Users Guide

2kb| 4kb| 8kb| 16kb| 32kb| 64kb | 128kb>] [cachepolicy=<d | c>] [diskcachepolicy=<disabled
| enabled>][readpolicy=<ra | nra | ara | rc | nrc>] [writepolicy=<wb| wt| wc| nwc | fwb>]
[name=<string>] [spanlength=<n>] | [secureflag=yes][vdpienabled=yes]
NOTE: If the command-line interface does not support commas (,) as parameter separators, then use double quotation
marks (“) to run the CLI command. Example, use pdisk="0:1:1,0:1:2" instead of
pdisk=0:1:1,0:1:2
.
NOTE: If you are conguring RAID for SAS controllers with rmware version 6.1 and later, spanlength is an optional
parameter (default=2). Spanlength is an even number and is lesser than or equal to half the number of physical disks
specied in size.
NOTE: The vdpienabled is an optional argument and is valid only on PERC9 controllers. If set to yes a T10 Protection
Information (PI) enabled virtual disk is created.
NOTE: For RAID 10 creation, PERC 9 rmware suggests the layout (number of array disks) with uneven span (spans with
unequal number of array disks), though in a span the number of disks remains even. For example, for 32 disks, RAID 10
gets created with all the disks in one span and for 34 disks, RAID 10 gets created with 16 disks in one span and 18 disks in
the other span.
Example Syntax:
You can create a RAID-5 virtual disk of 500 MB with a stripe size of 16 KB on a PERC 3/QC controller. The name of the virtual disk is
vd1 and it resides on connector 0 of controller 1. Because the virtual disk is a RAID-5, it requires at least three physical disks. In this
example, you specify four physical disks. These are physical disks 0 through 3. The virtual disk has read-ahead, write–through
caching, and cache I/O policies.
To create a virtual disk:
omconfig storage controller action=createvdisk controller=1 raid=r5 size=500m pdisk=
0:0,0:1,0:2,0:3 stripesize=16kb cachepolicy=c readpolicy=ra writepolicy=wt
The only parameters that require specication are for the controller, RAID level, virtual disk size, and physical disk selection. Storage
Management supplies default values for all other unspecied parameters. For more information on read, write, and cache policies
that are supported by the controller, see the Dell OpenManage Online Help.
Parameter specication for creating and reconguring virtual disk
The following table displays how to specify the omcong storage controller action=createvdisk parameters:
Table 155. Parameters And Types
Parameters Type
controller=id Required
raid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> Required
size=<number | max | min> Required
pdisk=<connector:targetID,connector:targetID,.....> Required
[stripesize=<2k b| 4kb | 8kb | 16kb | 32kb | 64kb | 128kb>] Optional
[cachepolicy=<d | c>] Optional
[readpolicy=<ra | nra | ara | rc | nrc>] Optional
[writepolicy=<wb | wt | wc | nwc | fwb>] Optional
[name=<string>] Optional
[spanlength=<n>] parameter Optional
controller=id parameter
Specify the controller ID as reported by the omreport storage controller command. For example,controller=2
159