Users Guide
Server Administrator includes a number of services, each having a version number of its own. The Contains eld reports version
numbers for the services and provides other useful details. The output may change depending on the conguration of the system
and the version of Server Administrator.
Table 42. Output
Contains: Broadcom SNMP Agent 10.xx.xx
Common Storage Module 3.x.x
Data Engine 5.x.x
Hardware Application Programming Interface 5.x.x
Instrumentation Service 6.x.x
Instrumentation Service Integration Layer 1.x.x
Intel SNMP Agent 1.xx.x
OpenManage Inventory Collector 6.x.x
OpenManage Tools 6.x.x
Remote Access Controller 4 Data Populator 4.x.x
Remote Access Controller 4 Managed Node 4.6.3
Secure Port Server 1.x.x
Server Administrator Framework 6.x.x
Agent for Remote Access 1.x.x
Storage Management 3.x.x
Sun Java Runtime Environment 1.x.xx
Omcong Chassis Or Omcong Mainsystem
Use the omcong chassis or omcong mainsystem commands to:
• Set to default or assign specic values for fan, voltage, and temperature probes
• Congure BIOS behavior during system start up
• Clear memory error counts
• Enable or disable power button control features if the system conguration permits
Use the omcong chassis -? or omcong mainsystem -? command to view a list of all omcong chassis or omcong mainsystem
commands.
Omcong Chassis Biossetup Or Omcong Mainsystem Biossetup
Use the omcong chassis biossetup or omcong mainsystem biossetup command to congure system BIOS settings that are
normally available only in the BIOS setup boot time settings of the system.
CAUTION: Changing certain BIOS setup options may disable the system or require you to reinstall the operating system.
NOTE: Reboot the system for the BIOS setup options to take eect.
NOTE: Not all BIOS setup options are available on every system.
NOTE: When CSIOR (Collect System Inventory on Restart) is disabled, you cannot congure the BIOS settings using
omcong command.
57