Example chassis intrusion actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
or
omconfig servermodule alertaction event=intrusion clearall=true
Commands for clearing logs
You can use the omcong system or omcong servermodule command to clear the following logs: the alert log, command log, and
hardware or ESM log.
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
or
omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing the command log
resolves this condition.
To clear the contents of the command log, type:
omconfig system cmdlog action=clear
or
omconfig servermodule cmdlog action=clear
To clear the contents of the ESM log, type:
omconfig system esmlog action=clear
or
omconfig servermodule esmlog action=clear
NOTE: For more information about alert messages, see the
Dell OpenManage Server Administrator Messages Reference
Guide
at dell.com/support/manuals.
Omcong system pedestinations or omcong servermodule pedestinations
Use the omcong system pedestinations or omcong servermodule pedestinations command to set IP addresses for alert
destinations.
The following table displays the valid parameters for the command.
NOTE: You can either specify the index and IP address as parameters together or you can set only the community string
as a parameter.
NOTE: Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address. On 12th generation of PowerEdge
systems with iDRAC7 specic versions, the index can accept IPv4, IPv6, or FQDN.
Table 65. Valid Parameters Of
Omcong System Pedestinations Or Omcong Servermodule Pedestinations
name=Value Pair Description
destenable=true | false
true: Enables an individual platform event lter destination after a valid IP address has been set.
false: Disables an individual platform event lter.
index=number Sets the index for the destination.