Users Guide

Event Name Description
event=voltfail Sets action or enables or disables alert generation when a voltage probe detects that the
voltage is too low for proper operation.
event=intdualsdcardcritical Sets actions that Server Administrator performs when an internal dual SD card critical
event occurs.
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card warning is
displayed.
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not
available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual
SD card is lost.
event=watchdogasr Enables or disables alert generation congured by the ASR when the system has hung or
is not responding.
Omcong system snmptraptest or omcong servermodule snmptraptest
Use the omcong system snmptraptest or omcong servermodule snmptraptest command to send the snmp test trap to the
destination address if Server Administrator SNMP component is congured in the conguration le.
The following table displays the valid parameters for the command:
Table 68. Parameters For Alert Action Command
Action Description
dest=<ipv4 address |
ipv6 address | fqdn>
Send the test trap to the destination IP address.
NOTE: This feature is not supported on VMware ESXi.
Omcong System Events Or Omcong Servermodule Events
Use the omcong system events or omcong servermodule events command to enable and disable SNMP traps for the components
on your system.
NOTE: Not all event types are present on the system.
There are four parameters in the name=value pair component of the omcong system events command:
Source
Type
Severity
Index
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event
notication for the system’s components.
omconfig system events source=snmptraps
or
omconfig servermodule events source=snmptraps
110