Release Notes

DF549057: When an operating system is installed through USC, the BIOS attributes in Server Administrator are displayed as
read-only. You can edit the BIOS attributes 18 hours after the operating system installation.
Workaround: To enable editing of the Server Administrator BIOS attributes, launch Lifecycle Controller while booting.
DF552204: On Mozilla Firefox browsers (versions 10, 11 and 12), Server Administrator fails to launch if IPv6 address is used.
This is a known issue. For more information, see https://bugzilla.mozilla.org/show_bug.cgi?id=633001.
BITS040169: In case of Boot/HDD/UEFI sequence, if they are read-only, then toggle buttons (+ and -) and submit button are
not visible. On the BIOS setup page, dependencies may exist between the various attributes for Bios settings. Setting an
attribute value may change the state of the dependent attributes to non-editable or editable. For example, changing the Boot
Mode to UEFI from the Boot Settings page does not allow you to congure the Boot or Hard-Disk Drive Sequence in the BIOS
Boot Settings page. When the page is non-editable, the toggle buttons on the page allows toggling the order of the boot
sequence. However, settings cannot be congured since Apply button will not available to submit the settings.
BITS050574: On 11th generation and 12th generation of PowerEdge servers running the Linux OS, the omreport system
summary command displays RAC Command Interface as 7.1.0. "RAC Command Interface" is a DRAC4 RPM and its version is 7.1.
It is installed as a dependent package for iDRAC6 and iDRAC7 Command Interface packages.
If a new certicate imported to Server Administrator is not active after restarting the Web server, restore the previous certicate.
To restore the previous certicate, do the following:
a. Stop the Web server.
b. Perform one of the following as applicable:
On systems running Windows:
* Delete the le keystore.db at <installed directory>\Dell\SysMgt\apache- tomcat\conf\
* Rename the le keystore.db.bak at <installed directory>\Dell\SysMgt\apache- tomcat\conf\ to keystore.db
On systems running Linux:
* For 32-bit OS
Delete the keystore.db le at /opt/dell/srvadmin/lib/openmanage/apache- tomcat/conf
Rename the keystore.db.bak at /opt/dell/srvadmin/lib/openmanage/apache- tomcat/conf to keystore.db
* For 64-bit OS
Delete the keystore.db le at /opt/dell/srvadmin/lib64/openmanage/apache- tomcat/conf
Rename the keystore.db.bak at /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to keystore.db
c. Start the Web server.
BITS078118: On 12th generation of PowerEdge servers with specic versions of iDRAC, you cannot set the platform event alert
actions (reboot, shut down, and so on) through Server Administrator. Set the alert actions for the events through iDRAC GUI.
BITS144583: On Mozilla Firefox 21 or later, the Quit browser option does not work after logging out from Server Administrator.
To close the browser or tab, you must manually close the Firefox browser tab.
BITS177670: On Chrome 38 or later, the Quit browser option does not work after logging out from Server Administrator. To
close the browser or tab, you must manually close the Firefox browser tab.
On PowerEdge T430, C4130, and R220 II, with PERC S130 conguration and no backplane, Storage Management displays a
mock backplane which does not support the blink/unblink operation for disks available on this conguration.
BITS256932: The default factory IP for an IDRAC is “192.168.0.120” or “192.168.0.*”, which indicates that the iDRAC IP is not
congured by the user. However, if you choose to congure the default factory IP (static or DHCP) as your iDRAC IP, then the
“Not Congured” value for “iDRAC Network Settings” displayed on the OMSA “System Summary” page can be ignored. Note:
On rack and tower systems, the default factory IP for iDRAC is “192.168.0.120”. On modular systems, the default factory IP range
for iDRAC is “192.168.0.*”, where “*” can be any value from 0 to 255.
BITS265922: The DSM SA Connection will fail to start if Java Runtime Engine 1.8.0 or newer is installed and specied as the
“System JRE” in Preferences of the Server Administrator web GUI. OMSA 8.3 and older is currently not compatible with Java 1.8
or newer. To recover to the default Bundled JRE setting so that the web service starts again, enter the following command line:
omcong preferences webserver attribute=setjre jreversion=bundled
BITS260330/BITS260451:Restart the data manager service, after Intel NIC driver update or NVIDIA graphics driver update is
performed.
JIT-25314: The alert log is not generated in Server Administrator, when the Power Supply Unit (PSU) is inserted in the server
without connecting a power cable for that PSU. However, corresponding log is generated in ESM or Hardware logs.
10