Users Guide
Property Denition
• Degraded — The enclosure has encountered a failure and is operating in
a degraded state. This state does not apply to backplanes.
• Failed — The enclosure or backplane has encountered a failure and is
no longer functioning.
Connector Displays the number of connectors attached to the enclosures or
backplanes. This number matches the number connector on the controller
hardware. Depending on the controller type, the connector can be either a
SCSI channel or a SAS port.
Enclosure ID Displays the enclosure ID assigned to the enclosure by Storage
Management. Storage Management numbers the enclosures attached to
the controller starting with zero. This number is the same as the enclosure
ID number reported by the omreport command. For information on
Command Line Interface, see the Server Administrator Command Line
Interface User’s Guide.
Target ID Displays the SCSI ID of the backplane (internal to the server) or the
enclosure to which the controller connector is attached. The default value is
six.
Conguration Displays the mode in which the enclosure is operating. Possible values are:
• Joined — Indicates that the enclosure is operating in the joined-bus
mode.
• Split — Indicates that the enclosure is operating in the split-bus mode.
• Unied — Indicates that enclosure is operating in the unied mode.
• Clustered — Indicates that the enclosure is operating in cluster mode.
Clustered mode is only available on cluster-enabled RAID controllers. For
more information, see Background Initialization On PERC Controllers.
For more information on joined, split, and cluster modes, see the enclosure
hardware documentation. For information on how to cable the enclosure to
accommodate these dierent modes, see the enclosure hardware
documentation.
The bus conguration switch when toggled on a 220S or 221S enclosure,
the enclosure should be turned o. For more information, see Changing The
Mode On 220S And 221S Enclosures.
Older 200S enclosures with a version 1.8 kernel that only have one EMM
may display Split Bus mode and not Joined Bus mode. Joined Bus or
Clustered modes may display when applicable in these circumstances.
Firmware Version Displays the version of the enclosure rmware.
NOTE: For systems supporting multiple backplanes, the rmware
version appears as upstream and downstream versions.
Service Tag Displays the enclosure Service Tag. The enclosure is identied by a unique
Service Tag number. This information is used to route support calls to the
appropriate personnel.
Express Service Code The enclosure is identied by a unique Express Service Code number. This
information is used to route support calls to the appropriate personnel.
Asset Tag Displays the asset tag information for the enclosure. You can change this
property using the Setting Asset Data task.
94