory Severity Storage Security information. Status Events Security Event Informational Storage Security warning. Status Events Security Event Minor Storage Security failure or critical event Error Events Security Event Critical Category Subcategory Severity Storage Management information.
TrapID Description Category Subcategory Severity 4353 Storage Virtual disk failure. Error Events Virtual Disk Critical SubCategory Severity Chassis Management Controller audit Status Events information. CMC Informational Chassis Management Controller audit Status Events warning. CMC Minor Chassis Management Controller audit Error Events failure or critical event. CMC Critical Audit Traps The Audit Trap group contains traps that fall under the Audit event category. Table 154.
TrapID Description Category SubCategory Severity 8419 Power usage audit information. Status Events Power Usage Informational Power usage audit warning. Status Events Power Usage Minor Power usage audit failure or critical event. Error Events Power Usage Critical Description Category SubCategory Severity Software change audit failure or critical event. Error Events Software Change Critical alert2PowerUsageAuditWarning 8418 alert2PowerUsageAuditFailure 8417 Table 160.
Table 165. Software Change Traps TrapID Description Category Subcategory Severity Status Events Software Change Minor alert2SoftwareChangeUpdateWarning 6314 42 Software change update warning.
4 iDRAC MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 and 8 (iDRAC7 and iDRAC8). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 and iDRAC8 of a system. NOTE: From iDRAC7 firmware release r1.30.
NOTE: iDRAC7 firmware release r1.30.30 or later and iDRAC8 supports SNMP query operations (GET, GETNEXT, GETBULK) through the SNMPv3 protocol. In addition to supporting query operations through the SNMP v1 and SNMP v2c protocols, SNMP User Security Model (USM) is supported. iDRAC SNMP Data Security Features iDRAC firmware supports the following data security features: • SNMP security lockout feature • • iDRAC supports a simply, non-configurable SNMP security lockout feature.
Description This attribute defines the product description of a remote access card. Syntax StringType Access Read-only Table 170. RAC Manufacturer Name racManufacturer Object ID 1.3.6.1.4.1.674.10892.5.1.1.4.0 Description This attribute defines the product manufacturer of a remote access card. Syntax StringType Access Read-only Table 171. RAC Version Name racVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.5.0 Description This attribute defines the product version of a remote access card.
Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.0 Description This attribute defines the service tag of the enclosing chassis. Syntax StringType Access Read-only Table 176. Chassis Name Modular Name chassisNameModular Object ID 1.3.6.1.4.1.674.10892.5.1.2.2.0 Description This attribute defines the chassis name of the modular chassis. The value is zero length if not a modular system. Syntax StringType Access Read-only Table 177. Chassis Model Modular Name chassisModelModular Object ID 1.3.6.1.4.
Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system. Syntax StringType Access Read-only Table 182. System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.5.0 Description This attribute defines the slot number of the blade in the chassis. Syntax StringType Access Read-only Table 183. System Operating System Name Name systemOSName Object ID 1.3.6.1.4.1.674.10892.5.1.3.6.
Table 188. System Rack Slot Name systemRackSlot Object ID 1.3.6.1.4.1.674.10892.5.1.3.11.0 Description This attribute defines the Rack Slot locator of the system. Syntax StringType Access Read-only Table 189. System Model Name Name systemModelName Object ID 1.3.6.1.4.1.674.10892.5.1.3.12.0 Description This attribute defines the model name of the system. Syntax StringType Access Read-only Table 190. System System ID Name systemSystemID Object ID 1.3.6.1.4.1.674.10892.5.1.3.13.
Description This attribute defines the blade geometry for a blade system. (If not applicable, a 'no such name' error is returned.) Syntax BladeGeometryEnum Access Read-only Table 195. System Node ID Name systemNodeID Object ID 1.3.6.1.4.1.674.10892.5.1.3.18.0 Description This attribute defines the node ID of the system. The node ID provides a unique identifier for the system. Syntax StringType Access Read-only Table 196. System OEM OS Version Name systemOEMOSVersion Object ID 1.3.6.1.4.1.
Table 200. Global Storage Status Name globalStorageStatus Object ID 1.3.6.1.4.1.674.10892.5.2.3.0 Description This attribute defines the overall storage status being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 201. System Power State Name systemPowerState Object ID 1.3.6.1.4.1.674.10892.5.2.4.0 Description This attribute defines the power state of the system. Syntax PowerStateStatusEnum Access Read-only Table 202.
Table 204. Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 Description Current state of battery. Possible values: 1. 2. 3. 4. 5. 6. 7. The current state could not be determined. The battery is operating normally. The battery has failed and needs to be replaced. The battery temperature is high or charge level is depleting. The battery is missing or not detected. The battery is undergoing the re-charge phase. The battery voltage or charge level is below the threshold.
Access read-only Controller Table The objects provide information about the Controller Table group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.
Table 214. Controller Roll Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37 Description Severity of the controller state. This is the combined status of the controller and its components.Possible values: 1. 2. 3. 4. 5. 6. Other Unknown OK Non-critical Critical Non-recoverable Syntax ObjectStatusEnum Access read-only Table 215. Controller Component Status Name controllerComponentStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Syntax INTEGER Access read-only Table 219. Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49 Description The patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares. Syntax INTEGER Access read-only Table 220. Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Access read-only Table 224. Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.59 Description Indicates whether hot spare drives would be restored on insertion into the same slot. Syntax BooleanType Access read-only Table 225. Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Access read-only Table 230. Controller Copy Back Mode Name controllerCopyBackMode Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 Description The current copy back mode setting for the controller. Possible values: 1. 2. 3. 4. Not one of the following. Not supported on this controller. Disks assigned as spares could revert back to spare status.
Description The ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possible values: 1. 2. 3. 4. Not one of the following. Not supported. Automatic load balancing is active. Load balancing is inactive. Syntax INTEGER Access read-only Table 235. Controller Max Cap Speed Name controllerMaxCapSpeed Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 Description The maximum speed of the controller.
Description Description Indicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields).Possible values: 1. Not one of the following. 2. Capable of supporting T10 PI. 3. Not capable of supporting T10 PI. Syntax INTEGER Access read-only Table 240. Controller RAID10 Uneven Spans Supported Name controllerRAID10UnevenSpansSupported Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Table 244. Controller High Availability Mode Name controllerHighAvailabilityMode Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.85 Description Indicates the fault-tolerant mode of the controller. Possible values: 1. 2. 3. 4. None Fault Tolerant(Active/Passive) Fault Tolerant(Active/Active) Degraded Syntax INTEGER Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 245. Controller Peer Controller Name controllerPeerController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.
Description The name of the physical disk's manufacturer. Syntax DisplayString Access read-only Table 249. Physical Disk State Name physicalDiskState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4 Description The current state of this physical disk. Possible states: 1. The current state could not be determined. 2. The physical disk is available for use, but no RAID configuration has been assigned. 3. A RAID configuration has been assigned to the physical disk. 4.
Syntax INTEGER Access read-only Table 254. Physical Disk Used Space In MB Name physicalDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17 Description The amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices. Syntax INTEGER Access read-only Table 255. Physical Disk Free Space In MB Name physicalDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Description The status of the physical disk itself without the propagation of any contained component status. Possible values: 1. 2. 3. 4. 5. 6. Other Unknown OK Non-critical Critical Non-recoverable Syntax ObjectStatusEnum Access read-only Table 259. Physical Disk Part Number Name physicalDiskPartNumber Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.27 Description The part number of the disk. Syntax DisplayString Access read-only Table 260.
Description The maximum data transfer speed supported by the disk in Gigbits per second (Gbps).Possible values: 1. 2. 3. 4. 5. 6. 7. The speed could not be determined. 1.5 Gbps 3.0 Gbps 6.0 Gbps 12.0 Gbps 5 GT/s (applicable for NVMe devices). 8 GT/s (applicable for NVMe devices). Syntax INTEGER Access read-only Table 263. Physical Disk Smart Alert Indication Name physicalDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Syntax INTEGER Access read-only Table 268. Physical Disk Remaining Rated Write Endurance Name physicalDiskRemainingRatedWriteEndurance Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.42 Description This property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if the value is not available or not applicable (in the case of HDD media type) the value will be 255. Syntax INTEGER Access read-only Table 269.
Description The security/encryption status of the physical disk. Possible Values: 1. 2. 3. 4. 5. The physical disk supports encryption. The physical disk does not support encryption The physical disk is encrypted. The physical disk is locked by a key. The physical disk is locked by a foreign key. Syntax INTEGER Access read-only Table 273. Physical Disk Form Factor Name physicalDiskFormFactor Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53 Description The form factor of the physical disk.
Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.58 Description The block size (in bytes) of the physical disk. This is not applicable for NVMe devices. Possible values: 1. 512 2. 4096 Syntax INTEGER Access read-only Table 278. Physical Disk Protocol Version Name physicalDiskProtocolVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59 Description Applicable for NVMe devices only. The NVMe protocol version supported by the device. Syntax DisplayString Access read-only Table 279.
Virtual Disk Table The objects provide information about the Virtual disk storage group. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.
Description The write policy used by the controller for write operations on this virtual disk. Possible values: 1. Write Through. 2. Write Back. 3. Force Write Back. Syntax INTEGER Access read-only Table 288. Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11 Description The read policy used by the controller for read operations on this virtual disk. Possible values: 1. No Read Ahead. 2. Read Ahead. 3. Adaptive Read Ahead.
Description The stripe size of this virtual disk. Possible values: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Not one of the following Default 512 bytes 1 kB 2 kB 4 kB 8 kB 16 kB 32 kB 64 kB 128 kB 256 kB 512 kB 1 MB 2 MB 4 MB 8 MB 16 MB Syntax INTEGER Access read-only Table 291. Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 294. Virtual Disk Is Cache Cade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25 Description Indicates whether the virtual disk is being used as a secondary cache by the controller. Syntax BooleanType Access read-only Table 295. Virtual Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.26 Description The cache policy of the physical disks that are part of this virtual disk. Possible values: 1. Enabled 2.
Table 299. Virtual Disk Media Type Name virtualDiskMediaType Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.33 Description List of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device. Syntax DisplayString Access read-only Table 300. Virtual Disk Remaining Redundancy Name virtualDiskRemainingRedundancy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Description The block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1. 512 2. 4096. Syntax INTEGER Access read-only Table 305. Virtual Disk Adapter 1 Access Policy Name virtualDiskAdapter1AccessPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.39 Description Indicates the Access policy of the virtual disk with the virtual adapters. Possible values: 1. No Access. 2. Full Access.
Description Indicates the Access policy of the virtual disk with the virtual adapters. Possible values: 1. No Access. 2. Full Access. Syntax INTEGER Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 309. Virtual Disk Current Active Controller Name virtualDiskCurrentActiveController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.43 Description Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller.
Description Instance number of this enclosure/backplane. Syntax INTEGER Access not-Accessible Table 313. Enclosure Name Name enclosureName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2 Description The enclosure/backplane's name as represented in Storage Management. Syntax DisplayString Access read-only Table 314. Enclosure State Name enclosureState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4 Description The current state of this enclosure/backplane. Possible states: 1. 2. 3.
Table 318. Enclosure Roll Up Status Name enclosureRollUpStatus Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23 Description Severity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1. 2. 3. 4. 5. 6. Other Unknown OK Non-critical Critical Non-recoverable Syntax ObjectStatusEnum Access read-only Table 319. Enclosure Firmware Version Name enclosureFirmwareVersion Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.
Access read-only Table 324. Enclosure PSU Count Name enclosurePSUCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41 Description The number of Power Supply Units (PSU) present in the storage enclosure. Syntax DisplayString Access read-only Table 325. Enclosure EMM Count Name enclosureEMMCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42 Description The number of Enclosure Management Modules (EMM) present in the storage enclosure.
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.47 Description The enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 331. Enclosure Display Name Name enclosureDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48 Description The enclosure/backplane's friendly FQDD as represented in Storage Management. Syntax DisplayString Access read-only Table 332.
Table 335. Enclosure Management Module State Name enclosureManagementModuleState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 Description The current state of this enclosure management module. Possible states: 1. The current state could not be determined 2. The enclosure management module is operating normally 3. The enclosure management module has encountered a hardware problem or is not responding 4.
Access read-only Table 340. Enclosure Management Module Display Name Name enclosureManagementModuleDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 Description The enclosure management module's friendly FQDD as represented in Storage Management. Syntax DisplayString Access read-only Enclosure Fan Table The objects provide information about the Enclosure Fan Table group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release.
Description Indicates the current relative speed of the fan in RPMs. Syntax INTEGER Access read-only Table 345. Enclosure Fan Component Status Name enclosureFanComponentStatus Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15 Description The status of the fan itself without the propagation of any contained component status. Possible values: 1. 2. 3. 4. 5. 6. Other Unknown OK Non-critical Critical Non-recoverable Syntax ObjectStatusEnum Access read-only Table 346.
Table 349. Enclosure Power Supply Name Name enclosurePowerSupplyName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 Description The power supply unit's name as represented in Storage Management. Syntax DisplayString Access read-only Table 350. Enclosure Power Supply State Name enclosurePowerSupplyState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4 Description The current state of this power supply unit. Possible states: 1. 2. 3. 4.
Table 354. Enclosure Power Supply Display Name Name enclosurePowerSupplyDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16 Description The power supply unit's friendly FQDD as represented in Storage Management. Syntax DisplayString Access read-only Enclosure Temperature Probe Table The objects provide information about the Enclosure Temperature Probe Table group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release.
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7 Description The minimum temperature that will force the probe into a warning state. Syntax INTEGER Access read-only Table 359. Enclosure Temperature Probe Min Critical Value Name enclosureTemperatureProbeMinCriticalValue Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 Description The maximum temperature that will force the probe into a warning state. Syntax INTEGER Access read-only Table 360.
Table 364. Enclosure Temperature Probe FQDD Name enclosureTemperatureProbeFQDD Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15 Description The temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 365. Enclosure Temperature Probe Display Name Name enclosureTemperatureProbeDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.
Access Read-only Table 367. Alert Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.5.3.1.2.0 Description Message describing the alert. Syntax StringType Table 368. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 369. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.
Table 374. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For modular systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length). Syntax DisplayString Table 375. Alert Chassis Name Variable Name alertChassisName Object ID 1.3.6.1.4.1.674.10892.5.3.1.10.0 Description For modular systems, the chassis name of the enclosing chassis.
TrapID Description Category SubCategory Severity Battery is low. System Health Battery Event Minor Battery has failed or battery is absent. System Health Battery Event Critical Description Category SubCategory Severity Cable failure or critical event. System Health Cable Critical Description Category SubCategory Severity Chassis Management Controller detected a warning. System Health CMC Minor Chassis Management Controller detected an error.
Table 385. Fiber Channel Traps TrapID Description Category SubCategory Severity Fiber Channel information. System Health Fiber Channel Informational Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event. System Health Fiber Channel Critical Category SubCategory Severity System Health Hardware Config Informational Hardware configuration warning. System Health Hardware Config Minor Hardware configuration failure or critical event.
TrapID Description Category SubCategory Severity 2091 Network information. System Health NIC Config Informational Network warning. System Health NIC Config Minor Network failure or critical event. System Health NIC Config Critical Description Category SubCategory Severity An OS graceful stop occurred; or an OS graceful shut-down occurred. System Health OS Event Informational A critical stop occurred during OS load; or a runtime critical stop occurred.
TrapID Description Category SubCategory Severity Power supply has detected a warning. System Health Power Supply Minor Power supply has detected a failure. System Health Power Supply Critical Description Category SubCategory Severity Power supply is absent. System Health PSU Absent Critical Description Category SubCategory Severity System performance restored. System Health Power Usage Informational System performance degraded.
TrapID Description Category SubCategory Severity 2481 Integrated Dual SD Module is absent. System Health IDSDM Absent Critical Category SubCategory Severity System Health IDSDM Redundancy Informational System Health IDSDM Redundancy Minor Integrated Dual SD Module redundancy is lost. System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Informational Security warning.
TrapID Description Category SubCategory Severity 2163 Temperature sensor value is within range. System Health Temperature Informational Temperature sensor has detected a warning value. System Health Temperature Minor Temperature sensor has detected a failure value. System Health Temperature Critical Category SubCategory Severity Temperature has been above the System Health warning or critical threshold level for a long enough period of time to be considered in a warning state.
TrapID Description Category SubCategory Severity 2170 Voltage sensor has detected a warning value. System Health Voltage Minor Voltage sensor has detected a failure value. System Health Voltage Critical Description Category SubCategory Severity System performance warning. System Health Performance Minor Voltage Probe Failure 2169 Table 411.
Table 415. Fan Traps TrapID Description Category SubCategory Severity Fan information. Storage Fan Event Informational Fan warning. Storage Fan Event Minor Fan failure. Storage Fan Event Critical Description Category SubCategory Severity Physical disk information. Storage Physical Disk Informational Physical disk warning. Storage Physical Disk Minor Physical disk failure.
TrapID Description Category SubCategory Severity 4178 Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. Storage Storage Minor Storage Management has detected a device independent error condition. There is no global status change associated with this trap. Storage Storage Critical Category SubCategory Severity Storage Temperature Informational Storage Temperature Minor Temperature probe failure.
Table 424. CMC Traps TrapID Description Category SubCategory Severity Chassis Management Controller audit information. Audit CMC Informational Chassis Management Controller audit warning. Audit CMC Minor Chassis Management Controller audit failure or critical event. Audit CMC Critical Description Category SubCategory Severity Debug authorized. Audit Debug Informational Debug authorization failed.
TrapID Description Category SubCategory Severity Power supply audit failure or critical event. Audit Power Supply Critical Description Category SubCategory Severity Power usage audit information. Audit Power Usage Informational Power usage audit warning. Audit Power Usage Minor Power usage audit failure or critical event. Audit Power Usage Critical Category SubCategory Severity Audit System Info Informational Power Supply Audit Failure 8329 Table 431.
Table 437. PCI Device Traps TrapID Description Category SubCategory Severity Configuration PCI Device Informational Category SubCategory Severity Configuration Security Event Minor Description Category SubCategory Severity Software configuration warning. Configuration Software Config Minor Software configuration failure. Configuration Software Config Critical Description Category SubCategory Severity The iDRAC generated a test trap event in response to a user request.