Users Guide

Server Administrator includes a number of services, each having a version number of its own. The Contains eld reports version
numbers for the services and provides other useful details. The output may change depending on the conguration of the system
and the version of Server Administrator.
Table 42. Output
Contains: Broadcom SNMP Agent 10.xx.xx
Common Storage Module 3.x.x
Data Engine 5.x.x
Hardware Application Programming Interface 5.x.x
Instrumentation Service 6.x.x
Instrumentation Service Integration Layer 1.x.x
Intel SNMP Agent 1.xx.x
OpenManage Inventory Collector 6.x.x
OpenManage Tools 6.x.x
Remote Access Controller 4 Data Populator 4.x.x
Remote Access Controller 4 Managed Node 4.6.3
Secure Port Server 1.x.x
Server Administrator Framework 6.x.x
Agent for Remote Access 1.x.x
Storage Management 3.x.x
Sun Java Runtime Environment 1.x.xx
Omcong Chassis Or Omcong Mainsystem
Use the omcong chassis or omcong mainsystem commands to:
Set to default or assign specic values for fan, voltage, and temperature probes
Congure BIOS behavior during system start up
Clear memory error counts
Enable or disable power button control features if the system conguration permits
Use the omcong chassis -? or omcong mainsystem -? command to view a list of all omcong chassis or omcong mainsystem
commands.
Omcong Chassis Biossetup Or Omcong Mainsystem Biossetup
Use the omcong chassis biossetup or omcong mainsystem biossetup command to congure system BIOS settings that are
normally available only in the BIOS setup boot time settings of the system.
CAUTION: Changing certain BIOS setup options may disable the system or require you to reinstall the operating system.
NOTE: Reboot the system for the BIOS setup options to take eect.
NOTE: Not all BIOS setup options are available on every system.
NOTE: When CSIOR (Collect System Inventory on Restart) is disabled, you cannot congure the BIOS settings using
omcong command.
57