Users Guide
Omcong Enclosure Commands
The following table provides the omcong command syntax required to execute enclosure tasks.
Table 193. Omcong Enclosure Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs
omcong storage enclosure action=enablealarm controller=id enclosure=<ENCLOSUREID>
action=disablealarm controller=id enclosure=<ENCLOSUREID>
action=setassettag controller=id enclosure=<ENCLOSUREID> assettag=<string>
action=setassetname controller=id enclosure=<ENCLOSUREID> assetname=<string>
action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n
action=resettempprobes controller=id enclosure=<ENCLOSUREID> index=id
action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
action=resetalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
action=blink controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
Omcong Enable Enclosure Alarm
Table 194. Omcong Enable Enclosure Alarm
Description Enables the enclosure alarm
Example to Enable the alarm on the enclosure attached to connector 2 on controller 1.
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=enablealarm controller=1 enclosure=2
Example for SAS
controllers
omconfig storage enclosure action=enablealarm controller=1
enclosure=1:2
Omcong Disable Enclosure Alarm
Table 195. Omcong Disable Enclosure Alarm
Description Disables the enclosure alarm.
Syntax
omconfig storage enclosure action=disablealarm controller=id
enclosure=<ENCLOSUREID>, where idis the controller ID. The <ENCLOSUREID> variable
species the enclosure.
Example to Disables the alarm on enclosure 2 attached to connector 1 on controller 1.
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=disablealarm controller=1
enclosure=2
Example for SAS
controllers
omconfig storage enclosure action=disablealarm controller=1
enclosure=1:2
172