Users Guide

Table 49. Valid Parameters Of Omcong Chassis Memorymode Or Omcong Mainsystem Memorymode
name=value pair 1 Description
index=<n> Number of the chassis where the memory module resides (the
default is chassis 0, the main system chassis).
redundancy=spare | mirror | disabled | raid5 | dddc
spare: Disables the memory module that has a correctable
memory event and copies the failing module’s data to a spare
bank.
mirror: Switches the systems to a mirrored copy of the memory
if the failing module has an uncorrectable memory event. In the
mirror mode, the operating system does not switch back to the
original module until the system reboot.
disabled: Indicates that the system is not to use other available
memory modules if uncorrectable memory events are detected.
raid5: Method of system memory conguration. This is logically
similar to the RAID-5 mode used in hard drive storage systems.
This memory mode provides an extra level of memory checking
and error recovery at the expense of some memory capacity.
The RAID mode supported is RAID level 5 striping with rotational
parity.
dddc: The dddc mode enables double device data correction.
This ensures data availability after hard failure of x4 DRAM.
opmode=mirror | optimizer | advecc
mirror: Switches the systems to a mirrored copy of the memory
if the failing module has an uncorrectable memory event. In the
mirror mode, the operating system does not switch back to the
original module until the system reboots.
optimizer: Enables the DRAM controllers to operate
independently in 64-bit mode and provide optimized memory
performance.
advanced ECC (advecc): Enables the two DRAM controllers to
combine in 128-bit mode and provide optimized reliability.
Memory that are not teamed by the controllers is not reported
to the operating system.
Omcong chassis pwrmanagement or omcong mainsystem pwrmanagement
Use the omcong chassis pwrmanagement or omcong mainsystem pwrmanagement command to congure power cap and
manage proles that control power utilization.
NOTE: This command is valid only on systems prior to PowerEdge 12G systems.
The following table displays the valid parameters for the command:
Table 50. Valid Parameters Of Omcong Chassis Pwrmanagement Or Omcong Mainsystem Pwrmanagement
name=value pair 1 name=value pair 2 Description
cong=budget cap=<value>
Sets the threshold value for power
budget.
77