Users Guide
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=settempprobes controller=1
enclosure=2 index=3 minwarn=10 maxwarn=40
NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on
controller 1.
Omcong Reset Temperature Probe Thresholds
Table 199. omcong Reset Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default values.
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage enclosure action=resettempprobes controller=id
enclosure=<ENCLOSUREID> index=id, where id is the controller ID and the temperature
probe ID. The <ENCLOSUREID> variable species the enclosure.
In this syntax, n is a user-specied alphanumeric string.
Example to Reset the thresholds for temperature probe 3, residing in the enclosure attached to connector 2 on
controller 1, to the default values.
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=resettempprobes controller=1
enclosure=2 index=3
NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on
controller 1.
Omcong Set All Temperature Probe Thresholds
Table 200. Omcong Set All Temperature Probe Thresholds
Description Sets the minimum and maximum warning temperature thresholds for all temperature probes in the
enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax
omconfig storage enclosure action=setalltempprobes controller=id
enclosure=<ENCLOSUREID> minwarn=n maxwarn=n, where id is the controller ID. The
<ENCLOSUREID> variable species the enclosure.
In this syntax, n is a user-specied alphanumeric string.
Example to Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on
controller 1, to 10 and 40 degree Celsius.
Example for SAS
controllers
omconfig storage enclosure action=setalltempprobes controller=1
enclosure=2:3 minwarn=10 maxwarn=40
Omcong Reset All Temperature Probe Thresholds
Table 201. Omcong Reset All Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default value for all
temperature probes in the enclosure.
174