Dell OpenManage SNMP Reference Guide Version 8.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2016 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction..................................................................................................................... 7 What’s New in this release................................................................................................................................................. 7 Supported SNMP Versions.................................................................................................................................................
Thermal Group.................................................................................................................................................................118 Thermal Group Tables............................................................................................................................................... 118 Thermal Group Variable Values.................................................................................................................................
Array Disk Enclosure Connection Table....................................................................................................................363 Array Disk Channel Connection Table...................................................................................................................... 365 Fan Table................................................................................................................................................................. 367 Fan Connection Table..
7 Standard Data Type Definitions...................................................................................434 Common Data Types..................................................................................................................................................... 434 Variables with Data Types of State Capabilities and State Capabilities Unique...............................................................434 Dell Status Data Types........................................................
1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to SNMP Reference Guide, explains the SNMP Reference Guide design.
Table 2. Managed Object Used in This Document MIB Name Agent / Hardware Supported Purpose of the MIB 10892.mib Server Administrator Provides the information about the systems monitored by Server Administrator instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.mib Server Administrator Provides the information about the system Field Replaceable Unit (FRU) to SNMP management applications. dcstorag.
Table 3.
Server Administrator Baseboard Management Controller, ASF MIB The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.. The BMC MIB adheres to ASF 2.0 standard and hence the enterprise ID is wired for management (3183).
Table 5. Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group — provides information about field replaceable units that may be present in your system 2000 Server Administrator Change Management MIB The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications.
Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into twodimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects.
Table 10. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 11. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 12. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
4. BIOS Variable Values — This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table. Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at dell.com/support/manuals.
interfaces, and characteristics of components of the IP on the system. In addition to the standard MIBs, many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices. Monitored data can be retrieved through SNMP using the Get command. Typically, this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve.
request could power off a system, reconfigure a redundant array of independent disks (RAID) card, and so on. Dell has chosen not to support SNMP Set operations for this reason. NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public. For security reasons, change the SNMP community names from their default values.
2 Server Administrator Group The Server Administrator group comprises of the following sections: • Instrumentation MIB Version Group • Systems Management Software Group • System State Group • Chassis Information Group • Operating System Group • System Resource Group • Power Group • Thermal Group • Remote Flash BIOS Group • Port Group • Device Group • Slot Group • Memory Group • BIOS Setup Control Group • Local Response Agent Group • Cost of Ownership Group • Cluster Group •
Syntax DellUnsigned8BitRange Access Read-only Management Information Base Minor Version Number Table 15. Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes.
Systems Management Software The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table. Table 17. Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name.
Table 22. Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.6 Description Defines the preferred systems management standard for the systems management software. Syntax SMSSupportedTypes (Systems Management Software Supported Standards) Access Read-only Table 23. Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelName Object ID 1.3.6.1.4.1.674.10892.1.100.
Access Read-only Table 28. Systems Management Software SNMP Agent Feature Flags Name systemManagementSoftwareSNMPAgentFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.100.12 Description Defines the features of the SNMP agent software provided by the operating system. Syntax SMSSNMPAgentFeatureFlags (Systems Management Software SNMP Agent Feature Flags) Access Read-only Table 29. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.
Possible Data Values Meaning of Data Value none(0) The Systems Management Software SNMP agent features are not enabled. supportsSparseTables(1) The SNMP agent supports sparse tables. System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system.
List 2 Variables that provide health status of each component in associated subsystem in chassis: • systemStatePowerSupplyStatusDetails • systemStateVoltageStatusDetails • systemStateAmperageStatusDetails • systemStateCoolingDeviceStatusDetails • systemStateTemperatureStatusDetails • systemStateMemoryDeviceStatusDetails • systemStateChassisIntrusionStatusDetails • systemStateACPowerCordStatusDetails • systemStatePowerUnitStatusList • systemStateCoolingUnitStatusList • systemStateACPower
Access Read-only Table 36. System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance. Syntax DellStatus Access Read-only Table 37. System State Chassis State Name systemStateChassisState Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.3 Description Defines the system state of this chassis.
Access Read-only Table 41. System State Power Unit Status Details Name systemStatePowerUnitStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.7 Description Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific power unit. The first byte returned represents the status of the first power unit, the second byte returned represents the status of the second power unit, and so on.
Table 45. System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on.
Syntax DellStatus Access Read-only Table 50. System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.16 Description Defines the status of all amperage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific amperage probe.
Table 54. System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on.
Table 58. System State Temperature Status Combined Name systemStateTemperatureStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.24 Description Defines the status of all temperature probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 59. System State Temperature Status Details Name systemStateTemperatureStatusDetailsly Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 63. System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string.
Table 67. System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.33 Description Defines the overall redundancy status of the AC power switches in this chassis. Syntax DellStatusRedundancy Access Read-only Table 68. System State AC Power Switch Status Details Name systemStateACPowerSwitchStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 72. System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on. The bytes have the same definition type as DellStateSettings.
Table 77. System State Power Unit Status List Name systemStatePowerUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.43 Description Lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 78.
Syntax Octet String Access Read-only Table 82. System State Redundant Memory Unit Status Combined Name systemStateRedundantMemoryUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48 Description Defines the combined status of all redundant memory units of this chassis. Syntax DellStatus Access Read-only Table 83. System State Redundant Memory Unit Status List Name systemStateRedundantMemoryUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Syntax DellStatus Access Read-only Table 87. System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus.
Description Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, and so on. The bytes have the same definition type as DellStatus.
Table 94. Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis is numbered one. Syntax DellObjectRange Access Read-only Table 95. Chassis State Capabilities Name chassisStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.2 Description Defines the capabilities of the chassis. Syntax DellStateCapabilities Access Read-only Table 96.
Access Read-only Table 100. Chassis Name Name chassisName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.7 Description Defines the user-assigned chassis name of the chassis. Syntax DellString Access Read-only Table 101. Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Table 102. Chassis Model Name Name chassisModelName Object ID 1.3.6.1.
Access Read-only Table 106. Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Table 107. Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.14 Description Defines the chassis class of this chassis. Syntax DellChassisSystemClass (See Chassis Type) Access Read-only Table 108.
Access Read-only Table 112. Chassis System Primary User Name Name chassisSystemPrimaryUserName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.19 Description Defines the user-assigned primary user name for this chassis. Syntax DellString Access Read-only Table 113. Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system.
Access Read-only Table 118. Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis. Syntax DellLEDControlSettings (See Front-Panel LED Control Settings) Access Read-only Table 119. Chassis Hard-Drive (HD) Fault Clear Control Capabilities Name chassisHDFaultClearControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Access Read-only Table 124. Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31 Description Defines the capabilities of the host control object. Syntax DellHostControlCapabilities (See Host Control Capabilities) Access Read-only Table 125. Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Syntax DellUnsigned16BitRange Access Read-only Table 130. Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.37 Description Specifies whether Simple Network Management Protocol (SNMP) Set type commands are allowed by Server Administrator. This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP master agent. Syntax DellBoolean Access Read-only Table 131.
Description Defines the chassis reseller product name. Syntax DisplayString Access Read-only Table 136. Chassis Reseller System ID Name chassisResellerSystemID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43 Description Defines the chassis reseller system ID. Syntax DellUnsigned16BitRange Access Read-only Table 137. Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 141. Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48 Description Defines the revision name of the system, if applicable. Syntax DellString Access Read-only Table 142. Chassis Express Service Code Name Name chassisExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.49 Description Defines the express service code of the chassis. Syntax DellString Access Read-only Table 143.
Table 146. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 147. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 148. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Table 151. POST Log Table Entry Name postLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.30.1 Description Defines the POST Log Table entry. Syntax PostLogTableEntry Access Not accessible Index postLogchassisIndex , postLogRecordIndex Table 152. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 153.
Table 156. POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 157. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format) Access Read-only Event Log Table Table 158.
Table 161. Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2 Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Table 162. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Table 163.
Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory Table 167. Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Table 168.
Table 171. System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only Table 172. System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object. Syntax DellStateCapabilities Access Read-only Table 173.
Description Defines the release date of the system BIOS. Syntax DellDateName Access Read-only Table 177. System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8 Description Defines the version name of the system BIOS. Syntax DellString Access Read-only Table 178. System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9 Description Defines the starting address of the system BIOS.
the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value. Bits 48-63 need to be examined in the context of the system ID. The system ID is available in the attribute chassisID.
Table 182. System BIOS Characteristics Ext 1 Name systemBIOSCharacteristicsExt1 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13 Description Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Index firmwarechassisIndex , firmwareIndex Table 186. Firmware Chassis Index Name firmwarechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 187. Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2 Description Defines the index (one-based) of the firmware in this chassis. Syntax DellObjectRange Access Read-only Table 188.
Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned16BitRange Access Read-only Table 192. Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Table 193. Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type.
Table 197. Intrusion Table Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.70 Description Defines the Intrusion Table. Syntax SEQUENCE OF IntrusionTableEntry Access Not accessible Table 198. Intrusion Table Entry Name intrusionTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.70.1 Description Defines the Intrusion Table entry. Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex , intrusionIndex Table 199.
Syntax DellStateSettings Access Read-only Table 203. Intrusion Status Name intrusionStatus Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.5 Description Defines the status of the intrusion object. Syntax DellStatus Access Read-only Table 204. Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Table 205. Intrusion Type Name intrusionType Object ID 1.
Table 208. Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex , baseBoardIndex Table 209. Baseboard Chassis Index Name baseBoardchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 210.
Syntax DellStatus Access Read-only Table 214. Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.6 Description Defines the features of the baseboard.. Syntax DellBaseBoardFeatureFlags Access Read-only Table 215. Baseboard Type Name baseBoardType Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7 Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Table 216.
Syntax DellString Access Read-only Table 220. Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name.. Syntax DellString Access Read-only Table 221. Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Table 222.
Data Type: Integer Possible Data Values Meaning of Data Value raw(1) The log is in the format received from the firmware. ascii(2) The log is in ASCII format. uniCode(3) The log is in Unicode format. Table 226. Chassis Type Variable Name : DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis type is not one of the following: unknown(2) The chassis type is unknown. desktop(3) The chassis type is a desktop.
multiSystemChassis( The chassis type is a multisystem chassis. 25) Table 227. Connection Status Variable Name : DellConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 228.
alertOnWarningAndEr The LED control is set to alert on an error or a warning ror(4) condition. Table 231. Hard-Drive Fault LED Control Capabilities Variable Name : DellHDFaultLEDControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilitie s(1) The hard-drive fault LED capabilities are unknown.
resetAndEnable(10) The hard-drive fault LEDs have been reset and enabled. NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis. Table 234.
manualPowerOffWithO The operator can power off with operating system SShutd shutdown. ownCapable(64) manualPowerOffWitho The operator can power off without operating system utOSSh shutdown. utdownCapable(128) manualPowerCycleWit The operator can power cycle with operating system hOSShu shutdown. tdownCapable(256) manualPowerCycleWit The operator can power cycle without operating system houtOS shutdown. ShutdownCapable(512 ) Table 236.
automaticAllExceptN Watchdog controls can be set to automatically perform otificationCap all functions except notification capable. able(27) automaticFullyCapab Watchdog controls can be set to automatically perform le(31) all functions. Table 238. Watchdog Control Settings Variable Name : DellWatchControlSettings NOTE: The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding.
Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no settings capabilities. unknown(1) The power button settings are unknown. enabled(2) The power button state is enabled. disabled(4) The power button state is disabled. Table 242. NMI Button Control Capabilities Variable Name : DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities.
other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwitch( The baseboard type is a connectivity switch. 4) systemManagementMod The baseboard type is a system management module. ule(5) processorModule(6) The baseboard type is a processor module. ioModule(7) The baseboard type is an I/O module. memoryModule(8) The baseboard type is a memory module daughterBoard(9) The baseboard type is a daughter board.
powerSupplyParallel The firmware type is Power Supply Paralleling Board. ingBoard(5) systemBackPlane(6) The firmware type is System (Primary) Backplane. powerVault2XXSKerne The firmware type is Dell PowerVault 2XXS Kernel. l(7) powerVault2XXSAppli The firmware type is PowerVault 2XXS Application. cation(8) frontPanel(9) The firmware type is Front Panel Controller. baseboardManagement The firmware type is Baseboard Management Controller.
boardIsHotSwappabl e(16) This baseboard is hot swappable. Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system. Operating System Memory Table Table 249. Operating System Memory Table Name operatingSystemMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.400.20 Description Defines the Operating System Memory Table.
Access Read-only Table 254. Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory. Syntax DellStatus Access Read-only Table 255. Operating System Memory Total Physical Size NOTE: operatingSystemMemoryTotalPhysicalSize is no more used. This attribute is deprecated and replaced by operatingSystemMemoryExtTotalPhysicalSize.
Description Defines the total virtual memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 260. Operating System Memory Available Virtual Size Name operatingSystemMemoryAvailableVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.10 Description Defines the available virtual memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 261.
Table 263. System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex , systemResourceMapIndex Table 264. System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis.
Syntax DellStatus Access Read-only Table 269. System Resource Map Type Name systemResourceMapType Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.6 Description Defines the type of this system map. Syntax DellSystemResourceMapType (System Resource Map Type) Access Read-only System Resource Owner Table Table 270. System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20 Description Defines the System Resource Owner Table.
Access Read-only Table 274. System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner. Syntax DellStateCapabilities Access Read-only Table 275. System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner.
Access Read-only Table 280. System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis. Syntax DellObjectRange Access Read-only System Resource Input/Output (I/O) Port Table Table 281. System Resource Input/Output (I/O) Port Table Name systemResourceIOPortTable Object ID 1.3.6.1.4.1.674.10892.1.500.
Table 285. System Resource I/O Port State Capabilities Name systemResourceIOPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3 Description Defines the capabilities of the system resource I/O port. Syntax DellStateCapabilities Access Read-only Table 286. System Resource I/O Port State Settings Name systemResourceIOPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.4 Description Defines the state and allows the setting of the system resource I/O port.
Table 291. System Resource I/O Port Ending Address Name systemResourceIOPortEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9 Description Defines the 64 bits of the ending address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Table Table 292. System Resource Memory Table Name systemResourceMemoryTable Object 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table.
Description Defines the capabilities of this system resource memory. Syntax DellObjectRange Access Read-only Table 297. System Resource Memory State Settings Name systemResourceMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.4 Description Defines the state of this system resource memory. Syntax DellObjectRange Access Read-only Table 298. System Resource Memory Status Name systemResourceMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
Description Defines the 64 bits of the ending address of the system resource memory. Syntax DellUnsigned64BitRange Access Read-only Table 303. System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (Resource Memory Flags) Access Read-only System Resource Interrupt Table Table 304.
Access Read-only Table 308. System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt. Syntax DellStateCapabilities Access Read-only Table 309. System Resource Interrupt State Settings Name systemResourceInterruptStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.4 Description Defines the state of this system resource interrupt.
Access Read-only Table 314. System Resource Interrupt Type Name systemResourceInterruptType Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.9 Description Defines the interrupt type of the system resource interrupt. Syntax DellResourceInterruptType (Resource Interrupt Type) Access Read-only Table 315. System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt.
Table 319. System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only Table 320. System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only Table 321.
Table 325. System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only Table 326. System Resource DMA Transfer Width Name systemResourceDMATransferWidth Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.9 Description Defines the transfer width of the system resource DMA.
typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 330. Resource Share Disposition Variable Name: DellResourceShareDisposition Data Type: Integer Possible Data Values Meaning of Data Value shareIsOther(1) The share disposition is not one of the following: shareIsUnknown(2) The share disposition is unknown (not known or not monitored). shareIsDeviceExclusive(3) The share disposition is device exclusive.
interruptIsActiveWhenHigh( 2) The interrupt trigger is active on a high signal. Table 334. Resource DMA Bus Master Variable Name: DellResourceDMABusMaster Data Type: Integer Possible Data Values Meaning of Data Value dmaIsOther(1) The DMA bus master capability is not one of the following: dmaIsUnknown(2) The DMA bus master capability is unknown. dmaIsNotABusmaster(3) The DMA does not have bus master capability. Table 335.
• AC Power Cord Table • Battery Table • Power Usage Table • Power ProfileTable Power Unit Table Table 336. Power Unit Table Name powerUnitTable Object ID 1.3.6.1.4.1.674.10892.1.600.10 Description Defines the Power Unit Table. Syntax PowerUnitTableEntry Access Not accessible Table 337. Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry.
Table 341. Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4 Description Defines the state and settings of the power unit. Syntax DellStateSettings Access Read-only Table 342. Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit. Syntax DellStatusRedundancy Access Read-only Table 343.
Access Not accessible Table 347. Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.12.1 Description Defines the Power Supply Table entry. Syntax PowerSupplyTableEntry Access Not accessible Index powerSupplychassisIndex, powerSupplyIndex Table 348. Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis.
Syntax DellStatus Access Read-only Table 353. Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Table 354. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply.
Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply. Syntax DellPowerSupplySensorState (Power Supply Sensor State) Access Read-only Table 359. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor.
Voltage Probe Table Table 364. Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table. Syntax VoltageProbeTableEntry Access Not accessible Table 365. Voltage Probe Table Entry Name voltageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.20.1 Description Defines the Voltage Probe Table entry. Syntax VoltageProbeTableEntry Access Not accessible Index voltageProbechassisIndex, voltageProbeIndex Table 366.
Syntax DellStateSettings Access Read-only Table 370. Voltage Probe Status Name voltageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.5 Description Defines the status of the voltage probe. Syntax DellStatusProbe Access Read-only Table 371. Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading.
Description Defines the value of the voltage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 376. Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11 Description Defines the user-assigned value of the voltage probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 377.
Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellVoltageDiscreteReading Access Read-only Amerage Probe Table Table 382. Amerage Probe Table Name amperageProbeTable Object ID 1.3.6.1.4.1.
Table 386. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Table 387. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4 Description Defines the state and settings of the amperage probe. Syntax DellStateSettings Access Read-only Table 388.
Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Table 391. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis. Syntax DellString Access Read-only Table 392. Amperage Probe Upper Nonrecoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Table 396. Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.13 Description Defines the value of the amperage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Table 397. Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Description Defines the AC Power Switch Table entry. Syntax ACPowerSwitchTableEntry Access Not accessible Index aCPowerSwitchchassisIndex , aCPowerSwitchIndex Table 402. AC Power Switch Chassis Index Name aCPowerSwitchChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1 Description Defines the index (one-based) of the chassis containing this AC power switch. Syntax DellObjectRange Access Read-only Table 403. AC Power Switch Index Name aCPowerSwitchIndex Object ID 1.3.6.1.4.1.674.
Table 407. AC Power Cord Count for Redundancy Name aCPowerCordCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.6 Description Defines the total number of AC power cords required for this AC power switch to have redundancy. Syntax DellObjectRange Access Read-only Table 408. AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch. Syntax DellString Access Read-only Table 409.
Access Not accessible Index aCPowerCordchassisIndex , aCPowerCordIndex Table 413. AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1 Description Defines the index (one-based) of the chassis containing this AC power cord. Syntax DellObjectRange Access Read-only Table 414. AC Power Cord Index Name aCPowerCordIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2 Description Defines the index (one-based) of this AC power cord.
Table 418. AC Power Cord AC Power Switch Index Reference Name aCPowerCordaCPowerSwitchIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.6 Description Defines the index (one-based) to the associated AC power switch for this AC power cord. Syntax DellObjectRange Access Read-only Table 419. AC Power Cord Location Name Name aCPowerCordLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.7 Description Defines the location name of this AC power cord.
Access Read-only Table 424. Battery State Capabilities Name batteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.3 Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Table 425. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-only Table 426.
Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Table 430. Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.1 Description Defines the Power Usage Table Entry. Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex , powerUsageIndex Table 431. Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Description Defines the status of the power usage information. Syntax DellStatus Access Read-only Table 436. Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Table 437. Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 441. Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.11 Description Defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured. Syntax DellDateName Access Read-only Table 442. Power Usage Peak Amps Name powerUsagePeakAmps Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Description Defines the maximum potential power (in Watts) of the system. This is the maximum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Table 447. Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.17 Description Defines the system power cap capabilities. Syntax DellPowerCapCapabilities Access Read-only Table 448.
Power Profile Table Table 452. Power Profile Table Name powerProfileTable Object ID 1.3.6.1.4.1.674.10892.1.600.70 Description Defines the Power Profile Table. Syntax SEQUENCE OF PowerProfileTableEntry Access Not accessible Table 453. Power Profile Table Entry Name powerProfileTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.70.1 Description Defines the Power Profile Table Entry.
Syntax DellPowerProfileType Access Read-only Table 458. Power Profile Custom CPU Management Capabilities Name powerProfileCustomCPUManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.5 Description Defines the custom CPU power and performance management capabilities that are available for the Custom power profile. Syntax DellCPUPowerPerformanceManagementType Access Read-only Table 459.
Table 463. Power Profile Custom Fan Management Setting Name powerProfileCustomFanManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.10 Description Defines the custom fan power and performance management setting for the Custom power profile. Syntax DellFanPowerPerformanceManagementType Access Read-only Power Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 464.
acPowerAndSwitchAreOn PowerSupplyIsOnIsOkAnd Online(242) The power supply is online and OK. Table 466. Power Supply Type Definitions Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsOther(1) The power supply type is not one of the following: powerSupplyTypeIsUnknown(2) The power supply type is unknown (not known or not monitored). powerSupplyTypeIsLinear(3) The power supply type is a linear power supply.
processorMissing(3) The power supply configuration error type is processor missing. Table 469. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt (3) The voltage probe type is a 1.5-volt (V) probe.
amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The amperage probe type is a 3.3-A probe. amperageProbeTypeIs5Volt(5) The amperage probe type is a 5-A probe. amperageProbeTypeIsMinus5Volt(6) The amperage probe type is a –5-A probe. amperageProbeTypeIs12Volt(7) The amperage probe type is a 12-A probe. amperageProbeTypeIsMinus12Volt(8) The amperage probe type is a –12-A probe.
inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2, with no return. inputSourceCord2ReturnCapable(16) Input source is AC power cord 2, with return. inputSourceSharedCapable(32) Input source is shared. Table 474. AC Power Switch Settings Variable Name: DellACPowerSwitchSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power switch’s settings are unknown. inputSourceCord1NoReturn(2) Input source is AC power cord 1, with no return.
acPowerCordHasPower (8) The AC power cord has power. acPowerCordIsActive Source(16) The AC power cord is the active source of AC power. Table 478. Battery Reading Variable Name: DellBatteryReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value predictiveFailure(1) Battery sensor detects predictive failure. failed(2) Battery has failed. presenceDetected(4) Battery presence is detected. Table 479.
Table 482. CPU Power Performance Management Type Variable Name: DellCPUPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) CPU power and performance management type is Maximum Performance. minPower(2) CPU power and performance management type is Minimum Power. osDBPM(4) CPU power and performance management type is OS Demand Based Power Management.
Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
Access Read-only Table 489. Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.3 Description Defines the capabilities of the cooling unit. Syntax DellStateCapabilities Access Read-only Table 490. Cooling Unit State Settings Name coolingUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.4 Description Defines the state and settings of the cooling unit. Syntax DellStateSettings Access Read-only Table 491.
Syntax DellStatus Access Read-only Cooling Device Table Table 495. Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Table 496. Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
Table 500. Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device. Syntax DellStateSettings Access Read-only Table 501. Cooling Device Status Name coolingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.5 Description Defines the status of the cooling device. Syntax DellStatusProbe Access Read-only Table 502.
Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 506. Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10 Description Defines the value of the fan’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 507. Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1.3.6.1.4.
Description Defines the index for the associated system cooling unit in this chassis. Syntax DellObjectRange Access Read-only Table 512. Cooling Device Subtype Name coolingDeviceSubType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.16 Description Defines the cooling device subtype. Syntax DellCoolingDeviceSubType (Cooling Device Subtype) Access Read-only Table 513. Cooling Device Probe Capabilities Name coolingDeviceProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
Index temperatureProbechassisIndex , temperatureProbeIndex Table 517. Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 518. Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2 Description Defines the index of temperature probes in this chassis.
Description Defines the value of the temperature probe. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 523. Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.
Table 528. Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 529. Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Table 533. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored). coolingDeviceTypeIsAFan(3) The cooling device type is a fan. coolingDeviceTypeIsABlower(4) The cooling device type is a centrifugal blower.
Table 536. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM).
Index remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex Table 540. Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 541. Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
Table 545. Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update. Syntax DellDateName Access Read-only Table 546. Remote Flash BIOS Completion Code Name remoteFlashBIOSCompletionCode Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7 Description Defines the completion code of the last BIOS update.
unknown(1) The remote flash BIOS’s capabilities are unknown. enabled(2) The remote flash BIOS update is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The remote flash BIOS’s state is not ready. canceled(8) The remote flash BIOS has been canceled. pending(16) The remote flash BIOS update is pending. other(32) The remote flash BIOS state/setting is not one of the previous values. Table 550.
• Keyboard Port Table • Processor Port Table • Memory Device Port Table • Monitor Port Table • Small Computer System Interface (SCSI) Port Table • Parallel Port Table • Serial Port Table • Universal Serial Bus (USB) Port Table Pointing Port Table Table 551. Pointing Port Table Name pointingPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.10 Description Defines the Pointing Port Table. Syntax IntegerPointingPortTableEntry Access Not accessible Table 552.
Table 555. Pointing Port State Capabilities Name pointingPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.10.3 Description Defines the capabilities of the pointing port. Syntax DellStateCapabilities Access Read-only Table 556. Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-only Table 557.
Syntax DellString Access Read-only Table 561. Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port. Syntax DellGenericPortConnectorType Access Read-only Keyboard Port Table Table 562. Keyboard Port Table Name keyboardPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.20 Description Defines the Keyboard Port Table.
Syntax DellObjectRange Access Read-only Table 566. Keyboard Port State Capabilities Name keyboardPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.3 Description Defines the capabilities of the keyboard port. Syntax DellStateCapabilities Access Read-only Table 567. Keyboard Port State Settings Name keyboardPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4 Description Defines the state and settings of the keyboard port.
Table 571. Keyboard Port Name Name keyboardPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.8 Description Defines the name of the keyboard port. Syntax DellString Access Read-only Table 572. Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Table 573.
Table 576. Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Table 577. Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syntax DellStateCapabilities Access Read-only Table 578.
Syntax DellProcessorPortConnectorType (See Processor Port Connector Types) Access Read-only Table 582. Processor Port Name Name processorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8 Description Defines name of the processor port. Syntax DellString Access Read-only Table 583. Processor Port BIOS Connector Type Name processorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.9 Description Defines the BIOS connector type of the processor port.
Syntax DellObjectRange Access Read-only Table 587. Memory Device Port Index Name memoryDevicePortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.2 Description Defines the index of the memory device port in this chassis. Syntax DellObjectRange Access Read-only Table 588. Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port.
Table 592. Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Memory Device Port Connector Types) Access Read-only Table 593. Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port.
Monitor Port Table Table 597. Monitor Port Table Name monitorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.50 Description Defines the Monitor Port Table. Syntax IntegerMonitorPortTableEntry Access Not accessible Table 598. Monitor Port Table Entry Name monitorPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1 Description Defines the Monitor Port Table entry. Syntax MonitorPortTableEntry Access Not accessible Index monitorPortchassisIndex , monitorPortIndex Table 599.
Access Read-only Table 602. Monitor Port State Settings Name monitorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.4 Description Defines the state of the monitor port. Syntax DellStateSettings Access Read-only Table 603. Monitor Port Status Name monitorPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.5 Description Defines the status of the monitor port. Syntax DellStatus Access Read-only Table 604.
Table 607. Monitor Port BIOS Connector Type Name monitorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.9 Description Defines the name of the BIOS connector type of the monitor port. Syntax DellGenericPortConnectorType Access Read-only Small Computer System Interface (SCSI) Port Table Table 608. Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table.
Table 612. SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only Table 613. SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port. Syntax DellStatus Access Read-only Table 614. SCSI Port Status Name sCSIPortStatus Object ID 1.3.6.1.
Syntax DellString Access Read-only Table 618. SCSI Port BIOS Connector Type Name sCSIPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.9 Description Defines the BIOS connector type of the SCSI port. Syntax DellGenericPortConnectorType Access Read-only Parallel Port Table Table 619. Parallel Port Table Name parallelPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.70 Description Defines the Parallel Port Table.
Syntax DellObjectRange Access Read-only Table 623. Parallel Port State Capabilities Name parallelPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.3 Description Defines the capabilities of the parallel port. Syntax DellStateSettings Access Read-only Table 624. Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port.
Table 628. Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Table 629. Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 630.
Syntax DellBoolean Access Read-only Serial Port Table Table 634. Serial Port Name serialPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.80 Description Defines the Serial Port Table. Syntax IntegerSerialPortTableEntry Access Not accessible Table 635. Serial Port Table Entry Name serialPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1 Description Defines the Serial Port Table entry.
Syntax DellStateCapabilities Access Read-only Table 639. Serial Port State Settings Name serialPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4 Description Defines the state and settings of the serial port. Syntax DellStateSettings Access Read-only Table 640. Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Table 641.
Table 644. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Table 645. Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex , uSBPortIndex Table 650. USB Port Chassis Index Name uSBPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 651. USB Port Index Name uSBPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.
Access Read-only Table 655. USB Port Security State Name uSBPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.6 Description Defines the security settings of the USB port. Syntax DellPortSecurityState Access Read-only Table 656. USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only Table 657.
connectorPortTypeIsHPHIL(6) The pointing port connector type is HPHIL. connectorPortTypeIsBusMouse(7 ) The pointing port connector type is a bus mouse. connectorPortTypeIsADB(8) The pointing port connector type is ADB. connectorPortTypeIsDB9(9) The pointing port connector type is ninepin DB-9. connectorPortTypeIsMicroDIN(1 0) The pointing port connector type is micro Deutsche Industrie Norm (DIN). connectorPortTypeIsAccessBusU SB (11) The pointing port connector type is Access Bus USB.
connectorPortTypeIsNone(6) There is no processor port connector; processor is soldered in place. connectorPortTypeIsLIFSocket(7) The processor port connector type is a low insertion force (LIF) socket. connectorPortTypeIsSlot1(8) The processor port connector type is a slot one. connectorPortTypeIsSlot2(9) The processor port connector type is a slot two. connectorPortTypeIs370PinSocket(10) The processor port connector type is a 370 pin socket. Table 661.
connectorPortTypeIsDB15PinFemale(4) The monitor port connector type is a female DB-15. Table 663. SCSI Port Connector Types Variable Name : DellSCSIPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin.
Table 665. Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry. Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex , pointingDeviceIndex Table 666. Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis.
Syntax DellStatus Access Read-only Table 671. Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6 Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Table 672. Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device.
, keyboardDeviceIndex Table 676. Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 677. Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis. Syntax DellObjectRange Access Read-only Table 678.
Syntax DellStatus Access Read-only Table 682. Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type. Syntax DellString Access Read-only Table 683. Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.8 Description Defines the name of the keyboard layout. Syntax DellString Access Read-only Processor Device Table Table 684.
Table 687. Processor Device Index Name processorDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2 Description Defines the index of the processor device in this chassis. Syntax DellObjectRange Access Read-only Table 688. Processor Device State Capabilities Name processorDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.3 Description Defines the capabilities of the processor device. Syntax DellStateCapabilities Access Read-only Table 689.
Table 693. Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device. Syntax DellString Access Read-only Table 694. Processor Device Status State Name processorDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.9 Description Defines the status state of the processor device.
Access Read-only Table 699. Processor Device Voltage Name processorDeviceVoltage Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.14 Description Defines the voltage powering the processor device in millivolts. A zero (0) indicates the speed is unknown. Syntax DellSigned32BitRange Access Read-only Table 700. Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Syntax DellUnsigned32BitRange Access Read-only Table 705. Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1.
Bit Position Meaning if Set Bit 3 Hyper-Threading (HT) supported Syntax DellUnsigned16BitRange Access Read-only Table 708. Processor Device Brand Name Name processorDeviceBrandName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.23 Description Defines the brand of the processor device. Syntax DellString Access Read-only Table 709. Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
, processorDeviceStatusIndex Table 713. Processor Device Status Chassis Index Name processorDeviceStatusChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 714. Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe.
Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Table 719. Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Table 720. Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.
Access Read-only Table 724. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 725. Cache Device State Capabilities Name cacheDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3 Description Description Defines the capabilities of the cache device. Syntax DellStateCapabilities Access Read-only Table 726.
Syntax DellCacheDeviceType (See Cache Device Type) Access Read-only Table 730. Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Cache Device Location) Access Read-only Table 731. Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device.
Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 736. Cache Device Speed Name cacheDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14 Description Defines the speed of the cache device in nanoseconds. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 737.
Table 741. Cache Device Supported Type Name cacheDeviceSupportedType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.19 Description Defines the type of static random-access memory (SRAM) that the cache device can support. Syntax DellCacheDeviceSupportedType Access Read-only Table 742. Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device.
Table 746. Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Table 747. Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device. Syntax DellStateCapabilities Access Read-only Table 748.
Table 752. Memory Device Location Name Name memoryDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.8 Description Defines the location name of the memory device. Syntax DellString Access Read-only Table 753. Memory Device Error Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Error Count is no longer in use. If you use the Memory Device Error Count attribute, the value returned is always zero, and using the attribute has no effect.
Description Defines if the memory device is a part of a set. A zero (0) indicates that this device is not part of a set. Syntax DellUnsigned32BitRange Access Read-only Table 758. Memory Device Size NOTE: memoryDeviceSize is no longer in use. This attribute is deprecated and replaced by memoryDeviceExtendedSize. Name memoryDeviceSize Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.14 Description Defines the size in KB of the memory device.
Syntax DellSigned32BitRange Access Read-only Table 763. Memory Device Uncorrectable Memory Event Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Uncorrectable Memory Event Count is no longer used. If you use the Memory Device Uncorrectable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceMultiBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Access Read-only Table 768. Memory Device Asset Tag Name Name memoryDeviceAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.24 Description Defines the asset tag of the memory device. Syntax DellString Access Read-only Table 769. Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string.
Syntax DellUnsigned32BitRange Access Read-only Table 772. Memory Device FQDD Name memoryDeviceFQDD Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.26 Description Fully qualified device descriptor (FQDD) of the memory device. Syntax FQDDString Access Read-only Table 773. Memory Device Current Operating Speed Name memoryDeviceCurrentOperatingSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Access Read-only Table 777. Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis. Syntax DellObjectRange Access Read-only Table 778. Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Syntax DellUnsigned32BitRange Access Read-only Table 783. Memory Device Mapped Address Interleave Position Name memoryDeviceMappedAddressInterleavePosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.8 Description Defines the position of the referenced memory in an interleave of the memory device mapped address. Syntax DellUnsigned32BitRange Access Read-only Table 784. Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1.3.6.1.4.1.674.
Table 788. Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry. Syntax GenericDeviceTableEntry Access Not accessible Index genericDevicechassisIndex , genericDeviceIndex Table 789. Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis.
Syntax DellStatus Access Read-only Table 794. Generic Device System Slot Index Reference Name genericDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.6 Description Defines the index of the system slot into which this generic device is plugged. Syntax DellObjectRange Access Read-only Table 795. Generic Device Type Name genericDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.7 Description Defines the type of the generic device.
Table 799. PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 800. PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only Table 801.
Table 805. PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only Table 806. PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only Table 807.
Access Not accessible Table 811. PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1 Description Defines the PCI Device Configuration Table entry. Syntax PCIDeviceConfigurationSpaceTableEntry Access Not accessible Index pCIDeviceConfigurationSpacechassisIndex , pCIDeviceConfigurationSpaceIndex Table 812. PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.
Table 816. PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only Table 817. PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to. Syntax DellObjectRange Access Read-only Table 818.
Network Device Table Table 822. Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table. Syntax SEQUENCE OF NetworkDeviceTableEntry Access Not accessible Table 823. Network Device Table Entry Name networkDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1 Description Defines the Network Device Table Entry.
Table 827. Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4 Description Defines the connection status of the network device. Syntax DellNetworkDeviceConnectionStatus (See Network Device Connection Status) Access Read-only Table 828. Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device.
Table 833. Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device. Syntax DellString Access Read-only Table 834. Network Device IP Address Name networkDeviceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.11 Description Defines the IP address of the network device. Syntax IpAddress Access Read-only Table 835.
Access Read-only Table 839. Network Device Permanent MAC Address Name networkDevicePermanentMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.16 Description Defines the permanent MAC address of the network device. Syntax DellMACAddress Access Read-only Table 840. Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device.
Access Read-only Table 845. Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device. Syntax DellNetworkDeviceTeamingFlags (See Network Device Teaming Flags) Access Read-only Table 846. Network Device TOE Capability Flags Name networkDeviceTOECapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Syntax DellNetworkDeviceiSCSICapabilityFlags (See Network Device iSCSI Capability Flags) Access Read-only Table 851. Network Device iSCSI Enabled Name networkDeviceiSCSIEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28 Description Defines if iSCSI is enabled for the network device. Syntax DellBoolean Access Read-only Table 852. Network Device Capabilities Name networkDeviceCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Access Not accessible Index managedSystemServicesDeviceChassisIndex , managedSystemServicesDeviceIndex Table 856. Managed System Services Device Chassis Index Name managedSystemServicesDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.1 Description Defines the index (one-based) of the chassis that contains the managed system services device. Syntax DellObjectRange Access Read-only Table 857.
Table 861. Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.6 Description Defines the size in Megabytes (MB) of the storage present on the managed system services device. Syntax DellUnsigned32BitRange Access Read-only SD Card Unit Table Table 862. SD Card Unit Table Name sdCardUnitTable Object ID 1.3.6.1.4.1.674.10892.1.1100.110 Description Defines the SD Card Unit Table.
Table 866. SD Card Unit State Capabilities Name sdCardUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.3 Description Defines the state capabilities of the SD Card unit. Syntax DellStateCapabilities Access Read-only Table 867. SD Card Unit State Settings Name sdCardUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.4 Description Defines the state settings of the SD Card unit. Syntax DellStateSettings Access Read-only Table 868.
SD Card Device Table Table 872. SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.112 Description Defines the SD Card Device Table. Syntax SEQUENCE OF SdCardDeviceTableEntry Access Not accessible Table 873. SD Card Device Table Entry Name sdCardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1 Description Defines the SD Card Device Table Entry.
Table 877. SD Card Device Type Name sdCardDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.4 Description Defines the type of the SD Card device. Syntax DellSDCardDeviceType Access Read-only Table 878. SD Card Device Config Capabilities Name sdCardDeviceConfigCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.5 Description Defines the configuration capabilities of the SD Card device. Syntax DellSDCardDeviceConfigCapabilities Access Read-only Table 879.
Table 883. SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.10 Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device. Syntax DellUnsigned32BitRange Access Read-only Table 884. SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
deviceTypeIsATrackPoi nt(5) Device type is a track point. deviceTypeIsAGlidePoi nt(6) Device type is a glide point. deviceTypeIsATouchPa d(7) Device type is a touch pad. Table 888. Processor Device Status State Variable Name:DellProcessorDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user.
deviceTypeIsUnknow n(2) The processor device type is unknown. deviceTypeIsCPU(3) The processor device type is a central processing unit. deviceTypeIsMathPro cessor(4) The processor device type is a math processor. deviceTypeIsDSP(5) The processor device type is a digital signal processor. deviceTypeIsAVideoP rocessor(6) The processor device is a video processor. Table 891.
processorUpgradeIsB ySocket940(17) Upgrade is by Socket 940. processorUpgradeIsB ySocket939(18) Upgrade is by Socket 939. processorUpgradeIsB ySocketmPGA604(19) Upgrade is by Socket mPGA604. processorUpgradeIsB ySocketLGA771(20) Upgrade is by Socket LGA771. processorUpgradeIsB ySocketLGA775(21) Upgrade is by Socket LGA775. processorUpgradeIsB ySocketS1(22) Upgrade is by Socket S1. processorUpgradeIsB ySocketAM2(23) Upgrade is by Socket AM2.
deviceFamilyIsPenti um2(13) The processor family is Pentium II. deviceFamilyIsPenti umMMX(14) The processor family is Pentium MMX. deviceFamilyIsCeler on(15) The processor family is Celeron. deviceFamilyIsXeon( 16) The processor family is Xeon. deviceFamilyIsPenti um3(17) The processor family is Pentium III. deviceFamilyIsPenti um3Xeon(18) The processor family is Pentium III Xeon. deviceFamilyIsPenti um3Step(19) The processor family is Pentium III Speed Step.
deviceFamilyIsPower PC620(37) The processor family is Power PC 620. deviceFamilyIsPower PCx704(38) The processor family is Power PC x704. deviceFamilyIsPower PC750(39) The processor family is Power PC 750. deviceFamilyIsIntel CoreDuo(40) The processor family is Intel Core Duo. deviceFamilyIsIntel CoreDuoMobi le(41) The processor family is Intel Core Duo mobile. deviceFamilyIsIntel CoreSoloMob ile(42) The processor family is Intel Core Solo mobile.
deviceFamilyIsMIPS( 64) The processor family is MIPS deviceFamilyIsMIPSR 4000(65) The processor family is MIPS R4000. deviceFamilyIsMIPSR 4200(66) The processor family is MIPS R4200. deviceFamilyIsMIPSR 4400(67) The processor family is MIPS R4400. deviceFamilyIsMIPSR 4600(68) The processor family is MIPS R4600. deviceFamilyIsMIPSR 10000(69) The processor family is MIPS R10000. deviceFamilyIsSPAR C(80) The processor family is SPARC.
deviceFamilyIsEffic eon8000 (122) The processor family is Efficeon 8000. deviceFamilyIsWeite k(128) The processor family is Weitek. deviceFamilyIsIntel CeleronM(130) The processor family is Intel Celeron M. deviceFamilyIsAMDAt hlon64(131) The processor family is AMD Athlon 64. deviceFamilyIsAMDOp teron(132) The processor family is AMD Opteron. deviceFamilyIsAMDSe mpron(133) The processor family is AMD Sempron.
deviceFamilyIsPARIS C7100LC( 149) The processor family is PA-RISC 7100LC. deviceFamilyIsPARISC7100(150) The processor family is PA-RISC 7100. deviceFamilyIsV30(1 60) The processor family is V30. deviceFamilyIsQuadC oreIntelXeon3200(16 1) The processor family is Quad-Core Intel Xeon processor 3200 Series. deviceFamilyIsDualC oreIntelXeon3000(16 2) The processor family is Dual-Core Intel Xeon processor 3000 Series.
deviceFamilyIsM2(17 7) The processor family is M2. deviceFamilyIsIntel Pentium4HT (179) The processor family is Intel Pentium 4 HT processor. deviceFamilyIsAS40 0(180) The processor family is AS400. deviceFamilyIsAMDAt hlonXP(182) The processor family is AMD Athlon XP. deviceFamilyIsAMDAt hlonMP(183) The processor family is AMD Athlon MP. deviceFamilyIsAMDDu ron(184) The processor family is AMD Duron. deviceFamilyIsIntel PentiumM(185) The processor family is Intel Pentium M.
deviceFamilyIsG4(20 1) The processor family is G4. deviceFamilyIsG5(20 2) The processor family is G5. deviceFamilyIsESA39 0G6(203) The processor family is ESA/390 G6. deviceFamilyIszArch itectur (204) The processor family is z/Architectur base. deviceFamilyIsIntel Corei5(205) The processor family is Intel Core i5 processor. deviceFamilyIsIntel Corei3(206) The processor family is Intel Core i3 processor. deviceFamilyIsVIAC7 -M(210) The processor family is VIA C7-M.
deviceFamilyIsEmbed dedAMDOpert onQuadCore(230) The processor family is Embedded AMD Opteron QuadCore. deviceFamilyIsAMDPh enomTripleC ore(231) The processor family is AMD Phenom Triple-Core. deviceFamilyIsAMDTu rionUltraDu alCoreMobile(232) The processor family is AMD Turion Ultra Dual-Core mobile processor. deviceFamilyIsAMDTu rionDualCor eMobile(233) The processor family is AMD Turion Dual-Core mobile processor. deviceFamilyIsAMDAt hlonDualCor e(234) The processor family is AMD Athlon Dual-Core.
Table 894. Cache Device Level Variable Name:DellCacheDeviceLevel Data Type:Integer Possible Data Values Meaning of Data Value deviceLevelIsOther( 1) Device level is not one of the following: deviceLevelIsUnknow n(2) Device level is unknown. deviceLevelIsPrimar y(3) Device level is primary. deviceLevelIsSecond ary(4) Device level is secondary. deviceLevelIsTertia ry(5) Device level is tertiary. Table 895.
Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1 ) Device type is not one of the following: deviceTypeIsUnknow n(2) Device type is unknown. deviceTypeIsAMouse( 3) Device type is a mouse. deviceTypeIsATrackB all(4) Device type is a track ball. deviceTypeIsATrackP oint(5) Device type is a track point. deviceTypeIsAGlideP oint(6) Device type is a glide point. deviceTypeIsATouchP ad(7) Device type is a touch pad. Table 898.
deviceAssociativity Is32WaySetAssociati ve(11) Device is 32-way Set-Associative. deviceAssociativity Is48WaySetAssociati ve(12) Device is 48-way Set-Associative. deviceAssociativity Is64WaySetAssociati ve(13) Device is 64-way Set-Associative. Table 899.
deviceFormFactorIsO ther(1) Device form factor is not one of the following: deviceFormFactorIsU nknown(2) Device form factor is unknown. deviceFormFactorIsS IMM(3) Device form factor is SIMM. deviceFormFactorIsS IP(4) Device form factor is SIP. deviceFormFactorIsA Chip(5) Device form factor is a chip. deviceFormFactorIsD IP(6) Device form factor is DIP. deviceFormFactorIsZ IP(7) Device form factor is ZIP. deviceFormFactorIsA ProprietaryCard(8) Device form factor is a proprietary card.
deviceTypeIsFLASH(9 ) Device type is FLASH. deviceTypeIsEEPROM( 10) Device type is EEPROM. deviceTypeIsFEPROM( 11) Device type is FEPROM. deviceTypeIsEPROM(1 2) Device type is EPROM. deviceTypeIsCDRAM(1 3) Device type is CDRAM. deviceTypeIs3DRAM(1 4) Device type is 3DRAM. deviceTypeIsSDRAM(1 5) Device type is SDRAM. deviceTypeIsSGRAM(1 6) Device type is SGRAM. deviceTypeIsRDRAM(1 7) Device type is RDRAM. deviceTypeIsDDR(18) Device type is DDR. deviceTypeIsDDR2(19 ) Device type is DDR2.
deviceTypeDetailIsS ynchronous (128) The detailed device type is synchronous. deviceTypeDetailIsC MOS(256) The detailed device type is CMOS. deviceTypeDetailIsE DO(512) The detailed device type is EDO. deviceTypeDetailIsW indowDRAM (1024) The detailed device type is Window DRAM. deviceTypeDetailIsC acheDRAM (2048) The detailed device type is Cache DRAM. deviceTypeDetailIsN onVolatile (4096) The detailed device type is Non-volatile.
eccSingleBitCorrect ionFailureRate(2) Memory device has exceeded the Correctable Memory Event failure rate. eccMultiBitFault(4) Memory device has encountered an Uncorrectable Memory Event. eccSingleBitCorrect ionLoggingDisabled (8) Correctable Memory Event logging for memory device has been disabled. deviceDisabledBySpa reActivation(16) Memory device is disabled because of spare memory activation. Table 906.
NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for TOE capability is not supported. unknown(1) Querying for TOE capability is supported but query returned an error. available(2) Device has TOE capability. notAvailable(4) Device does not have TOE capability. cannotBeDetermined( 8) Querying for TOE capability is supported but an error prevented querying.
Table 911. Network Device Capabilities Variable Name:DellNetworkDeviceCapabilities Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value notSupported(0) Device does not support reporting capabilities through this attribute. supported(1) Device supports reporting capabilities through this attribute. toe(2) Device has TOE capability. iscsiOffload(4) Device has iSCSI Offload capability.
NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following capabilities. sdCapable(1) SD media can be enabled. vFlashCapable(2) Virtual Flash (vFlash) can be enabled. Table 916. SD Card Device Config Settings Variable Name:DellSDCardDeviceConfigSettings Data Type:Integer NOTE: These values are bit fields, so combination values are possible.
failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode. Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots.
Table 922. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 923. System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.3 Description Defines the capabilities of the system slot.
Syntax DellSystemSlotType (System Slot Type) Access Read-only Table 928. System Slot External Slot Name Name systemSlotSlotExternalSlotName Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.8 Description Defines the external connector name of the system slot. Syntax DellString Access Read-only Table 929. System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot.
Table 933. System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 934. System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
systemSlotCanSupportCard16 (1024) The system slot can support PC Card-16. systemSlotCanSupportCardBus (2048) The system slot can support CardBus. systemSlotCanSupportZoomVid eo(4096) The system slot can support Zoom Video. systemSlotCanSupportModem RingResume(8192) The system slot can support modem ring resume. systemSlotCanSupportPMESig nal(16384) The system slot can support Power Management Enable (PME#) signal.
supportsPMEand3P3Vand5VhasAdapterO n(16804) The system slot supports power management event (PME), supplies 3.3 V, and supplies 5 V. The adapter is on. supportsPMEand3P3Vand5VhasAdapter OnandisHotPluggable(16806) The system slot supports PME, supplies 3.3 V, and supplies 5 V. The adapter is on and the system slot is hot pluggable. supportsPMEand3P3VIsSharedand5Vhas AdapterOnandisHotPluggable(17316) The system slot supports PME, supplies 3.3 V, supplies 5 V, and shares a slot opening.
systemSlotIsAGP8X(25) The system slot type is an AGP 8x card. systemSlotIsPCIExpressX1(166) The system slot type is a PCI Express x1. systemSlotIsPCIExpressX2(167) The system slot type is a PCI Express x2. systemSlotIsPCIExpressX4(168) The system slot type is a PCI Express x4. systemSlotIsPCIExpressX8(169) The system slot type is a PCI Express x8. systemSlotIsPCIExpressX16(170) The system slot type is a PCI Express x16. systemSlotIsPCIExpressGen2(171) The system slot type is PCI Express Gen 2.
systemSlotCategoryIsPCMCIA(4) The system slot category is PCMCIA. systemSlotCategoryIsMotherboard(5) The system slot is a motherboard. Table 941. Hot-Plug Bus Width Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIsOther(1) The system slot bus width is not one of following: busWidthIsUnknown(2) The system slot bus width is unknown. busWidthIs8bits(3) The system slot bus width is 8 bits.
• physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or 2 gigabytes (GB) • physicalMemoryArrayTotalNumberSockets = 4 (the example system has four DIMM slots on the motherboard) • physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM installed) The Rank of the DIMM are : • 0 — Unknown • 1 — Single • 2 — Dual • 4 — Quad • 8 — Octal • 16 — Hexa The following object sets up the Physical Memory Array Table: Table 942.
Access Read-only Table 946. Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array. Syntax DellStateCapabilities Access Read-only Table 947. Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array.
Table 951. Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.8 Description Defines the location of the physical memory array. Syntax DellPhysicalMemoryArrayLocation (See Physical Memory Array Location) Access Read-only Table 952. Physical Memory Array Maximum Size NOTE: physicalMemoryArrayMaximumSize is no longer in use. This attribute is deprecated and replaced by physicalMemoryArrayExtendedMaximumSize.
Table 956. Physical Memory Array ECC Error Critical Threshold Name physicalMemoryArrayECCErrorCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.13 Description Defines the value of the physical memory array ECC error critical threshold. Syntax DellSigned32BitRange Access Read-only Table 957. Physical Memory Array ECC Error Noncritical Threshold Name physicalMemoryArrayECCErrorNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Access Not accessible Table 961. Physical Memory Array Mapped Table Entry Name PhysicalMemoryArrayMappedTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1 Description Defines the Physical Memory Array Mapped Table entry. Syntax PhysicalMemoryArrayMappedTableEntry Access Not accessible Index physicalMemoryArrayMappedchassisIndex , physicalMemoryArrayMappedIndex Table 962. Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.
Access Read-only Table 966. Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Table 967. Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
The following object sets up the Physical Memory Configuration Table: Table 971. Physical Memory Configuration Table Name physicalMemoryConfigTable Object ID 1.3.6.1.4.1.674.10892.1.1300.30 Description Defines the Physical Memory Configuration Table. Syntax SEQUENCE OF PhysicalMemoryConfigTableEntry Access Not accessible Table 972. Physical Memory Configuration Table Entry Name physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.30.
Access Read-only Table 976. Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateSettings Access Read-only Table 977. Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration.
Table 981. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging Table This table defines the conditions for logging system memory events. The following object sets up the Physical Memory Logging Table: Table 982.
Table 986. Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging. Syntax DellPhysicalMemoryLoggingCapabilities Access Read-only Table 987. Physical Memory Logging Settings Name physicalMemoryLoggingSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.4 Description Defines the settings of the physical memory logging.
, redundantMemoryUnitIndex Table 991. Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.1 Description Defines the index (one-based) of the chassis associated with the redundant memory unit. Syntax DellObjectRange Access Read-only Table 992. Redundant Memory Unit Index Name redundantMemoryUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.2 Description Defines the index (one-based) of the redundant memory unit.
Table 996. Redundant Memory Unit Name Name redundantMemoryUnitName Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.6 Description Defines the name of the redundant memory unit. Syntax DellString Access Read-only Table 997. Redundant Memory Unit Status Name redundantMemoryUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.7 Description Defines the status of the redundant memory unit.
Syntax DellObjectRange Access Read-only Table 1001. Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Table 1002. Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card.
Table 1006. Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card. 2,147,483,647 indicates an unknown number of sockets. Syntax DellUnsigned32BitRange Access Read-only Table 1007. Physical Memory Card In Use Number Sockets Name physicalMemoryCardInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.
memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card. memoryArrayLocationIsNUBUS(10) The memory array location is a NuBus bus. memoryArrayLocationIsPC98C20(11) The memory array location is a PC-98/C20 option card. memoryArrayLocationIsPC98C24(12) The memory array location is a PC-98/C24 option card. memoryArrayLocationIsPC98E(13) The memory array location is a PC-98/E option card.
redundantMemoryIsActive(8) Redundant memory is active (in use). enabledAndRedundantMemoryIsActive(10) Redundant memory is enabled and in use. Table 1013. Physical Memory Configuration Redundant Capabilities Variable Name: DellPhysicalMemoryConfigRedundantCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory capabilities. unknownCapabilities(1) Redundant capabilities are unknown.
Table 1016. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) Logging is disabled (0), or enabled (1).
Access Not accessible Index biosSetUpControlchassisIndex Table 1019. BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1020. BIOS Setup Control (BSUC) Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Table 1024. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only Table 1025. BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7 Description Defines the state of the numeric lock.
Syntax DellStateSettings Access Read-only Table 1030. BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number. Syntax DellStatus Access Read-only Table 1031. BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Table 1035. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control. Syntax DellString Access Read-only Table 1036. BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique Name bSUCnIFwakeonLanControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Table 1040. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.22 Description Defines the capabilities of the boot sequence. Syntax DellBootSequenceControlCapabilitiesUnique (See Boot Sequence Control Capabilities Unique) Access Read-only Table 1041. BIOS Setup Control Boot Sequence Control Settings Unique Name DellBootSequenceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Description Defines the settings for administrator password control. Syntax DellBIOSPasswordControlSettingsUnique (See BIOS Password Control Settings Unique) Access Read-only Table 1046. BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only Table 1047.
Access Read-Only Table 1051. BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.33 Description Defines the status of the user password control. Syntax DellStatus Access Read-only Table 1052. BIOS Setup Control User Password Verify Name Name bSUCuserPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.34 Description Defines the setup BIOS name of the current user password.
Table 1056. BIOS Setup Control TPM Security Control Status Name bSUCtpmSecurityControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.38 Description Defines the BIOS setup control status of Trusted Platform Module (TPM) security. Syntax DellStatus Access Read-only Table 1057. BIOS Setup Control TPM Security Control Name Name bSUCtpmSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.39 Description Defines the BIOS setup control name of Trusted Platform Module (TPM) security.
Table 1061. SCSI Control Index Name sCSIControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.2 Description Defines the index (one-based) of the SCSI controller in this chassis. Syntax DellObjectRange Access Read-only Table 1062. SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller. Syntax DellStateCapabilities Access Read-only Table 1063.
Access Not accessible Table 1067. Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry. Syntax ParallelPortControlTableEntry Access Not accessible Index parallelPortControlchassisIndex , parallelPortControlIndex Table 1068. Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
Table 1072. Parallel Port Control Status Name parallelPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Table 1073. Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Table 1074.
Index serialPortControlchassisIndex , serialPortControlIndex Table 1078. Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Table 1079. Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB). Table 1084. USB Control Table Name usbControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.50 Description Defines the USB Table. Syntax UsbControlTableEntry Access Not accessible Table 1085. USB Control Table Entry Name usbControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.50.
Access Read-only Table 1089. USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only Table 1090. USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only Table 1091. USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.
Table 1094. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1095. IDE Control Index Name ideControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.2 Description Defines the index (one-based) of the IDE controller in this chassis. Syntax DellObjectRange Access Read-only Table 1096.
Diskette Control Table Table 1100. Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.70 Description Defines the Diskette Control Table. Syntax DisketteControlTableEntry Access Not accessible Table 1101. Diskette Control Table Entry Name disketteControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1 Description Defines the Diskette Control Table entry.
Table 1105. Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.4 Description Defines the control settings for the diskette controller. Syntax DellDisketteControlSettingsUnique (See Diskette Control Settings) Access Read-only Table 1106. Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller.
Table 1110. Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1111. Network Interface Control Index Name networkInterfaceControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.2 Description Defines the index (one-based) of the network interface controller in this chassis.
BIOS Setting Table These MIB objects enable you to track the BIOS settings for your system. NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems. Table 1116. BIOS Setting Table Name biosSettingTable Object ID 1.3.6.1.4.1.674.10892.1.1400.90 Description Defines the BIOS Setting Table. Syntax SEQUENCE OF BiosSettingTableEntry Access Not accessible Table 1117. BIOS Setting Table Entry Name biosSettingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.90.
Table 1121. BIOS Setting Display Name Name biosSettingDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.4 Description Defines the display name of the BIOS setting. Syntax DisplayString Access Read-only Table 1122. BIOS Setting Value Type Name biosSettingValueType Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.5 Description Defines the type of the BIOS setting value. Syntax DellBIOSSettingValueType Access Read-only Table 1123.
Table 1127. BIOS Setting Display Order Name biosSettingDisplayOrder Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.10 Description Defines the recommended display order of the BIOS setting within its BIOS setting group. Syntax DellUnsigned32BitRange Access Read-only Table 1128. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting.
enabled(2) Speaker control is enabled. low(4) Speaker control volume is low. medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 1132. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN.
allFirstCapable(30) Setup BIOS can boot by any of the preceding methods first. Table 1135. Boot Sequence Control Settings Unique Variable Name: DellBootSequenceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence state is unknown. bootFromDisketteFirst(2) Setup BIOS is set to boot by diskette first. bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE hard drive first.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 1139. TPM Security Control Capabilities Variable Name: DellTPMSecurityControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value offCapable(1) TPM security can be Off. onWithPrebootMeasurementsCap able(2) TPM security can be On with Pre-boot Measurements. onWithoutPrebootMeasurements Capable(4) TPM security can be On without Pre-boot Measurements.
enabled(2) Setup BIOS has enabled the parallel port. lpt1(4) Setup BIOS supports parallel port 1. lpt1Enabled(6) Setup BIOS has enabled parallel port 1. lpt2(8) Setup BIOS supports parallel port 2. lpt2Enabled(10) Setup BIOS has enabled parallel port 2. lpt3(16) Setup BIOS supports parallel port 3. Table 1143.
allcomCapable(126) Setup BIOS is capable of enabling or autoconfiguring all serial ports. Table 1145. Serial Port Control Settings Variable Name: DellSerialPortControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Serial port state is unknown. enabled(2) Setup BIOS has enabled the serial port. com1(4) Setup BIOS has selected serial port 1. com1Enabled(6) Setup BIOS has enabled serial port 1. com2(8) Setup BIOS has selected serial port 2.
unknown(1) Unknown setup BIOS network interface capabilities. enableCapable(2) Setup BIOS is capable of enabling the network interface. enableWithoutPXECapable(4) Setup BIOS is capable of enabling the NIF without Pre-boot eXecution Environment (PXE). Table 1149. Network Interface Control Settings Variable Name: DellNetworkInterfaceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Network interface state is unknown.
In the event that a temperature probe determines the temperature is at or over the failure limit, the systems manager can set an action to be taken automatically. Table 1151. LRA Global Settings Table Name lRAGlobalSettingsTable Object ID 1.3.6.1.4.1.674.10892.1.1500.10 Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible Table 1152. LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.
Table 1156. LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4 Description Defines the set of global capabilities that all local response agents may or may not allow to be set or reset. Syntax DellLocalResponseAgentCapabilitiesUnique (LRA Capabilities Definitions) Access Read-only Table 1157. LRA Global Thermal Shutdown Capabilities Unique Name lRAGlobalThermalShutdownCapabilitiesUnique Object ID 1.3.6.1.4.1.674.
Index lRAActionTablechassisIndex , lRAActionTableActionNumberIndex Table 1161. LRA Action Table Chassis Index Name lRAActionTablechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1162. LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
Description When the execute application value is set, provides the following user-assignable LRA information: • • Name of the user application executable path File name to execute Syntax DisplayString (SIZE (0..256) Access Read-only Table 1164. LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4 Description Defines the LRA settings.
warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected. enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning condition is detected. failureCapable(8) The LRA can carry out chassis-determined action(s) when a failure condition is detected. enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected.
• COO Support Information Table • COO Trouble Ticket Table Cost of Ownership Table The following MIB object sets up the Cost of Ownership Table. Table 1168. Cost of Ownership Name cooTable Object ID 1.3.6.1.4.1.674.10892.1.1600.10 Description Defines the Cost of Ownership Table. Syntax SEQUENCE OF CooTableEntry Access Not accessible Table 1169. Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.
Access Read-only Table 1173. COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-only Table 1174. COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system. Syntax DellDateName Access Read-only Table 1175.
Table 1178. COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.9 Description Specifies whether the purchase of this system was expensed. Syntax DellBoolean Access Read-only Table 1179. COO Original Machine Configuration Vendor Name Name cooOriginalMachineConfigurationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.10 Description Defines the vendor name of the system.
Syntax DellDateName Access Read-only Table 1184. COO Extended Warranty Cost Name cooExtendedWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.15 Description Defines the extended warranty cost date for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1185. COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system.
Table 1189. COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1190. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system.
Syntax DellCostofOwnershipString Access Read-only Table 1195. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-only Table 1196. COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
Table 1200. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-only Table 1201. COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system.
Syntax DellCooMonthYearDurationType Access Read-only Table 1206. COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1207. COO Depreciation Method Name Name cooDepreciationMethodName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.38 Description Defines the name of the depreciation method for this system.
Access Not accessible Index cooServiceContractchassisIndex , cooServiceContractIndex Table 1211. COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1212. COO Service Contract Index Name cooServiceContractIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.
Access Read-only Table 1216. COO Service Contract Vendor Name Name cooServiceContractVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.6 Description Defines the name of the service contract provider for this system. Syntax DellCostofOwnershipString Access Read-only COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Table 1217.
Syntax DellObjectRange Access Read-only Table 1221. COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only Table 1222. COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system.
Access Not accessible Table 1226. COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1 Description Defines the COO Warranty Table entry. Syntax CooWarrantyTableEntry Access Not accessible Index cooWarrantychassisIndex , cooWarrantyIndex Table 1227. COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 1231. COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.5 Description Defines the warranty duration type for the system. Syntax DellCOODayMonthDurationType Access Read-only Table 1232. COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6 Description Defines the warranty end date for this system. Syntax DellDateName Access Read-only Table 1233.
Index cooLeaseInformationchassisIndex , cooLeaseInformationIndex Table 1236. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1237. COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system.
Table 1241. COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-only Table 1242. COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
Description Defines the COO Schedule Number Information Table entry. Syntax CooScheduleNumberTableEntry Access Not accessible Index cooScheduleNumberchassisIndex , cooScheduleNumberIndex Table 1247. COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1248.
Syntax DellCostofOwnershipString Access Read-only COO Options Table Table 1252. COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.70 Description Defines the COO Options Table. Syntax SEQUENCE OF CooOptionsTableEntry Access Not accessible Table 1253. COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry.
Syntax DellStateSettings Access Read-only Table 1257. COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1258. COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.
Syntax DellObjectRange Access Read-only Table 1262. COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information. Syntax DellObjectRange Access Read-only Table 1263. COO Maintenance State Name cooMaintenanceState Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.3 Description Defines the state of this system’s maintenance information.
Table 1267. COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.7 Description Defines the maintenance agreement restrictions. Syntax DellCostofOwnershipString Access Read-only COO Repair Table Table 1268. COO Repair Table Name cooRepairTable Object ID 1.3.6.1.4.1.674.10892.1.1600.90 Description Defines the COO Repair Table. Syntax SEQUENCE OF CooRepairTableEntry Access Not accessible Table 1269.
Table 1272. COO Repair State Name cooRepairState Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.3 Description Defines the state of the repair information for this system. Syntax DellStateSettings Access Read-only Table 1273. COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-only Table 1274.
Table 1277. COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1278. COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information. Syntax DellObjectRange Access Read-only Table 1279.
Syntax DellCostofOwnershipString Access Read-only Table 1283. COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem. Syntax DellCostofOwnershipString Access Read-only COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table allows you to track details of any trouble tickets that you open for your system. Table 1284.
Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1288. COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3 Description Defines the trouble ticket information state for this system. Syntax DellStateSettings Access Read-only Table 1289. COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.
transfer(7) The ownership code is transfer. Table 1292. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 1293. COO Day Month Duration Type Variable Name: DellCooDayMonthDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown.
Table 1295. Cluster Table Name clusterTable Object ID 1.3.6.1.4.1.674.10892.1.1800.10 Description Defines the Cluster Table. Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Table 1296. Cluster Table Entry Name clusterTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1 Description Defines the Cluster Table entry. Syntax ClusterTableEntry Access Not accessible Index clusterChassisIndex , clusterIndex Table 1297.
Syntax DellStateSettings Access Read-only Table 1301. Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Table 1302. Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Table 1303. Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.
Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC.
Table 1309. BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.2 Description Defines the index (one-based) of the BMC. Syntax DellObjectRange Access Read-only Table 1310. BMC State Capabilities Name bmcStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.3 Description Defines the state capabilities of the BMC. Syntax DellStateCapabilities Access Read-only Table 1311. BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
Table 1315. BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only Table 1316. BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC. Syntax Octet String Access Read-only Table 1317.
Access Read-only Table 1321. BMC Blade Form Factor Name bmcBladeFormFactorName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.14 Description Defines Blade Form Factor Syntax DellBladeFormFactorType Access Read-only Baseboard Management Controller Serial Interface Table 1322. BMC Serial Interface Table Name bmcSerialInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.20 Description Defines the BMC Serial Interface Table.
Access Read-only Table 1326. BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.3 Description Defines the index (one-based) of the BMC serial interface. Syntax DellObjectRange Access Read-only Table 1327. BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface.
Access Read-only Table 1332. BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9 Description Defines the connection mode settings of the BMC serial interface. Syntax DellBMCSerialConnectionModeSettings Access Read-only Table 1333. BMC Serial Interface Flow Control Name bmcSerialInterfaceFlowControl Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
, bmcLANInterfaceIndex Table 1337. BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1338. BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only Table 1339.
Syntax DellStatus Access Read-only Table 1343. BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface. Syntax DellUnsigned8BitRange Access Read-only Table 1344. BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8 Description Defines the source type of the IP address of the BMC LAN interface.
Syntax DellMACAddress Access Read-only Table 1349. BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13 Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section.
directBasic(8) Direct Basic mode is enabled. directPPP(16) Direct PPP mode is enabled. directTerminal(32) Direct Terminal mode is enabled. Table 1352. BMC Serial Flow Control Type Variable Name:DellBMCSerialFlowControlType Data Type:Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 1353.
iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular). iDRAC6BMC(13) Controller type is Integrated Dell Remote Access Controller 6 (BMC mode). iDRAC7(16) Controller type is Integrated Dell Remote Access Controller 7. iDRAC7Modular(17) Controller type is Integrated Dell Remote Access Controller 7 (Modular). vrtxCMC(18) Controller type is VRTX Chassis Management Controller (CMC).
Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group. Table 1357. Field Replaceable Unit Table Name fruTable Object ID 1.3.6.1.4.1.674.10892.1.2000.10 Description Defines the Field Replaceable Unit table. Syntax SEQUENCE OF FruTableEntry Access Not accessible Table 1358. FRU Table Entry Name fruTableEntry Object ID 1.3.6.1.4.1.
Table 1362. FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.4 Description Defines the state of the FRU information. Some information for the FRU may not be available if the state is other than ok(1). Syntax DellFRUInformationState Access Read-only Table 1363. FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..
Access Read-only Table 1368. FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only Table 1369. FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.11 Description Defines the asset tag of the FRU. Syntax DisplayString (SIZE (0..
3 Storage Management Group The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Syntax Integer Access Read-only Table 1373. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1374. Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only Table 1375.
Access Read-only Table 1378. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Table 1379. Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
Access Read-only Table 1383. Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.4 Description Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent. Syntax Integer Access Read-only Table 1384. Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active.
Table 1388. Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1389. Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.10 Description This entry is obsolete. Refer to 0001 softwareVersion. Syntax DisplayString Access Read-only Table 1390. Agent MIB Version Name agentMibVersion Object ID 1.3.6.1.4.1.674.10893.1.
4: Non-critical 5: Critical 6: Non-recoverable NOTE: This global status should be used by applications other than HP OpenView. HP OpenView should refer to the globalStatus in the root level object group. Syntax DellStatus Access Read-only Table 1393. Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description The previous global status of the system managed by the Storage Management software.
• Controller Table — describes available properties for each controller on the managed system. • Channel Table — describes available properties for each channel on the managed system. • Enclosure Table — describes available properties for each enclosure on the managed system. • Array Disk Table — describes available properties for each physical array disk on the managed system.
Index controllerNumber Table 1397. Controller Number Name controllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.1 Description Identifies the instance number of the controller entry. Syntax Integer Access Read-only Table 1398. Controller Name Name controllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.2 Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: PERC 3/QC 1.
Table 1401. Controller State Name controllerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 Description Identifies the status of the controller's subsystem (which includes any devices connected to it). Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Table 1402. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management.
Table 1405. Controller Cache Size in Megabytes Name controllerCacheSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.9 Description Identifies the controller's current amount of cache memory in megabytes. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Table 1406. Controller Cache Size in Bytes Name controllerCacheSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1410. Controller Host Port Count Name controllerHostPortCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.14 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1411. Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.15 Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte.
Table 1415. Controller C0 Port 0 World Wide Name Name controllerC0Port0WorldWideName Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.19 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1416. Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax DisplayString Access Read-only Table 1421. Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1422. Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1426. Controller C1 Channel Name controllerC1Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.30 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1427. Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax DisplayString Access Read-only Table 1432. Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1433. Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 Description Indicates severity of the controller state.
Syntax DellStatus Access Read-only Table 1435. Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Table 1436. Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm.
Possible values: 1: Enabled 2: Disabled 3: Active (enabled and active) 99: Not Applicable Syntax Integer Access Read-only Table 1440. Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Table 1441. Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.
Table 1444. Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-only Table 1445. Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 Description The rate for patrol read on the controller. Syntax Integer Access Read-only Table 1446. Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.
Description The state of the patrol read. Possible values: 1: Stopped - not running 2: Ready - ready to start 4: Active - is running 8: Aborted - has aborted Syntax Integer Access Read-only Table 1450. Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.54 Description The number of times Patrol Read has been run on this controller. Syntax Integer Access Read-only Table 1451.
Table 1454. Controller Encryption Key Persent Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller. Value: 1 - Yes, 0 - No, 99 - Not Applicable Syntax Integer Access Read-only Table 1455. Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.59 Description Indicates Persistent Hot Spare capability of the controller.
Access Read-only Table 1459. Controller Encryption Mode Name controllerEncryptionMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.63 Description Indicates the current encryption mode of the controller. Value: 0 - No Encryption, 1 - Local Key Management (LKM), 2 - Dell Key Management (DKM), 99 - Not Applicable Syntax Integer Access Read-only Table 1460. Controller CacheCade Name controllerCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Access Read-only Table 1464. Controller Configured Drives SpinUp TimeInterval Name controllerConfiguredDrivesSpinUpTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.68 Description Indicates configured drives spin up time interval in hours. This value is added with configured drives start time to arrive at time window in which configured drives are always spin up. Value: 1 .. 24, 9999 - Undetermined Syntax Integer Access Read-only Table 1465.
Table 1468. Front Chassis Slot Name frontChassisSlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.72 Description Shows the physical slot on the chassis for stash. Syntax Integer Access Read-only Table 1469. Controller Instance Name controllerInstance Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.73 Description Shows the current instance of the controller for stash. Syntax Integer Access Read-only Table 1470.
Table 1473. Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 Description Identifies the instance number of the channel entry. Syntax Integer Access Read-only Table 1474. Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 Description Identifies the name of the channel as represented in Storage Management. The name includes the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Table 1475.
Table 1477. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Table 1478. Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1481. Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel. Syntax DisplayString Access Read-only Table 1482. Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.
8: SAS 9: PCIe Syntax Integer Access Read-only Enclosure Table The following tables describe theavailable properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Table 1484. Enclosure Table Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Table 1485. Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.
Table 1488. Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Table 1489. Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.4 Description The current condition of the enclosure (which includes any devices connected to it.
Table 1492. Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1493. Enclosure Service Tag Name enclosureServiceTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.8 Description The enclosure identification used when consulting customer support. Syntax DisplayString Access Read-only Table 1494.
Description Identifies the enclosure's product identification. This also corresponds to the enclosure type. Syntax DisplayString Access Read-only Table 1498. Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1499. Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Table 1502. Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.17 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1503. Enclosure Configuration Name enclosureConfig Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 Description Identifies the current configuration of the enclosure's backplane.
2: Enabled Syntax Integer Access Read-only Table 1506. Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane. Syntax Integer Access Read-only Table 1507. Enclosure SCSI ID Name enclosureSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.22 Description Identifies the SCSI ID of the controller to which this enclosure is attached.
Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1510. Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.25 Description Durable unique ID for this enclosure. Syntax Integer Access Read-only Table 1511. Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 Description The firmware version of the enclosure.
Table 1514. Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.29 Description Serial number of the enclosure. Syntax DisplayString Access Read-only Table 1515. Enclosure SAS Address Name enclosureSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.30 Description The specified SAS address if this is a SAS enclosure. Syntax DisplayString Access Read-only Table 1516.
Access Read-only Table 1519. Enclosure Express Service Code Name enclosureExpressServiceCode Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.34 Description Express Service Code (ESC) is base 10 converted numerical value of service tag. Syntax DisplayString Access Read-only Array Disk Table This table describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Table 1520. Array Disk Table Name arrayDiskTable Object ID 1.
Access Read-only Table 1524. Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name. Syntax DisplayString Access Read-only Table 1525. Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational.
40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached readonly state. Syntax Integer Access Read-only Table 1526. Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1527.
Table 1530. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Table 1531. Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected. Syntax Integer Access Read-only Table 1532.
Table 1535. Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.14 Description The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte. This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk. Syntax Integer Access Read-only Table 1536.
Table 1540. Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.19 Description Identifies the amount in megabytes of the free space on the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Table 1541. Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Table 1544. Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.23 Description Severity of the array disk state. This is the combined status of the array disk and its components.
Syntax DellStatus Access Read-only Table 1546. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for this disk. Syntax DisplayString Access Read-only Table 1547. Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk. Syntax DisplayString Access Read-only Table 1548.
Table 1551. Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Table 1552. Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure.
Access Read-only Table 1556. Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description The Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd Syntax INTEGER Access Read-only Table 1557. Array Disk Dell Certified Name arrayDiskDellCertified Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.36 Description Indicates if array disk is certified by Dell.
Syntax Octet String Access Read-only Table 1561. Array Disk Encryption Capable Name arrayDiskEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 Description Indicates if physical disk is encryption capable. Value: 1 - Capable, 0 - Not Capable, 99 Not Applicable Syntax Integer Access Read-only Table 1562. Array Disk Encrypted Name arrayDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.41 Description Indicates if the physical disk has encryption enabled.
Access Read-only Table 1566. Array Disk Life Remaining Name arrayDiskLifeRemaining Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.45 Description Provides PCIe SSD device life remaining in percentage. Value: 0..100, 999 Undetermined/Not Applicable Syntax INTEGER Access Read-only Table 1567. Array Disk Driver Version Name arrayDiskDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.46 Description Provides PCIe SSD device driver version. Syntax INTEGER Access Read-only Table 1568.
Access Read-only Table 1570. Array Disk Remaining Rated Write Endurance Name arrayDiskRemainingRatedWriteEndurance Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.49 Description Provides the remaining rated write endurance for SAS/SATA SSD device. Possible Values: 0-100% : Not Available / Not Applicable Syntax DisplayString Access Read-only Table 1571. Array Disk Sector Size Name arrayDiskSectorSize Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Table 1574. Array Disk Negotiated Link Width Name arrayDiskNegotiatedLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.53 Description Provides the information regarding Negotiated Link Width of array disk. Possible Values: 0–8 Syntax INTEGER Access Read-only Table 1575. Non-RAID Disk Cache Policy Name nonRAIDdiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.54 Description Displays the current disk write cache policy of the Non-RAID disk.
NOTE: Only array disks that are part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Enclosure Connection Table. Table 1578. Array Disk Enclosure Connection Table Name arrayDiskEnclosureConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.5 Description Defines the array disk enclosure connection table. Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry Access Not accessible Table 1579.
Access Read-only Table 1583. Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs. Syntax DisplayString Access Read-only Table 1584. Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Channel Connection Table. Table 1587. Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Table 1588.
Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table. Table 1596. Fan Table Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Table 1597. Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Table 1598.
Access Read-only Table 1601. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1602. Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management.
Access Read-only Table 1605. Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1606. Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.9 Description This entry is obsolete.
Table 1610. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1611. Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components.
Table 1613. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Table 1614. Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure.
Access Read-only Table 1618. Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1619. Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.3 Description Identifies the instance number of the fan in the fanTable in the connection.
Syntax SEQUENCE OF PowerSupplyEntry Access Not accessible Table 1623. Power Supply Entry Name powerSupplyEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1 Description Defines the power supply table entry. Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Table 1624. Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry.
1: Ready 2: Failed 5: Not Installed 6: Degraded 11: Removed Syntax Integer Access Read-only Table 1628. Power Supply Severity Name powerSupplySeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1629. Power Supply 1 Part Number Name powerSupply1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1632. Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1633.
Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Table 1635. Power Supply Connection Table Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.10 Description Defines the power supply connection table.
Syntax Integer Access Read-only Table 1640. Power Supply Connection Enclosure Name Name powerSupplyConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this power supply belongs. Syntax DisplayString Access Read-only Table 1641. Power Supply Connection Enclosure Number Name powerSupplyConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
Syntax SEQUENCE OF TemperatureProbeEntry Access Not accessible Table 1644. Temperature Probe Entry Name temperatureProbeEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1 Description An entry in the Temperature Probe Table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax TemperatureProbeEntry Access Not accessible Index TemperatureProbeNumber Table 1645. Temperature Probe Number Name temperatureProbeNumber Object ID 1.3.6.1.4.1.674.
1: Ready 2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure Threshold Exceeded) 4: Offline 6: Degraded (Minimum Warning Threshold Exceeded, Maximum Warning Threshold Exceeded) 9: Inactive 21: Missing Syntax Integer Access Read-only Table 1649. Temperature Probe Severity Name temperatureProbeSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
Table 1653. Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 Description Identifies the maximum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Table 1654. Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 Description Identifies the maximum temperature that forces the probe into an error state.
Table 1657. Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.13 Description The status of the temperature probe itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1658. Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
Access Not accessible Index temperatureConnectionNumber Table 1661. Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry. Syntax Integer Access Read-only Table 1662. Temperature Probe Connection Temperature Probe Name Name temperatureConnectionTemperatureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
Access Read-only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system. The following object sets up the Enclosure Management Module Table. Table 1666. Enclosure Management Module Table Name enclosureManagementModuleTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.13 Description Defines the enclosure management module table. Syntax SEQUENCE OF EnclosureManagementModuleEntry Access Not accessible Table 1667.
Syntax DisplayString Access Read-only Table 1671. Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1672. Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.
Possible values: 0: Unknown 1: EMM 2: Termination Card Syntax Integer Access Read-only Table 1675. Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8 Description Identifies the firmware version of the enclosure memory module. Syntax DisplayString Access Read-only Table 1676. Enclosure Management Module Maximum Speed Name enclosureManagementModuleMaxSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Table 1678. Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 Description The status of the enclosure management module itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1679.
Access Not accessible Table 1682. Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry. Syntax EnclosureManagementModuleConnectionEntry Access Not accessible Index enclosureManagementModuleConnectionNumber Table 1683. Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.674.
Access Read-only Table 1687. Enclosure Management Module Connection Enclosure Number Name enclosureManagementModuleConnectionEnclosure Number Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs. Syntax Integer Access Read-only Battery Table This table describes available properties for each controller battery on the managed system.
Syntax DisplayString Access Read-only Table 1692. Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Table 1693. Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.4 Description Identifies the current state of battery.
3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1695. Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.6 Description The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1696.
Table 1698. Battery Nexus ID Name batteryNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.9 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Table 1699. Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity.
Syntax Integer Access Read-only Table 1702. Battery ID Name batteryID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.13 Description Represents unique id for battery. Syntax Integer Access Read-only Table 1703. Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14 Description The maximum amount of time (in hours) that the battery learn cycle can be delayed. Syntax Integer Access Read-only Table 1704.
Access Not accessible Table 1706. Battery Connection Entry Name batteryConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1 Description Defines the battery connection table entry. Syntax BatteryConnectionEntry Access BatteryConnectionEntry Index BatteryConnectionNumber Table 1707. Battery Connection Number Name batteryConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.1 Description Identifies the instance number of the battery connection entry.
Table 1711. Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.5 Description Identifies instance number of the controller in the controller table to which this battery belongs. Syntax Integer Access Read-only Tape Drive Table This table describes available properties for each tape drive on the managed system. The following object sets up the Tape Drive Table. Table 1712. Tape Drive Table Name tapeDriveTable Object ID 1.3.
Syntax DisplayString Access Read-only Table 1716. Tape Drive Vendor Name tapeDriveVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.3 Description The tape drive's manufacturer's name. Syntax DisplayString Access Read-only Table 1717. Tape Drive Product ID Name tapeDriveProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.4 Description The model number of the tape drive. Syntax DisplayString Access Read-only Table 1718.
Table 1721. Tape Drive Media Type Name tapeDriveMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.8 Description The Media type of the tape drive. Possible Values: 4: Tape Syntax INTEGER Access Read-only NVME adapter table This table describes available NVME adapter cards on the managed system. The number of entries is related to number of NVME Adapter cards discovered in the system. The following object sets up the NVME adapter Table. Table 1722.
Description The current state of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1726. NVME Adapter Controller Number Name nvmeAdapterControllerNum Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.3 Description The PCIeSSD subsystem Id to which the NVMe Adapter belongs to. Syntax INTEGER Access Read-only Table 1727. NVME Adapter PCI Slot Name nvmeAdapterPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.
Table 1731. NVME Adapter Serial Number Name nvmeAdapterSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.8 Description Product serial number of the NVMe Adapter. Syntax DisplayString Access Read-only Table 1732. NVME Adapter Revision Name nvmeAdapterRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.9 Description The NVMe Adapter revision. Syntax DisplayString Access Read-only Table 1733. NVME Adapter Driver Version Name nvmeAdapterDriverVersion Object ID 1.3.6.1.4.1.
Syntax INTEGER Access Read-only Table 1737. NVME Adapter Nexus ID Name nvmeAdapterNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.14 Description Nexus ID of the NVMe Adapter. Syntax DisplayString Access Read-only Table 1738. NVME Adapter Bus Protocol Type Name nvmeAdapterBusProtocolType Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.15 Description The Bus protocol for NVMe device: value: 9 (PCIeSSD) Syntax INTEGER Access Read-only Table 1739.
Description Number of bytes after total number of megabytes have been subtracted from the total size of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1742. NVME Adapter Device ID Name nvmeAdapterDeviceID Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.19 Description The device Id of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1743. NVME Adapter Model Number Name nvmeAdapterModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.
Table 1747. NVME Adapter Form Factor Name nvmeAdapterFormFactor Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.24 Description The form factor of the NVMe Adapter. Possible Values 2 : Card Syntax INTEGER Access Read-only Table 1748. NVME Adapter Supported Specification Name nvmeAdapterSupportedSpec Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.25 Description The NVMe specification supported by the device. Syntax DisplayString Access Read-only Table 1749.
Table 1752. NVME Adapter Available Spare Name nvmeAdapterAvailableSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.29 Description The remaining available spare space on the NVME device. Syntax INTEGER Access Read-only Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other.
Syntax INTEGER Access Read-only Table 1756. Virtual Disk Name Name virtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2 Description Identifies the virtual disk's label generated by Storage Management or entered by the user. Syntax DisplayString Access Read-only Table 1757. Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 Description Identifies the device name used by this virtual disk's member disks.
38: Resynching Paused 52: Permanently Degraded 54: Degraded Redundancy Syntax INTEGER Access Read-only Table 1759. Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax INTEGER Access Read-only Table 1760. Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Table 1763. Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1764. Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.10 Description Indicates whether the controller's write cache are used when writing to a virtual disk.
Table 1766. Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax INTEGER Access Read-only Table 1767. Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type.
Table 1771. Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 Description Unique ID for the virtual disk. Syntax INTEGER Access Read-only Table 1772. Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1773.
3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1775. Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Table 1776. Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Table 1778. Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 Description Indicates if virtual disk is encrypted. Value: 0 - No, 1 - Yes, 99 - Unknown Syntax INTEGER Access Read-only Table 1779. Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 Description Indicates if this virtual disk is configured as CacheCade.
Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum number of entries is implementationdependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF VirtualDiskPartitionEntry Access Not-Accessible Table 1783. Virtual Disk Partition Entry Name virtualDiskPartitionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.
Table 1787. Virtual Disk Partition Size Name virtualDiskPartitionSize Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4 Description Size of the partition in GB. Syntax INTEGER Access Read-only Table 1788. Virtual Disk Partition Nexus ID Name virtualDiskPartitionNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.6 Description Durable unique ID for this partition. This comprises the controllerID, virtualDisk ID and hash mapped WWN number of this partition.
Access Read-only Table 1792. Array Disk Logical Connection Array Disk Name Name arrayDiskLogicalConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2 Description Identifies the name of the array disk in this logical connection. Syntax DisplayString Access Read-only Table 1793. Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Table 1797. Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that are sent with SNMP traps. Table 1798. Message ID Event Name messageIDEvent Object ID 1.3.6.
Table 1802. Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.5 Description MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Table 1803. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1804. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Syntax DisplayString Access Read-only Table 1808. Service Tag Event Name serviceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.11 Description Service Tag of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1809. Chassis Service Tag Event Name chassisServiceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.12 Description Chassis Service Tag of object causing the alert if applicable.
4 Change Management Group The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM package must be installed for Dell OpenManage Server Administrator to respond to SNMP queries in this group. See the Server Administrator Installation Guide for more information.
Table 1813. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1814. Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Table 1815. Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.1 Description Defines the unique index for this device.
Table 1819. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Table 1820. Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Table 1821. Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Access Read-only Table 1824. Application Index Name aplicationIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.1 Description Defines the unique index for this application. Syntax Unsigned16BitRange Access Read-only Table 1825. Application Device Index Name applicationDeviceIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.2 Description Defines a cross-index to the device table for the application. Syntax Unsigned16BitRange Access Read-only Table 1826.
Access Read-only Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Inventory Collector Product Information The following objects describe the fields for the Inventory Collector.
5 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 1831. Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Table 1832. Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
Table 1837. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 1838. Service Tag Variable Name alertServiceTag Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9 Description Specifies the system service tag of the system generating the alert. Syntax DisplayString Table 1839. Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.
Description Line Item Explanation Chassis location: Specifies the name of the chassis that generated the message, for example: Chassis location: Main System Chassis Configuration error type: Specifies the type of configuration error that occurred, for example: Configuration error type: Revision mismatch Current sensor value (in Amps): Specifies the current sensor value in amps, for example: Current sensor value: 7.
Description Line Item Explanation Possible memory module event cause: Specifies a list of possible causes for the memory module event, for example: Possible memory module event cause: Single bit warning error rate exceeded Single bit error logging disabled Power Supply type: Specifies the type of power supply, for example: Power Supply type: VRM Pre-failure state was: Specifies the status of the previous memory message, for example: Pre-failure state wa
• Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as crossing a failure threshold or a hardware failure. BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds. All the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1. Table 1841.
TrapID Description Severity 131840 Generic Critical Voltage Problem Cleared Information 356096 Chassis Intrusion - Physical Security Violation Critical 356224 Chassis Intrusion (Physical Security Violation) Event Cleared Information 262400 Generic Predictive Fan Failure (predictive failure asserted) Minor 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 264962 Fan redundancy
TrapID Description Severity 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cleared Information 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Information 789249 Memory Redundancy has been Lost Critical 789248 Me
6 Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional. For example, a Warning/Non-critical alert may indicate that a component (such as a temperature probe in an enclosure) has crossed a warning threshold. Critical/Failure/Error A component has either failed or failure is imminent. This alert indicates a serious problem such as data loss or a loss of function.
Table 1844. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Table 1845. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Table 1846.
Syntax DellStatus Access Read-only Table 1850. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable. Syntax DellStatus Access Read-only The following table shows the new enhanced mode varbinds which would be available in the EEMI where the user can get both Traditional and Enhanced varbinds : Table 1851. Enhanced Message ID Event Name enhancedMessageIDEvent Object ID 1.3.6.1.4.1.674.
Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. These traps are defined in the Storage Management MIB. These traps correspond to the alerts documented in the Alert Descriptions and Corrective Actions section. For more information on the MIB and its structure, as well as a change history of the SNMP traps, see the Introduction section.
7 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 1857. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown. enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant. degraded(4) The object’s redundancy has been degraded. lost(5) The object’s redundancy has been lost. notRedundant(6) Redundancy does not apply or it is not redundant. Table 1861.
The values are zero-padded, and if a valid value for a field is not deliverable, each character in the field is replaced with an asterisk (*) character.
8 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
'\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 = '\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03' 1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2 1.3.6.1.4.1.