BITS050574: On 11th generation and 12th generation of PowerEdge servers running the Linux OS, the omreport system summary
command displays RAC Command Interface as 7.1.0. "RAC Command Interface" is a DRAC4 RPM and its version is 7.1. It is installed
as a dependent package for iDRAC6 and iDRAC7 Command Interface packages.
If a new certificate imported to Server Administrator is not active after restarting the Web server, restore the previous certificate. To
restore the previous certificate, do the following:
1. Stop the Web server.
2. Perform one of the following as applicable:
On systems running Windows:
Delete the file keystore.db at <installed directory>\Dell\SysMgt\apache- tomcat\conf\
Rename the file keystore.db.bak at <installed directory>\Dell\SysMgt\apache- tomcat\conf\ to
keystore.db
On systems running Linux:
For 32-bit OS
Delete the keystore.db file at /opt/dell/srvadmin/lib/openmanage/apache- tomcat/conf
Rename the keystore.db.bak at /opt/dell/srvadmin/lib/openmanage/apache- tomcat/conf to
keystore.db
For 64-bit OS
Delete the keystore.db file at /opt/dell/srvadmin/lib64/openmanage/apache- tomcat/conf
Rename the keystore.db.bak at /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to
keystore.db
3. Start the Web server.
BITS078118: On 12th generation of PowerEdge servers with specific versions of iDRAC, you cannot set the platform event alert
actions (reboot, shut down, and so on) through Server Administrator. Set the alert actions for the events through iDRAC GUI.
BITS144583: On Mozilla Firefox 21 or later, the Quit browser option does not work after logging out from Server Administrator. To
close the browser or tab, you must manually close the Firefox browser tab.
BITS177670: On Chrome 38 or later, the Quit browser option does not work after logging out from Server Administrator. To close the
browser or tab, you must manually close the Firefox browser tab.
On PowerEdge T430, C4130, and R220 II, with PERC S130 configuration and no backplane, Storage Management displays a mock
backplane which does not support the blink/unblink operation for disks available on this configuration.
BITS256932: The default factory IP for an IDRAC is “192.168.0.120” or “192.168.0.*”, which indicates that the iDRAC IP is not
configured by the user. However, if you choose to configure the default factory IP (static or DHCP) as your iDRAC IP, then the “Not
Configured” value for “iDRAC Network Settings” displayed on the OMSA “System Summary” page can be ignored. Note: On rack and
tower systems, the default factory IP for iDRAC is “192.168.0.120”. On modular systems, the default factory IP range for iDRAC is
“192.168.0.*”, where “*” can be any value from 0 to 255.
BITS265922: The DSM SA Connection will fail to start if Java Runtime Engine 1.8.0 or newer is installed and specified as the “System
JRE” in Preferences of the Server Administrator web GUI. OMSA 8.3 and older is currently not compatible with Java 1.8 or newer. To
recover to the default Bundled JRE setting so that the web service starts again, enter the following command line: omconfig
preferences webserver attribute=setjre jreversion=bundled
BITS260330/BITS260451:Restart the data manager service, after Intel NIC driver update or NVIDIA graphics driver update is
performed.
JIT-25314: The alert log is not generated in Server Administrator, when the Power Supply Unit (PSU) is inserted in the server without
connecting a power cable for that PSU. However, corresponding log is generated in ESM or Hardware logs.
JIT-22805: Server Administrator does not recommend the upgrade to major versions of JRE. For more details, see the release notes
of Server Administrator (packaged with Server Administrator application) or at dell.com/openmanagemanuals.
JIT-31814: OpenManage Server Administrator Cannot show the SNMP test trap destination addresses, when admin configured
through domain policy.
JIT-36610/JIT-36599: In OpenManage Server Administrator slots page, the Dell “HBA330 Adapter” PERC card will be enumerated as
“12GB/s HBA internal” and Dell “HBA330 Mini” PERC card will be enumerated as “SAS3008 PCI-Express Fusion-MPT SAS-3
Issues for Remote Access
NOTE:
The Remote Access Service is supported on 11th generation of PowerEdge servers only. The following subsections list
the currently known issues regarding implementation and operation of your RAC and the Remote Access Service in Server
Administrator.