Reference Guide
Table 16. Managed Node
Port
Number
Protocols Port
Type
Maximum
Encryption
Level
Direction Usage Configurable
21 FTP TCP None Out FTP command client No
443 WSMAN TCP 128-bit In/Out iDRAC/OMSA communication No
135, 136,
137, 138,
139, 445
HTTPS TCP 128-bit All These ports are enabled for iDRAC to
access the CIFS share created by the
Integration gateway.
No
Dell Connections License Manager (DCLM)
Table 17. Management Station
Port Number Protocols Port Type Maximum
Encryption Level
Direction Usage Configurable
8543 HTTP TCP None In/Out DCLM Web Service UI No
8544 HTTP TCP None In/Out DCLM Web Server No
Dell Management Pack for System Center
Operation Manager
Table 18. Management Station
Port
Number
Protocols Port Type Maximum
Encryption
Level
Direction Usage Configurable
161 SNMP UDP None In/Out SNMP Query Management No
162 SNMP UDP None In Event reception through SNMP No
443 WSMAN TCP 128-bit In/Out ESX/iDRAC/Chassis
Communication
No
8543 HTTP TCP None Out DCLM Communication No
8544 HTTP TCP None Out DCLM Web Server Console Launch No
NOTE: Other ports to be accessed or opened as perhttps://technet.microsoft.com/en-in/library/
jj656649.aspx#BKMK_Firewall
Table 19. Managed Node
Port
Number
Protocols Port Type Maximum
Encryption
Level
Direction Usage Configurable
443 WSMAN TCP 128-bit In/Out ESX/iDRAC/Chassis
Communication
No
443 HTTPS TCP 128-bit In RACADM Communication No
161 SNMP UDP None In/Out SNMP Query Management No
162 SNMP UDP None Out Hardware SNMP Events No
2463 SymbolSDK TCP None In PowerVault MD Array
Communication
No
1311 HTTP/HTTPS TCP None In/Out OMSA Web Console No
Ports 17